Create an account and get 3 free clips per day.
Chapters
Obstruction of Choledochocele|Obstruction of Choledochocele|71|Female
Obstruction of Choledochocele|Obstruction of Choledochocele|71|Female
2016biliarybilirubinbowelcatheterdrainageductendoscopicfunctionalmodifiedobstructionoccludedocclusiononcologistspancreaticpercutaneouspericatheterSIRstentedvarices
Intraop Completion Control Study by Duplex or Angiography is a MUST After CEA
Intraop Completion Control Study by Duplex or Angiography is a MUST After CEA
authorscarotidCASCEAclinicalcompletioncrestdatadecreasediagnosticduplexendarterectomyindicationsintraoperativemanuscriptmonitoringmultivariateneurologicpatientsrandomizedrateselectiveshuntstrokestudyunivariatevascular
Advantages Of Cook Zenith Spiral Z Limbs For EVARs Landing In The External Iliac Artery
Advantages Of Cook Zenith Spiral Z Limbs For EVARs Landing In The External Iliac Artery
aneurysmarterybuttockclaudicationCook ZenithdeployedendograftendoleaksevarevarsexcellentfinalgrafthelicalhypogastriciliacjapaneselandinglimbobservationalocclusionoperativepatencypatientspercentrenalrequiredspiralSpiral Z graftstenosisstentStent graftstentsstudytripleVeithzenith
How Can Duplex Ultrasound Reliably Predict Stent Thrombosis Before It Occurs And Improve Results
How Can Duplex Ultrasound Reliably Predict Stent Thrombosis Before It Occurs And Improve Results
abnormalcontroversialdiagnosticduplexendovascularextremityfempopfollowiliacinterveneoccludedocclusionpatencyperipheralprostheticproximalstenosisstentstentedstentsSurveillancesystolicveinvelocities
Value And Limitations Of Cryopreserved Allografts For The Treatment Of Arterial Prosthetic Graft Infections
Value And Limitations Of Cryopreserved Allografts For The Treatment Of Arterial Prosthetic Graft Infections
adjunctiveaneurysmaorticarterialautologousbleedingcellulitisclosurecomplicationcomplicationsCryopreserved Allograftdeviceetiologyextremityfemoralgraftinfectedinfectioninfectionsinfectiousintraoperativelateligationlimbmycoticpatientspercutaneousperipheralprimaryprofundaprostheticpseudoaneurysmpseudoaneurysmsresectionscanseedingstenttherapeutictreatedulceratedvisceral
DEBATE: All SFA Lesions Can Be Treated Endovascularly: Should They Be: Open Bypass Should Rarely Be Used
DEBATE: All SFA Lesions Can Be Treated Endovascularly: Should They Be: Open Bypass Should Rarely Be Used
AbbottangiogramballooncanalizationdiameterendovascularevarfemoropoplitealhematomaintroducerlesionsocclusionpatencyperformPeripheral stent systempoplitealpunctureretrogradestentsubintimalSuperatechniquetherapeuticthrombosistotaltreatVeith
Value Of Transcranial Doppler In Improving Results Of Transcatheter Aortic Valve Implantation (TAVI)
Value Of Transcranial Doppler In Improving Results Of Transcatheter Aortic Valve Implantation (TAVI)
angioarchballoonBAVbilateralbraincerebralcontrastcrossingdeploymentdiagnosticdiastolicdoppleremboliembolusflowhypoperfusioninjectionlowmicroembolimicroembolizationoccludedocclusionplacementsignalsTAVRtoolTranscatheter Aortic Valve Implantation (TAVI)transcranialvalvewaveform
Endoscopic vs. Open Vein Harvest For Bypasses: What Are The Advantages And Disadvantages Of Each
Endoscopic vs. Open Vein Harvest For Bypasses: What Are The Advantages And Disadvantages Of Each
advantagesautologousbypasscardiaccomorbidcomplicationsdecreasedecreaseddisadvantagesendoscopicendovascularextremityharvestincisionincreasedinexperiencedlaborligatedlowerpatencypatientspercutaneousperformedprimaryrisksaphenoussurgicalsuturevascularveinVeithwoundwounds
Status Of Dual Layer Stents For CAS: Is Acute Occlusion An Issue And How To Avoid It
Status Of Dual Layer Stents For CAS: Is Acute Occlusion An Issue And How To Avoid It
acuteadequateantiplateletappositionarterybridgingcarotidcarotid stentcerebrovascularclopidogreldeploymentdualhighlightintravenouslylayermaneuvermeaningmedicationobservedocclusionpatientpatientsperformedporepredisposingpreparationpublicationsRoadSaverstenosisstentstentingstrokeTerumo interventional systemstherapythrombogenicthrombogenicityVeithwallstent
New Devices For False Lumen Obliteration With TBADs: Indications And Results
New Devices For False Lumen Obliteration With TBADs: Indications And Results
aneurysmangiographyaortaballooningCcentimeterdilatorendograftendovascularEndovascular DevicefenestratedgraftiliacimplantedlumenoccludeoccluderoccludersoccludesremodelingstentStent graftstentstechniqueTEVARtherapeuticthoracicthoracoabdominalVeithy-plugyplug
What Are The Complications Of Spinal Fluid Drainage: How Can They Be Prevented: Optimal Strategies For Preventing Or Minimizing SCI
What Are The Complications Of Spinal Fluid Drainage: How Can They Be Prevented: Optimal Strategies For Preventing Or Minimizing SCI
aneurysmAneurysm repairaxisBEVARceliacchronicDialysisdraindrainagedrainseliminatedextentFEVARflowFluid / PressorsheadachehematomahemorrhagehypotensionincludingintracranialOccluded SMAoutcomespalliativeparaplegiapatientpatientsplacementpostoperativeprolongedprospectiveprotocolratesevereSevere PancreatitisspinalTEVARtherapeutictreated
Histology of In-stent Stenosis
Histology of In-stent Stenosis
angioplastiedangioplastyAnti-platelet therapyanticoagulationascendingbiopsyBoston ScientificcalcificationcontrastdiffuseDiffuse severe in-stent stenosisEndoprosthesisextendingfemoralfollowupfreshhistologyiliacintimalmaximalnitinolocclusionorganizingoutflowoverlappingpoplitealPost- thrombotic SyndromePTArecanalizationreliningRelining with WallstentsstenosisstentstentingstentssuperficialTherapeutic / DiagnosticthickeningthrombolysisthrombustimelineVeithvenogramwallstentwallstents
Surgical vs. Endovascular Management Of Cephalic Arch Syndrome
Surgical vs. Endovascular Management Of Cephalic Arch Syndrome
adjunctsanatomicangioplastyarchballoonballoonsbrachiocephaliccephalicdeploymentfistulasfunctionalgoregraftgraftingInterventionspatencypredictorsprimaryradiocephalicrecurrentstenosesstenosisstentStent graftstentingsuperiorsurgicaltranspositionviabahn
What Morphological Changes On CT After EVAR Predict The Need For Re-Interventions: From The DREAM Trial
What Morphological Changes On CT After EVAR Predict The Need For Re-Interventions: From The DREAM Trial
analysisaneurysmangulationaorticdiameterendograftendoleakendoleaksendovascularevariliaclengthlimbmaximalneckpatientspredictpredictivepredictspreoperativeproximalreinterventionsscanssecondaryshrinkagestenosisstenttherapeuticthrombus
Technical Issues And Experience With MIS2ACE In 50 Patients Undergoing Endo TAAA Repair
Technical Issues And Experience With MIS2ACE In 50 Patients Undergoing Endo TAAA Repair
aneurysmanterioraorticarterycoilcoilingcoilscollateralcordembolizationischemicMIS²ACEocclusionPatentpatientperformsegmentalspinalstenotictechniquetherapeuticthoracoabdominal
Sandwich Technique For Treating AAAs Involving The Common Iliac Bifurcations: Experience With 151 Hypogastric Revascularizations: Lessons Learned
Sandwich Technique For Treating AAAs Involving The Common Iliac Bifurcations: Experience With 151 Hypogastric Revascularizations: Lessons Learned
aneurysmarterybrachialcathetercentimeterclaudicationcomorbiditycomplicationsdiameterendograftendoleaksgorehypogastriciliaciliac arteryischemialatexlimblumenmajoritymidtermmortalityocclusionorthostaticpatientsperformedreinterventionrevascularizationssandwichstenttechniquetherapeutictreattypeviabahnwish Technique
Cloud Based System For Image Fusion Techniques With Mobile C-Arms (The Cydar System): How Does It Work And Advantages For All Vascular Interventions
Cloud Based System For Image Fusion Techniques With Mobile C-Arms (The Cydar System): How Does It Work And Advantages For All Vascular Interventions
anatomyaorticaortoiliacAortoiliac occlusive diseasebasedBilateral Kissing StentsbodiesclinicalcontrastCydar EV (Cydar Medical) - Cloud SoftwaredecreasesderivedendovascularevarFEVARfluorofluoroscopyfusionhardwarehybridiliacimageimagesimagingmechanicaloverlaypatientpostureprocedureproximalqualityradiationreductionscanstandardstatisticallytechnologyTEVARTherapeutic / DiagnostictrackingvertebralZiehm ImagingZiehm RFD C-arm
Optimal Anticoagulation Regimen For Patients Being Treated For ALI
Optimal Anticoagulation Regimen For Patients Being Treated For ALI
acuteangioplastyanticoagulationaspirinatrialbleedingcategoryclinicalcomorbiditiesefficacyembolismextremityguidelinesheparininfrainguinalintraopintravenousischemiaischemiclimbminoritypatientsperformedpostopproximalrecurrentregardreperfusionstablestentingsystemictherapeuticthrombosisunderwentunfractionatedvascularVeithversusvitamin
Status Of Aortic Endografts For Occlusive Disease: Indications, Precautions, Technical Tips And Value
Status Of Aortic Endografts For Occlusive Disease: Indications, Precautions, Technical Tips And Value
abisaccessacuteAFX ProthesisantegradeanterioraortaaorticaortoiliacarteriogramarteryaxillaryballoonbrachialcalcifiedcannulationcircumferentialcutdowndilatordiseasedistallyendarterectomyEndo-graftendograftendograftsEndologixexcluderExcluder Prothesis (W.L.Gore)expandableextremityfemoralfemoral arterygraftiliacintimallesionslimboccludeoccludedocclusionocclusiveOpen StentoperativeoptimizedoutflowpatencypatientspercutaneouspercutaneouslyplacementpredilationproximalrequireriskRt CFA primary repair / Lt CFA Mynx Closure devicesheathstentstentssymptomstasctechnicaltherapeuticvessels
Improper And Suboptimal Antiplatelet Treatment Casts Doubt On All CAS Trials: What Are The Implications
Improper And Suboptimal Antiplatelet Treatment Casts Doubt On All CAS Trials: What Are The Implications
accessactiveangioplastyantiplateletaspirincarotidCASconvertcrestdatadecreaseembolicendarterectomyenzymeeventsgroininsertintermediatelivermetabolitenormalpackagepatientspeopleplavixpoorrandomizedrapidriskshiftsitestentstentingstentstechnicaltrialsultra
VICI Stent Trial Update
VICI Stent Trial Update
acuteBoston ScientificchronicdefinitionsdifferencesDVTendpointfeasibilityinclusioning Stent / Venovo (Bard Medical) - Venous Stent System / Abre (Medtronic) - Venous Self-Exping Stent SystemivusnitinolocclusionocclusionspatencypatientspivotalproximalstenttermstherapeuticthrombotictrialsvenousVenous Stent SystemViciZilver Vena (Cook Medical) - Venous Self-Exp
Why Are Carotid Stenoses Under- And Over-Estimated By Duplex Ultrasonography: How To Prevent These Problems
Why Are Carotid Stenoses Under- And Over-Estimated By Duplex Ultrasonography: How To Prevent These Problems
arteriovenousbasicallybrachiocephaliccarotidcommoncontralateraldiameterdiscordancedistalexternalFistulainternallowoccludedocclusionproximalrecanalizedrokestenosistighttumorvelocitiesvelocityvessel
Single Branch Carotid Ch/TEVAR With Cervical Bypasses: A Simple Solution For Some Complex Aortic Arch Lesions: Technical Tips And Results
Single Branch Carotid Ch/TEVAR With Cervical Bypasses: A Simple Solution For Some Complex Aortic Arch Lesions: Technical Tips And Results
accessaccurateaorticarcharterycarotidcarotid arteryCarotid ChimneychallengingchimneyChimney graftcommoncommonlycoveragedeployeddeploymentdevicedissectionselectiveembolizationemergentlyendograftendoleakendovascularexpandableleftmaximummorbidityocclusionpatientsperformedpersistentpublicationsretrogradesealsheathstentssubclaviansupraclavicularTEVARtherapeuticthoracictype
How Can Medical Holograms And 3D Imaging Be Helpful During Endovascular Procedures
How Can Medical Holograms And 3D Imaging Be Helpful During Endovascular Procedures
3D medical imagingaortaaugmentedcardiaccatheterCoreValve (Medtronic) - Transcatheter Aortic Valve Delivery Catheter System / TAVIguide (FEops) - Simulation technology / Holoscope (RealView Imaging) - 3D medical imagingDigital Light ShapingdynamicfloatingfocalfocusinteractmitralneedlepatientRealView ImagingsliceTherapeutic / DiagnosticvalveVeith
Value Of Intraprocedural Completion Cone Beam CT After Standard EVARs And Complex EVARs (F/B/EVARs): What To Do If One Does Not Have The Technology
Value Of Intraprocedural Completion Cone Beam CT After Standard EVARs And Complex EVARs (F/B/EVARs): What To Do If One Does Not Have The Technology
4-Vessel FEVARangiographyaortoiliacarchaxialbeamBEVARbifurcatedcalcificationcatheterizecatheterizedcompletionconecone beamcoronaldetectablediagnosticdilatordissectionDissection FlapendoleakevaluatesevarfemorofenestratedFEVARfindingsfusionGE HealthcareinterventionmesentericocclusionoperativelypositiveproceduresprospectiveproximalradiationRadiocontrast agentrotationalstentstudytechnicalthoracoabdominaltriggeredunnecessaryVisipaque
With Complex AAAs, How To Make Decisions Re Fenestrations vs. Branches: Which Bridging Branch Endografts Are Best
With Complex AAAs, How To Make Decisions Re Fenestrations vs. Branches: Which Bridging Branch Endografts Are Best
anatomicanatomyaneurysmaneurysmsaorticarteriesballoonBARDBEVARbranchbranchedbranchesceliaccenterscombinationCoveracovereddeviceendovascularexpandableextremityfenestratedFenestrated EndograftfenestrationfenestrationsFEVARincidencemayoocclusionocclusionsphenotypeproximalproximallyrenalrenal arteriesrenalsreproduciblestentstentstechnicaltherapeutictortuositytypeversusViabah (Gore) / VBX (Gore) / Bentely (Bentely)visceral
Single Session Continuous Aspiration Thrombectomy (SSCAT) For All DVT Utilizing Indigo Thrombectomy System
Single Session Continuous Aspiration Thrombectomy (SSCAT) For All DVT Utilizing Indigo Thrombectomy System
Angiojet Power Plus CatheterantegradeaspirationcatheterdaviesdeviceFinal Indigo + Lytics + Wall Stent +Indigo Aspiration System Devices (Pneumbra)Lt Ilio-Femoral DVTlyticsmaximaloccludedPower Pulse Spray Techniquethrombectomyunderlyingutilizedvenous
Technical Tips For The Management Of Cervical And Mediastinal Iatrogenic Artery Injuries: How To Avoid Disasters
Technical Tips For The Management Of Cervical And Mediastinal Iatrogenic Artery Injuries: How To Avoid Disasters
9F Sheath in Lt SCAAbbottaccessarterybrachialcarotidcatheterCordisDual Access (Rt Femora + SC sheath) ttt with suture mediated proglid over 0.035 inch wireendovascularfemoralfrenchgraftiatrogenicimaginginjuriesleftPer-Close suture mediated ProgliderangingsheathstentsubclaviantreatedvarietyvascularvenousvertebralVessel Closure Devicewire
Estimation Of Long-Term Aortic Risk After EVAR: The LEAR Model: How Can It Guide And Modulate Surveillance Protocols
Estimation Of Long-Term Aortic Risk After EVAR: The LEAR Model: How Can It Guide And Modulate Surveillance Protocols
aneurysmaorticcentimeterdeviceendoleaksevarlearlowoutcomespatientpatientspredictorsregulatoryriskshrinkagestentsuprarenalSurveillanceVeith
Results Of A Multicenter Italian Registry Of Real World CAS With The C-Guard Mesh Covered Stent: The IRONGUARD 2 Study
Results Of A Multicenter Italian Registry Of Real World CAS With The C-Guard Mesh Covered Stent: The IRONGUARD 2 Study
brachialC-GuardcarotidCASCovered stentcumulativedemographicdeviceembolicembolic protection deviceenrolledexternalInspire MDminormyocardialneurologicneurologicalocclusionongoingpatientsproximalratestenosisstenttiastranscervicaltransfemoral
Importance Of Maintaining Or Restoring Deep Femoral Artery Flow In Open And Endo Revascularizations For CLTI
Importance Of Maintaining Or Restoring Deep Femoral Artery Flow In Open And Endo Revascularizations For CLTI
amputationangioplastyarteryballoonclaudicationcombinedconfigurationsdeependovascularextremityfemoralfemoral arterygroinhealhybridiliacinflowinfrainguinalischemicisolatedlimbocclusionOcclusion of DFApainpatencypatientpercutaneousperfusionpoplitealpreventprofundaproximalrestrevascularizesalvageseromastenosisstentingstumpsystemictransluminaltreatableVeithwound
Transcript

So here is our case.This is a 71-year-old woman whose it's, Marge. Her bilirubin is 12.5

She's pruritic and with the bilirubin at 12.5 she's unable to get the chemotherapy that the oncologists wants to give her for her pancreatic cancer, she had an endoscopic biopsy of her pancreatic neck masks at the outside hospital positive for adenocarcinoma, and you can see some interesting features here in addition to the

masks, she has numerous varices. See all these varices around the duct here. And she has this cystic protrusion of the duct into the duodenum which is representative of a choledochocele. Now this varices were the reason that our endoscopist declined to intervene on this case.

So she came for percutaneous drainage and these are some images from here initial drainage which correlate very well with the CT images. You can see here a short segment occlusion of the common duct, a choledochocele and again this is the initial drainage picture you can see

doctors occluded mid duct. This is the catheter that we left and basically this is sort of a stylized picture of the catheter. And this is a modified dose dorsal/g miller catheter which we placed to help us assess for functional obstruction of the choledochocele. So we weren't sure it's clear that this is a functional obstruction

but the question is, is this a second level of obstruction? So that intellectually we thought, she's lived 70 years or some period of time with the choledochocele and she hasn't presented with biliary obstruction till now.

I wonder, so we wanted to find a way of testing to see what the story was so we placed this modified catheter with side holes above and below the occlusion here but outside of the bowel, and what we did is after we let it drain for a little bit for the apparatus/g to resolve and for the bowel to clear then we capped it.

Unfortunately it turned out that she failed the capping trial, she developed abdominal pain, she had some pericatheter leakage. We chose to interpret that as being consistent with a functional obstruction at the level of the choledochocele,

we probably could have tried another capping trial but she ended up getting stented in the bowel sort of to facilitate her moving along with her current treatment. And her bilirubin normalized. So again I'm just gonna use this as sort of a starting off point to talk

- So again, I'd like to thank Dr. Veith for the opportunity to participate in this interesting debate. So, I have been tasked with the position Intra-operative Completion Study is not mandatory, and in fact I will show you why a selective approach will actually provide better results for our patients. These are my disclosures related to ongoing

clinical research and clinical trials. So again, Professor Eckstein and his colleagues should be very significantly commended for getting the entire German vascular surgery community to look at their data in a very rigorous fashion. However, both he and his co-authors will acknowledge

within the manuscript that there are significant problems with this database. A very large number of 142,000 elective carotid endarterectomy procedures with very ballotable stroke and death rates of 1.4 and 2.5%. However, a typical criticism from outside the

vascular surgery community, these are all self-reported. These are not 30 day outcomes, they're actually in-hospital outcomes. And while in Germany that still may be four days, it's not the 30 days that we see. I'll show you a little bit later on within the Crest data.

And interestingly, within their own manuscript only 50% of the patients actually had neurologic assessment both pre- and post-procedural. So, how can we make a relevant decision in terms of thinking about how we're going to treat these patients if we only have neuro data on half of them.

Lets for the moment assume we can call out those patients. How does this relate to clinical practice? Well the authors also admit that this is an observational study, and that even though there is some association, there clearly is no causal relationship

as my previous debater just admitted. And in fact, they argue that this is perhaps the best method to look at generating hypotheses for future randomized trials, much like Dr. Aborama has done with the use of carotid endarterectomy with patching. So, let's look a little bit more about the data

and see how relevant it is to your current practice. So in the Germany registry, a quarter of the patients are treated under local anesthetic. 40% have no type of neurologic monitoring, and over 40% are performed with aversion endarterectomy. Very, very different than the practice that we see

in our institution, and in the New England region. And I would argue that there's a lot of concern in terms of what the indications are for monitoring, what the indications are for shunt use. Again, that's 43%. But there's absolutely no data in this registry about

indications for shunting, when it was used, or when patients were re-explored and what they found at the time. And a little bit concerning is in 17% of the patients, there was no anti-platelet agent used in patients undergoing carotid endarterectomy.

And, I would argue that that number is just a little bit high. How about when we go to the univariate analysis? Once again, we see that there's a benefit of 0.4% decrease in stroke and death for a local anesthetic, although we are well aware that there are numerous other

perspectives that have looked at this and not shown that same relationship. Again, there's a benefit for aversion endarterectomy, but I would argue at least in the New England region and perhaps in the United States except for select centers, aversion endarterectomy is used the minority of the time

and that in fact is an indication in my mind to have a lower threshold for either angiogram or completion duplex. Most concerning, there was 0.3% difference in the stroke and death rate with the lack of an intraoperative completion study, but there was no data about indications, findings,

whether that resulted in an intervention, or what the result of that intervention was. And initially in the univariate analysis, neuro-psyche, physiologic monitoring was protective, but later on in the multivariate, it was not. Here is that same multivariate analysis that shows again

that in fact shunting and neuro-physiologic monitoring are increased risk factors for stroke. Certainly there's going to be some bias. My concern is I'm not convinced the authors are able to call out the co founding variables, even in their multivariate regression analysis.

And in fact, in their concluding paragraphs they state there's no information supplied on whether intraoperative completion studies caused an operative revision or not, and no information about cause of death. In fact, they don't even have information about

intraoperative heparin or protamine application. So I would argue I'd be very skeptical about making my final decisions based on this. Thinking about the technical aspects of angiography, there's no doubt that this is very helpful at times, but think about the details of where do you put the needle.

What type of imaging? Is it a C-arm, is it a flat plate? Who interprets it, and what are your thresholds for intervention? So, it certainly may be harmful, may be unnecessary, and may even give you false positives.

Similarly with Completion Duplex studies, there certainly is a false positive rate and then there's risk for re-clamping. I reached out to my friend and colleague Braglol to see if there was any data from Crest that would help us, and unfortunately other than the fact that stroke happens

up to 30 days after our initial endarterectomy, there was no data supporting that. So, perhaps the best study that we have is our current practice in New England where we had 6,000 patients, a third of whom received completion studies. We broke this down into rare, selective, and routine

duplex or angio studies. And in fact, in the selective group we had a very low rate of re-exploration versus the other group, and a much lower incidence of overall stroke and death. In fact, the only benefit that was statistically significant was a decrease one year rate of re-stenosis.

So in conclusion, I would argue that this is probably unnecessary, and in fact maybe harmful. Meticulous technique, intra-procedural monitoring with selective shunt use, and continuous wave doppler use may, in fact, be the way to go. But this does give us an opportunity for prospective,

randomized trial as part of another study to look for completion study indications. Thank you very much.

- Thank you, Ulrich. Before I begin my presentation, I'd like to thank Dr. Veith so kindly, for this invitation. These are my disclosures and my friends. I think everyone knows that the Zenith stent graft has a safe and durable results update 14 years. And I think it's also known that the Zenith stent graft

had such good shrinkage, compared to the other stent grafts. However, when we ask Japanese physicians about the image of Zenith stent graft, we always think of the demo version. This is because we had the original Zenith in for a long time. It was associated with frequent limb occlusion due to

the kinking of Z stent. That's why the Spiral Z stent graft came out with the helical configuration. When you compare the inner lumen of the stent graft, it's smooth, it doesn't have kink. However, when we look at the evidence, we don't see much positive studies in literature.

The only study we found was done by Stephan Haulon. He did the study inviting 50 consecutive triple A patients treated with Zenith LP and Spiral Z stent graft. And he did two cases using a two iliac stent and in six months, all Spiral Z limb were patent. On the other hand, when you look at the iliac arteries

in Asians, you probably have the toughest anatomy to perform EVARs and TEVARs because of the small diameter, calcification, and tortuosity. So this is the critical question that we had. How will a Spiral Z stent graft perform in Japanese EIA landing cases, which are probably the toughest cases?

And this is what we did. We did a multi-institutional prospective observational study for Zenith Spiral Z stent graft, deployed in EIA. We enrolled patients from June 2017 to November 2017. We targeted 50 cases. This was not an industry-sponsored study.

So we asked for friends to participate, and in the end, we had 24 hospitals from all over Japan participate in this trial. And the board collected 65 patients, a total of 74 limbs, and these are the results. This slide shows patient demographics. Mean age of 77,

80 percent were male, and mean triple A diameter was 52. And all these qualities are similar to other's reporting in these kinds of trials. And these are the operative details. The reason for EIA landing was, 60 percent had Common Iliac Artery Aneurysm.

12 percent had Hypogastric Artery Aneurysm. And 24 percent had inadequate CIA, meaning short CIA or CIA with thrombosis. Outside IFU was observed in 24.6 percent of patients. And because we did fermoral cutdowns, mean operative time was long, around three hours.

One thing to note is that we Japanese have high instance of Type IV at the final angio, and in our study we had 43 percent of Type IV endoleaks at the final angio. Other things to notice is that, out of 74 limbs, 11 limbs had bare metal stents placed at the end of the procedure.

All patients finished a six month follow-up. And this is the result. Only one stenosis required PTA, so the six months limb potency was 98.6 percent. Excellent. And this is the six month result again. Again the primary patency was excellent with 98.6 percent. We had two major adverse events.

One was a renal artery stenosis that required PTRS and one was renal stenosis that required PTA. For the Type IV index we also have a final angio. They all disappeared without any clinical effect. Also, the buttock claudication was absorbed in 24 percent of patients at one month, but decreased

to 9.5 percent at six months. There was no aneurysm sac growth and there was no mortality during the study period. So, this is my take home message, ladies and gentlemen. At six months, Zenith Spiral Z stent graft deployed in EIA was associated with excellent primary patency

and low rate of buttock claudication. So we have most of the patients finish a 12 month follow-up and we are expecting excellent results. And we are hoping to present this later this year. - [Host] Thank you.

- Yeah, thank you Dr. Asher, and again, I want to give credit to Dr. Zheng, one of our fellows who put together this work. So duplex surveillance for lower extremity revascularization, I think we all do that for vein grafts. It's less well accepted for prosthetic grafts. It's controversial for peripheral stent grafts,

and it's very controversial for peripheral stents. If we had time, I'd like to poll all of you and ask how many of you do a duplex scan after you put in a peripheral arterial stent, but more importantly, how many would intervene if you find the velocities are increasing.

So why do it? Well, revision of failing stents may yield better patency rates than if you intervene after the stent has occluded. You may not be able to restore patency if the stent has already occluded, I mean,

some of you may think you can always do that, I know I can't always do that. And performing endovascular treatment is obviously easier than converting to open surgery. So we reviewed 172 stents in 30 iliac and 89 fempop arteries.

Some were overlapping stents, so we kind of said there were 119 segments that we analyzed. The treated length for the iliac artery was about seven and a half centimeters, and for fempop, was about 12 centimeters. And we did duplex surveillance

in our accredited vascular lab in our office. We measured the peak systolic velocity, and the PSV ratios, every two centimeters within the stent but also in the adjacent proximal and distal arteries. We considered it an abnormal duplex finding, I think pretty much consistent

with what you would do for a vein graft, also, if you had a focal PSV over 300, uniform PSVs throughout the stent less than 45, or a ratio more than three, we would say that probably corresponds with more than a 75% stenosis

and generally we would intervene. We did the duplex one week after we put in a peripheral stent, and then about every six months. The follow up averaged about two years. So of these 119 stented segments, about half of 'em stayed normal.

All of the duplex criteria stayed normal during the entire follow up, nothing needed to be done. But interestingly, of the other half, they developed at least one abnormal duplex criterion. 40 of the 57 cases we intervened on, but of the 17 other cases we did not intervene,

either due to patient refusal, or the surgeon felt, well, let's just keep an eye on it, five did remain patent for a short follow up, but 12 of the 17 went on to occlude. Of the 12 occluded segments, we found that if there was more than one

abnormal duplex finding and you did not treat, 70%, again the numbers are small, but 70% occluded, compared to if you had the normal duplex findings, only 3% occluded, and this was highly significant. So of the 12 occluded stents, what happened? Well six we didn't do anything,

they were just for claudication, and the patients chose not to have open surgery. But four, we did try to open 'em and could not, and they needed a bypass, mainly for limb salvage. But two, we couldn't do anything, and they ended up with amputations.

So the bottom line in this relatively small series was if a stent occluded, they didn't necessarily do well and you couldn't open 'em up. So in conclusion, duplex surveillance for lower extremity stents, and that's what we're talking about,

can significantly predict stent occlusion based on these criteria, and the absence of any criteria strongly predicted stent patency. We even have a little disagreement, frankly, in my own group about how aggressive to be for these.

I tend to be pretty aggressive and intervene. Maybe during the discussion we can talk about this. Thank you.

- So I'm going to be talking about allografts for peripheral graft infections. This is a femoral artery that's been replaced after a closure device infection and complication, and we've bypassed to the SFA and profunda femoris. These are my disclosures. So peripheral arterial infectious processes,

well the etiology either is primary or secondary. Primary can be from bacteremic states and seeding of ulcerated plaque or thrombus. Secondary reasons for infections can be the vast usage of percutaneous closure devices that really have flooded the market these days.

Prosthetic graft infections after either a bypass or patch in the femoral artery. So early onset infections usually are from break in sterility. Secondary infections can be from either wound breakdowns or late seeding of the prosthetic graft.

The presentation for these patients can be relatively minor such as cellulitis or draining sinus, or much more dramatic, such as sepsis or pseudoaneurysm or mycotic aneurysm. On the CT scan we can see infected mycotic aneurysm after infected closure device and bleeding complications.

The treatment is broad in range. Ligation is obviously one option, but it leads to a very high risk of major limb amputation. So ideally some form of reconstruction, either extra-anatomic through clean planes,

antibiotic graft as we heard from the previous speaker, the use of autologous replacement with deep vein, or we become big proponents of the use of cryopreserved arterial allografts for reconstruction. And much of this stems from our work from about 10 years ago, where we looked

at the use of aortic cryopreserved grafts for aortic graft infections. This was published about 10 years ago but we looked at a small series of patients with aortic infections. You can see the CT scan of an infected stent graft

and associated aneurysm. And then the intraoperative photo after we've resected the stent graft and replaced that segment of the aorta with a cryopreserved aortic segment. So using that as a springboard,

we then decided to look at the outcomes using these types of conduits, arterial conduits, for peripheral arterial reconstructions in contaminated or infected surgical fields. So retrospective review at our tertiary care center, we looked at roughly 60 patients over a 15-year period

and excluded any aortic-based reconstructions. So these are all peripheral reconstructions. Mean follow-up was 28 months. As you would expect, the distribution of treatment zones were primarily in the lower extremities, so 51 cases.

As you can see, there's a list of all the different types of cases that we treated. But then there were a few upper extremity visceral and then carotid. I've shown this slide before at this meeting in the past, with a carotid patch infection

that was treated after it had a blow-out, and it's obviously a infected aneurysm, and this was treated with resection and a cryopreserved arterial segment. Looking at our outcomes, the 30-day outcome showed a mortality rate of 9%.

The 30-day conduit-related complication rate was surprisingly low at 14%. We had four patients that had bleeding complications, four patients with recurrent infectious complications. All eight of those patients required a return back to the operating room for correction.

The late conduit-related complication rate was only 16%. As listed here, you can see there's only one case of reinfection, three cases of graft thrombosis, surprisingly only one major limb amputation, two pseudoaneurysms and one late bleeding complication.

And graphically depicted, you can see here, this area here is looking at the less than 30 days, this is primarily when the complications occur. When you get to six months, fewer complications, and then beyond six months, the primary complications that we would see are either thrombosis of the graft

or the development of late pseudoaneurysms, again relatively low. So in summary, I think peripheral arterial infectious complications can be treated with a cryopreserved arterial allografts. The advantage is it's a single stage operation,

maintains in-line flow, there's a low incidence of repeat infection. I think it's also important to mention that the majority of these patients had adjunctive muscle flap coverage to cover the large soft tissue defect

at the time of the operation. So I think that this is a valuable alternative conduit in a setting of peripheral arterial infections. Thank you.

- Thank you very much, Mr. Chairman. Thank you Frank Veith for the invitation, talking about, "SFA lesions can be treated endovascularly: "Should they be?" I do not have any potential conflict of interest for this presentation, and I would like to share with you. We have two ways: Is it technically feasible

to perform always reverse canalization by endovascular technique, and the SFA, and should we do it? And I would like to immediately conclude by it's possible for me to treat all the lesions by endovascular technique in the SFA and popliteal lesion, and for me, I think, for us it's always the first choice.

So, next: What we do to really need an SFA re-canalization and a SFA repair? To be well armed with guides and catheter to perform re-canalization, and it's necessary how to get by unusual ways:

retrograde puncture of each over. And the difficulty is to know if we perform subintimal re-canalization or not, and the success of this technique is always the reentry. So for me, I think it's very important to have a right and clear process when

you perform a re-canalization, and to treat by endovascular therapy, SFA, and popliteal lesion, and I think we can perform a first dilation with POVAR with a balloon superior of 1 mm, compared to the diameter of the SFA.

And it's very important to perform an inflation during three minutes and to follow with a slow deflation and a gentle removal. And stent to the diameter of the SFA, and maybe it's important to use, in certain cases of the DEB.

So the success keys: Is a good experience of re-canalization, a good knowledge of the devices, and a preparation of the vessel. For me, it's very important and the quality of the angiogram tube,

so I would like to share you some example. Here is the example, and a thrombosis occlusion of the whole SFA, and for me you can see on the angiogram the results and it's very important to have a disparation of the decrease of the collateral injection

on the angiogram. This is a case with a total occlusion of SFA in the stent And you can see on the angiogram thrombosis of the stent at the anterior, and I performed for this patient retrograde puncture inside the stent,

and I take the guide wire with the retrograde puncture with the snare and I treat the artery. So, to avoid an hematoma at the puncture it's necessary to inflate before the balloon inside the stent

after the re-canalization, and to remove the introducer and to let the inflation during five minutes. And so, another cases with the total occlusion of the SFA and a very good result, and a very difficult case with a lot of calcification, and it's possible to perform SFA endovascular repair with these techniques.

Okay, and a case, total occlusion SFA, popliteal artery, and the leg artery, and we perform a re-canalization and we use a third-generation stent, Supera, and to have a very good result. And in terms of results, what do the studies say? Analysis of endovascular therapy for femoropopliteal disease

with the Supera stent in Journal of Vascular Surgery shows primary patency is very good, at 90% at one year. Another study, the study with my colleagues, we've used a third-generation of stent with a very good result at 24 months. And open surgery and the estimated

five-year primary patency was 64%. Okay, and in conclusion: For me, "There is no impregna "There are only badly attacked citadels." Thank you very much for your attention.

- These are my disclosure, did not influence my work. I would like to thank you for Dr. Weith for the invitation. And I think this is time we cannot ignore anymore one of our major complication during the procedures not just TAVIing with any other surgeries. My tool is the transcranial doppler and I just call it the

stethoscope to the brain because it's really listen to the flow, measure the speed of the flow, measure the direction of the flow. But it also tells me by the resistance if the vessel in the brain occluded or open.

So this is the example how an embolus traveling in the middle cerebral artery or the ACA look like. And again there's not many of those good emboli. The only good emboli we using for PFO testing. But-- sorry--

My pointer would like to show you that on the right bottom corner this is how an MC occlusion looks like real time when a waveform just disappears. This is the example also a teaching tool that you can was the contrast injection and how the lots of air with the contrast injection look like.

But again going back to the TAVI, you can see that the cerebral DWI lesion 90, 80 almost 86 percent, it's a really high number for this procedure. And when you divide them by the transcranial doppler you can see the balloon valvuloplasty and the placement

of the valve comes with the highest emboli count. During their study in Houston this is how they divided the procedure to different phases. And I just want to walk you through a procedure. And this is one of the first challenge, just crossing the valve.

Look at those white lines on the TCD real time while your wire trying to cross your valve. Those are all microemboli. During the BAV you can see there's a hypoperfusion. So hypoperfusion the brain really doesn't like hypoperfusion too much.

So but when you see the folly sword you can see the microemboli too. So again not just the microembolization but the hemodynamics, how your hypoperfusion is really important. And a successful BAV and a valve placement shows that you

have end diastolic flow. Here comes the arch crossing by the TAVI. And you can see just crossing the arch it's also comes with embolization. And why your positioning? The positioning itself again comes

with a shower of microembolization. And it also see that the diastolic profusion is also suffers. And a low diastolic profusion is hyperprofusion again. And why the placement you see the rapid pacing, this is comes with again hyperprofusion and microemboli.

Those are the incidents how we can see by deflating the balloon you're going to see the incidents of microembolization. The different valves again results of no flow pattern. And this is again, in this moment you can see the flow is gone.

Your concern is this something that we just lost a signal. The flow comes back and these are lack of signals and lack of flow of temporarily. But we can also assess how the AI is treated when there's no diastolic flow. That's not good,

that's correlating nicely. And the final results when finally you have a good end diastolic flow pattern that tells you that your surgery's successful. Again different devices can be studied by the DCD, a low deployment versus the balloon deployment.

And this is my most scary picture when you see that the valve is crossing the arch and one of the signals you're going to see and disappear. So this is why we encourage bilateral signal, bilateral MCM monitoring. And here when the microemboli comes,

your signal disappearing, that resulting in a stroke. And you can again act and go to the neuro angio suite. So our data also showed that despite that we have a really low number of stroke and TIA's, we didn't see too much difference.

But phase five, this is when the deployment happens with the high emboli count. But also you cannot ignore that the phase two, when you just moving your catheter causing the valve come through the high emboli count as well.

And just a different way of showing you that majority of the HITS again comes with the valve deployment. But also the low flow stages when we have hyperprofusion we just cannot ignore. Thank you so much for your attention.

- Good morning. I'd like to thank Dr. Veith and Symposium for my opportunity to speak. I have no disclosures. So the in Endovascular Surgery, there is decrease open surgical bypass. But, bypass is still required for many patients with PAD.

Autologous vein is preferred for increase patency lower infection rate. And, Traditional Open Vein Harvest does require lengthy incisions. In 1996 cardiac surgery reported Endoscopic Vein Harvest. So the early prospective randomized trial

in the cardiac literature, did report wound complications from Open Vein Harvest to be as high as 19-20%, and decreased down to 4% with Endoscopic Vein Harvest. Lopes et al, initially, reported increase risk of 12-18 month graft failure and increased three year mortality.

But, there were many small studies that show no effect on patency and decreased wound complications. So, in 2005, Endoscopic Vein Harvest was recommended as standard of care in cardiac surgical patients. So what about our field? The advantages of Open Vein Harvest,

we all know how to do it. There's no learning curve. It's performed under direct visualization. Side branches are ligated with suture and divided sharply. Long term patency of the bypass is established. Disadvantages of the Open Vein Harvest,

large wound or many skip wounds has an increased morbidity. PAD patients have an increased risk for wound complications compared to the cardiac patients as high as 22-44%. The poor healing can be due to ischemia, diabetes, renal failure, and other comorbid conditions.

These can include hematoma, dehiscense, infection, and increased length of stay. So the advantages of Endoscopic Vein Harvest, is that there's no long incisions, they can be performed via one or two small incisions. Limiting the size of an incision

decreases wound complications. It's the standard of care in cardiac surgery, and there's an overall lower morbidity. The disadvantages of is that there's a learning curve. Electro-cautery is used to divide the branches, you need longer vein compared to cardiac surgery.

There's concern about inferior primary patency, and there are variable wound complications reported. So recent PAD data, there, in 2014, a review of the Society of Vascular Surgery registry, of 5000 patients, showed that continuous Open Vein Harvest

was performed 49% of the time and a Endo Vein Harvest about 13% of the time. The primary patency was 70%, for Continuous versus just under 59% for Endoscopic, and that was significant. Endoscopic Vein Harvest was found to be an independent risk factor for a lower one year

primary patency, in the study. And, the length of stay due to wounds was not significantly different. So, systematic review of Endoscopic Vein Harvest data in the lower extremity bypass from '96 to 2013 did show that this technique may reduce

primary patency with no change in wound complications. Reasons for decreased primary patency, inexperienced operator, increased electrocautery injury to the vein. Increase in vein manipulation, you can't do the no touch technique,

like you could do with an Open Harvest. You need a longer conduit. So, I do believe there's a roll for this, in the vascular surgeon's armamentarium. I would recommend, how I use it in my practices is, I'm fairly inexperienced with Endoscopic Vein Harvest,

so I do work with the cardiac PA's. With increased percutaneous procedures, my practice has seen decreased Saphenous Vein Bypasses, so, I've less volume to master the technique. If the PA is not available, or the conduit is small, I recommend an Open Vein Harvest.

The PA can decrease the labor required during these cases. So, it's sometimes nice to have help with these long cases. Close surveillance follow up with Non-Invasive Arterial Imaging is mandatory every three months for the first year at least. Thank you.

- Thank you very much for the kind introduction, and I'd like to thank the organizers, especially Frank Veith for getting back to this outstanding and very important conference. My duty is now to talk about the acute status of carotid artery stenting is acute occlusion an issue? Here are my disclosures.

Probably you might be aware, for sure you're aware about pore size and probably smaller pore size, the small material load might be a predisposing factor for enhanced thrombogenicity in these dual layer stents, as you're probably quite familiar with the CGUARD, Roadsaver and GORE, I will focus my talk a little bit

on the Roadsaver stent, since I have the most experience with the Roadsaver stent from the early beginning when this device was on the market in Europe. If you go back a little bit and look at the early publications of CGUARD, Roadsaver and GORE stent, then acute occlusion the early reports show that

very clearly safety, especially at 30 days in terms of major cardiac and cerebrovascular events. They are very, very safe, 0% in all these early publications deal with these stents. But you're probably aware of this publication, released end of last year, where a German group in Hamburg

deals with carotid artery stenosis during acute stroke treatment. They used the dual layer stent, the Roadsaver stent or the Casper stent in 20 cases, in the same time period from 2011 to 2016, they used also the Wallstent and the VIVEXX stent,

in 27 cases in total and there was a major difference, in terms of acute stent occlusion, and for the Roadsaver or Casper stent, it was 45%, they also had an explanation for that, potential explanations probably due to the increase of thrombogenic material due to the dual layer

insufficient preparation with antiplatelet medication, higher patient counts in the patients who occluded, smaller stent diameters, and the patients were not administered PTA, meaning Bridging during acute stroke patient treatment, but it was highlighted that all patients received ASA of 500mg intravenously

during the procedure. But there are some questions coming up. What is a small stent diameter? Post-dilatation at what diameter, once the stent was implanted? What about wall apposition of the stent?

Correct stent deployment with the Vicis maneuver performed or not and was the ACT adjusted during the procedure, meaning did they perform an adequate heparinization? These are open questions and I would like to share our experience from Flensburg,

so we have treated nearly 200 patients with the Roadsaver stent from 2015 until now. In 42 patients, we used this stent exclusively for acute stroke treatment and never, ever observed in both groups, in the symptomatic and asymptomatic group and in the group of acute stroke treatment,

we never observed an acute occlusion. How can we explain this kind of difference that neither acute occlusion occurred in our patient group? Probably there are some options how we can avoid stent thrombosis, how we can minimize this. For emergency treatment, probably this might be related

to bridging therapies, though in Germany a lot of patients who received acute stroke treatment are on bridging therapy since the way to the hospital is sometimes rather long, there probably might be a predisposing factor to re-avoid stent thrombosis and so-called tandem lesions if the stent placement is needed.

But we also take care of antiplatelet medication peri-procedurally, and we do this with ASA, as the Hamburg group did and at one day, we always start, in all emergency patients with clopidogrel loading dose after positive CT where we could exclude any bleeding and post-procedurally we go

for dual anti-platelet therapy for at least six months, meaning clopidogrel and ASA, and this is something probably of utmost importance. It's quite the same for elective patients, I think you're quite familiar with this, and I want to highlight the post-procedural clopidogrel

might be the key of success for six months combined with ASA life-long. Stent preparation is also an issue, at least 7 or 8 diameters we have to choose for the correct lengths we have to perform adequate stent deployment and adequate post-dilatation

for at least 5mm. In a lot of trials the Roadsaver concept has been proven, and this is due to the adequate preparation of the stent and ongoing platelet preparation, and this was also highlight in the meta-analysis with the death and stroke rate of .02% in all cases.

Roadsaver study is performed now planned, I am a member of the steering committee. In 2000 patients, so far 132 patients have been included and I want to rise up once again the question, is acute occlusion and issue? No, I don't think so, since you keep antiplatelet medication

in mind and be aware of adequate stent sizing. I highly appreciated your attention, thank you very much.

- Thank you (mumbles) and thank you Dr. Veith for the kind invitation to participate in this amazing meeting. This is work from Hamburg mainly and we all know that TEVAR is the first endovascular treatment of choice but a third of our patients will fail to remodel and that's due to the consistent and persistent

flow in the false lumen over the re-entrance in the thoracoabdominal aorta. Therefore it makes sense to try to divide the compartments of the aorta and try to occlude flow in the false lumen and this can be tried by several means as coils, plug and glue

but also iliac occluders but they all have the disadvantage that they don't get over 24 mm which is usually not enough to occlude the false lumen. Therefore my colleague, Tilo Kolbel came up with this first idea with using

a pre-bulged stent graft at the midportion which after ballooning disrupts the dissection membrane and opposes the outer wall and therefore occludes backflow into the aneurysm sac in the thoracic segment, but the most convenient

and easy to use tool is the candy-plug which is a double tapered endograft with a midsegment that is 18 mm and once implanted in the false lumen at the level of the supraceliac aorta it occludes the backflow in the false lumen in the thoracic aorta

and we have seen very good remodeling with this approach. You see here a patient who completely regressed over three years and it also answers the question how it behaves with respect to true and false lumen. The true lumen always wins and because once

the false lumen thrombosis and the true lumen also has the arterial pressure it does prevail. These are the results from Hamburg with an experience of 33 patients and also the international experience with the CMD device that has been implanted in more than 20 cases worldwide

and we can see that the interprocedural technical success is extremely high, 100% with no irrelevant complications and also a complete false lumen that is very high, up to 95%. This is the evolvement of the candy-plug

over the years. It started as a surgeon modified graft just making a tie around one of the stents evolving to a CMD and then the last generation candy-plug II that came up 2017 and the difference, or the new aspect

of the candy-plug II is that it has a sleeve inside and therefore you can retrieve the dilator without having to put another central occluder or a plug in the central portion. Therefore when the dilator is outside of the sleeve the backflow occludes the sleeve

and you don't have to do anything else, but you have to be careful not to dislodge the whole stent graft while retrieving the dilator. This is a case of a patient with post (mumbles) dissection.

This is the technique of how we do it, access to the false lumen and deployment of the stent graft in the false lumen next to the true lumen stent graft being conscious of the fact that you don't go below the edge of the true lumen endograft

to avoid (mumbles) and the final angiography showing no backflow in the aneurysm. This is how we measure and it's quite simple. You just need about a centimeter in the supraceliac aorta where it's not massively dilated and then you just do an over-sizing

in the false lumen according to the Croissant technique as Ste-phan He-lo-sa has described by 10 to 30% and what is very important is that in these cases you don't burn any bridges. You can still have a good treatment

of the thoracic component and come back and do the fenestrated branch repair for the thoracoabdominal aorta if you have to. Thank you very much for your attention. (applause)

- Thanks Fieres. Thank you very much for attending this session and Frank for the invitation. These are my disclosures. We have recently presented the outcomes of the first 250 patients included in this prospective IDE at the AATS meeting in this hotel a few months ago.

In this study, there was no in-hospital mortality, there was one 30-day death. This was a death from a patient that had intracranial hemorrhage from the spinal drain placement that eventually was dismissed to palliative care

and died on postoperative day 22. You also note that there are three patients with paraplegia in this study, one of which actually had a epidural hematoma that was led to various significant and flacid paralysis. That prompted us to review the literature

and alter our outcomes with spinal drainage. This review, which includes over 4700 patients shows that the average rate of complications is 10%, some of those are relatively moderate or minor, but you can see a rate of intracranial hemorrhage of 1.5% and spinal hematoma of 1% in this large review,

which is essentially a retrospective review. We have then audited our IDE patients, 293 consecutive patients treated since 2013. We looked at all their spinal drains, so there were 240 placement of drains in 187 patients. You can see that some of these were first stage procedures

and then the majority of them were the index fenestrated branch procedure and some, a minority were Temporary Aneurysm Sac Perfusions. Our rate of complication was identical to the review, 10% and I want to point out some of the more important complications.

You can see here that intracranial hypotension occurred in 6% of the patients, that included three patients, or 2%, with intracranial hemorrhage and nine patients, or 5%, with severe headache that prolonged hospital stay and required blood patch for management.

There were also six patients with spinal hematomas for a overall rate of 3%, including the patient that I'll further discuss later. And one death, which was attributed to the spinal drain. When we looked at the intracranial hypotension in these 12 patients, you can see

the median duration of headache was four days, it required narcotics in seven patients, blood patch in five patients. All these patients had prolonged hospital stay, in one case, the prolongation of hospital stay was of 10 days.

Intracranial hemorrhage in three patients, including the patient that I already discussed. This patient had a severe intracranial hemorrhage which led to a deep coma. The patient was basically elected by the family to be managed with palliative care.

This patient end up expiring on postoperative day 21. There were other two patients with intracranial hemorrhage, one remote, I don't think that that was necessarily related to the spinal drain, nonetheless we had it on this review. These are some of the CT heads of the patients that had intracranial hemorrhage,

including the patient that passed away, which is outlined in the far left of your slide. Six patients had spinal hematoma, one of these patients was a patient, a young patient treated for chronic dissection. Patient evolved exceptionally well, moving the legs,

drain was removed on postoperative day two. As the patient is standed out of the bed, felt weakness in the legs, we then imaged the spine. You can see here, very severe spinal hematoma. Neurosurgery was consulted, decided to evacuate, the patient woke up with flacid paralysis

which has not recovered. There were two other patients with, another patient with paraplegia which was treated conservatively and improved to paraparesis and continues to improve and two other patients with paraparesis.

That prompted changes in our protocol. We eliminated spinal drains for Extent IVs, we eliminated for chronic dissection, in first stages, on any first stage, and most of the Extent IIIs, we also changed our protocol of drainage

from the routine drainage of a 10 centimeters of water for 15 minutes of the hours to a maximum of 20 mL to a drainage that's now guided by Near Infrared Spectroscopy, changes or symptoms. This is our protocol and I'll illustrate how we used this in one patient.

This is a patient that actually had this actual, exact anatomy. You can see the arch was very difficult, the celiac axis was patent and provided collateral flow an occluded SMA. The right renal artery was chronically occluded.

As we were doing this case the patient experienced severe changes in MEP despite the fact we had flow to the legs, we immediately stopped the procedure with still flow to the aneurysm sac. The patient develops pancreatitis, requires dialysis

and recovers after a few days in the ICU with no neurological change. Then I completed the repair doing a subcostal incision elongating the celiac axis and retrograde axis to this graft to complete the branch was very difficult to from the arm

and the patient recovered with no injury. So, in conclusion, spinal drainage is potentially dangerous even lethal and should be carefully weighted against the potential benefits. I think that our protocol now uses routine drainage for Extent I and IIs,

although I still think there is room for a prospective randomized trial even on this group and selective drainage for Extent IIIs and no drainage for Extent IVs. We use NIRS liberally to guide drainage and we use temporary sac perfusion

in those that have changes in neuromonitoring. Thank you very much.

- Thanks Bill and I thank Dr. Veith and the organizers of the session for the invitation to speak on histology of in-stent stenosis. These are my disclosures. Question, why bother with biopsy? It's kind of a hassle. What I want to do is present at first

before I show some of our classification of this in data, is start with this case where the biopsy becomes relevant in managing the patient. This is a 41 year old woman who was referred to us after symptom recurrence two months following left iliac vein stenting for post-thrombotic syndrome.

We performed a venogram and you can see this overlapping nitinol stents extending from the..., close to the Iliocaval Confluence down into Common Femoral and perhaps Deep Femoral vein. You can see on the venogram, that it is large displacement of the contrast column

from the edge of the stent on both sides. So we would call this sort of diffuse severe in-stent stenosis. We biopsy this material, you can see it's quite cellular. And in the classification, Doctor Gordon, our pathologist, applies to all these.

Consisted of fresh thrombus, about 15% of the sample, organizing thrombus about zero percent, old thrombus, which is basically a cellular fibrin, zero percent and diffuse intimal thickening - 85%. And you can see there is some evidence of a vascularisation here, as well as some hemosiderin deposit,

which, sort of, implies a red blood cell thrombus, histology or ancestry of this tissue. So, because the biopsy was grossly and histolo..., primarily grossly, we didn't have the histology to time, we judged that thrombolysis had little to offer this patient The stents were angioplastied

and re-lined with Wallstents this time. So, this is the AP view, showing two layers of stents. You can see the original nitinol stent on the outside, and a Wallstent extending from here. Followed venogram, venogram at the end of the procedure, shows that this displacement, and this is the maximal

amount we could inflate the Wallstent, following placement through this in-stent stenosis. And this is, you know, would be nice to have a biological or drug solution for this kind of in-stent stenosis. We brought her back about four months later, usually I bring them back at six months,

but because of the in-stent stenosis and suspecting something going on, we brought her back four months later, and here you can see that the gap between the nitinol stent and the outside the wall stent here. Now, in the contrast column, you can see that again, the contrast column is displaced

from the edge of the Wallstent, so we have recurrent in-stent stenosis here. The gross appearance of this clot was red, red-black, which suggests recent thrombus despite anticoagulation and the platelet. And, sure enough, the biopsy of fresh thrombus was 20%,

organizing thrombus-75%. Again, the old thrombus, zero percent, and, this time, diffuse intimal thickening of five percent. This closeup of some of that showing the cells, sort of invading this thrombus and starting organization. So, medical compliance and outflow in this patient into IVC

seemed acceptable, so we proceeded to doing ascending venogram to see what the outflow is like and to see, if she was an atomic candidate for recanalization. You can see these post-thrombotic changes in the popliteal vein, occlusion of the femoral vein.

You can see great stuffiness approaching these overlapping stents, but then you can see that the superficial system has been sequestered from the deep system, and now the superficial system is draining across midline. So, we planned to bring her back for recanalization.

So biopsy one with diffuse intimal thickening was used to forego thrombolysis and proceed with PTA and lining. Biopsy two was used to justify the ascending venogram. We find biopsy as a useful tool, making practical decisions. And Doctor Gordon at our place has been classifying these

biopsies in therms of: Fresh Thrombus, Organizing Thrombus, Old Thrombus and Diffuse Intimal thickening. These are panels on the side showing the samples of each of these classifications and timelines. Here is a timeline of ...

Organizing Thrombus here. To see it's pretty uniform series of followup period For Diffuse Intimal thickening, beginning shortly after the procedure, You won't see very much at all, increases with time. So, Fresh Thrombus appears to be

most prevalent in early days. Organizing Thrombus can be seen at early time points sample, as well as throughout the in-stent stenosis. Old Thrombus, which is a sort of a mystery to me why one pathway would be Old Thrombus and the other Diffuse Intimal thickening.

We have to work that out, I hope. Calcification is generally a very late feature in this process. Thank you very much.

- So I'd like to thank Dr. Ascher, Dr. Sidawy, Dr. Veith, and the organizers for allowing us to present some data. We have no disclosures. The cephalic arch is defined as two centimeters from the confluence of the cephalic vein to either the auxiliary/subclavian vein. Stenosis in this area occurs about 39%

in brachiocephalic fistulas and about 2% in radiocephalic fistulas. Several pre-existing diseases can lead to the stenosis. High flows have been documented to lead to the stenosis. Acute angles. And also there is a valve within the area.

They're generally short, focal in nature, and they're associated with a high rate of thrombosis after intervention. They have been associated with turbulent flow. Associated with pre-existing thickening.

If you do anatomic analysis, about 20% of all the cephalic veins will have that. This tight anatomical angle linked to the muscle that surrounds it associated with this one particular peculiar valve, about three millimeters from the confluence.

And it's interesting, it's common in non-diabetics. Predictors if you are looking for it, other than ultrasound which may not find it, is calcium-phosphate product, platelet count that's high, and access flow.

If one looks at interventions that have commonly been reported, one will find that both angioplasty and stenting of this area has a relatively low primary patency with no really discrimination between using just the balloon or stent.

The cumulative patency is higher, but really again, deployment of an angioplasty balloon or deployment of a stent makes really no significant difference. This has been associated with residual stenosis

greater than 30% as one reason it fails, and also the presence of diabetes. And so there is this sort of conundrum where it's present in more non-diabetics, but yet diabetics have more of a problem. This has led to people looking to other alternatives,

including stent grafts. And in this particular paper, they did not look at primary stent grafting for a cephalic arch stenosis, but mainly treating the recurrent stenosis. And you can see clearly that the top line in the graph,

the stent graft has a superior outcome. And this is from their paper, showing as all good paper figures should show, a perfect outcome for the intervention. Another paper looked at a randomized trial in this area and also found that stent grafts,

at least in the short period of time, just given the numbers at risk in this study, which was out after months, also had a significant change in the patency. And in their own words, they changed their practice and now stent graft

rather than use either angioplasty or bare-metal stents. I will tell you that cutting balloons have been used. And I will tell you that drug-eluting balloons have been used. The data is too small and inconclusive to make a difference. We chose a different view.

We asked a simple question. Whether or not these stenoses could be best treated with angioplasty, bare-metal stenting, or two other adjuncts that are certainly related, which is either a transposition or a bypass.

And what we found is that the surgical results definitely give greater long-term patency and greater functional results. And you can see that whether you choose either a transposition or a bypass, you will get superior primary results.

And you will also get superior secondary results. And this is gladly also associated with less recurrent interventions in the ongoing period. So in conclusion, cephalic arch remains a significant cause of brachiocephalic AV malfunction.

Angioplasty, across the literature, has poor outcomes. Stent grafting offers the best outcomes rather than bare-metal stenting. We have insufficient data with other modalities, drug-eluting stents, drug-eluting balloons,

cutting balloons. In the correct patient, surgical options will offer superior long-term results and functional results. And thus, in the good, well-selected patient, surgical interventions should be considered

earlier in this treatment rather than moving ahead with angioplasty stent and then stent graft. Thank you so much.

- Thank you Mr. Chairman, good morning ladies and gentlemen. So that was a great setting of the stage for understanding that we need to prevent reinterventions of course. So we looked at the data from the DREAM trial. We're all aware that we can try

to predict secondary interventions using preoperative CT parameters of EVAR patients. This is from the EVAR one trial, from Thomas Wyss. We can look at the aortic neck, greater angulation and more calcification.

And the common iliac artery, thrombus or tortuosity, are all features that are associated with the likelihood of reinterventions. We also know that we can use postoperative CT scans to predict reinterventions. But, as a matter of fact, of course,

secondary sac growth is a reason for reintervention, so that is really too late to predict it. There are a lot of reinterventions. This is from our long term analysis from DREAM, and as you can see the freedom, survival freedom of reinterventions in the endovascular repair group

is around 62% at 12 years. So one in three patients do get confronted with some sort of reintervention. Now what can be predicted? We thought that the proximal neck reinterventions would possibly be predicted

by type 1a Endoleaks and migration and iliac thrombosis by configurational changes, stenosis and kinks. So the hypothesis was: The increase of the neck diameter predicts proximal type 1 Endoleak and migration, not farfetched.

And aneurysm shrinkage maybe predicts iliac limb occlusion. Now in the DREAM trial, we had a pretty solid follow-up and all patients had CT scans for the first 24 months, so the idea was really to use

those case record forms to try to predict the longer term reinterventions after four, five, six years. These are all the measurements that we had. For this little study, and it is preliminary analysis now,

but I will be presenting the maximal neck diameter at the proximal anastomosis. The aneurysm diameter, the sac diameter, and the length of the remaining sac after EVAR. Baseline characteristics. And these are the re-interventions.

For any indications, we had 143 secondary interventions. 99 of those were following EVAR in 54 patients. By further breaking it down, we found 18 reinterventions for proximal neck complications, and 19 reinterventions

for thrombo-occlusive limb complications. So those are the complications we are trying to predict. So when you put everything in a graph, like the graphs from the EVAR 1 trial, you get these curves,

and this is the neck diameter in patients without neck reintervention, zero, one month, six months, 12, 18, and 24 months. There's a general increase of the diameter that we know.

But notice it, there are a lot of patients that have an increase here, and never had any reintervention. We had a couple of reinterventions in the long run, and all of these spaces seem to be staying relatively stable,

so that's not helping much. This is the same information for the aortic length reinterventions. So statistical analysis of these amounts of data and longitudinal measures is not that easy. So here we are looking at

the neck diameters compared for all patients with 12 month full follow-up, 18 and 24. You see there's really nothing happening. The only thing is that we found the sac diameter after EVAR seems to be decreasing more for patients who have had reinterventions

at their iliac limbs for thrombo-occlusive disease. That is something we recognize from the literature, and especially from these stent grafts in the early 2000s. So conclusion, Mr. Chairman, ladies and gentlemen, CT changes in the first two months after EVAR

predict not a lot. Neck diameter was not predictive for neck-reinterventions. Sac diameter seems to be associated with iliac limb reinterventions, and aneurysm length was not predictive

of iliac limb reinterventions. Thank you very much.

- Thank you, good morning everybody. Thank you for the kind invitation, Professor Veith, it's an honor for me to be here again this year in New York. I will concentrate my talk about the technical issues and the experience in the data we have already published about the MISACE in more than 50 patients.

So I have no disclosure regarded to this topic. As you already heard, the MISACE means the occlusion of the main stem of several segmental arteries to preserve the capability of the collateral network to build new arteries. And as a result, we developed

the ischemic preconditioning of the spinal cord. Why is this so useful? Because it's an entirely endovascular first stage of a staged approach to treat thoracoabdominal aortic aneurysm in order to reduce the ischemic spinal cord injury.

How do you perform the MISACE? Basically, we perform the procedure in local anesthesia, through a percutaneous trans-femoral access using a small-bore sheath. The patient is awake, that means has no cerebrospinal fluid damage

so we can monitor the patient's neurological for at least 48 hours after the procedure. So, after the puncture of the common femoral artery, using a technique of "tower of power" in order to cannulate the segmental arteries. As you can see here, we started with a guiding catheter,

then we place a diagnosis catheter and inside, a microcatheter that is placed inside the segmental artery. Then we started occlusion of the ostial segment of the segmental artery. We use coils or vascular plugs.

We don't recommend the use of fluids due to the possible distal embolization and the consequences. Since we have started this procedure, we have gained a lot of experience and we have started to ask,

what is a sufficient coilembolization? As you can see here, this artery, we can see densely packed coils inside, but you can see still blood flowing after the coil. So, was it always occluding, or is it spontaneous revascularization?

That, we do not know yet. The question, is it flow reduction enough to have a ischemic precondition of the spinal cord? Another example here, you can see a densely packed coil in the segmental artery at the thoracic level. There are some other published data

with some coils in the segm the question is, which technique should we use, the first one, the second one? Another question, is which kind of coil to use? For the moment, we can only use the standard coils

in our center, but I think if we have 3-D or volume coils or if you have microvascular plugs that are very compatible with the microcatheter, we have a superior packing density, we can achieve a better occlusion of the segmental artery, and we have less procedure time and radiation time,

but we have to think of the cost. We recommend to start embolization of the segmental artery, of course, at the origin of it, and not too far inside. Here, you can see a patient where we have coiled a segmental artery very shortly after the ostium,

but you can see here also the development of the collaterals just shortly before the coils, leading to the perfusion of segmental artery that was above it. As you can see, we still have a lot of open question. Is it every patent segmental artery

a necessary to coil? Should we coil only the large ones? I show you an example here, you can see this segmental artery with a high-grade stenotic twisted ostium due to aortic enlargement.

I can show you this segmental artery, six weeks after coiling of a segmental artery lower, and you can see that the ostium, it's no more stenotic and you can see also the connection between the segmental artery below to the initial segmental artery.

Another question that we have, at which level should we start the MISACE? Here, can see a patient with a post-dissection aneurysm after pedicle technique, so these are all uncovered dissection stent, and you can see very nicely the anterior spinal artery

feeded by the anterior radiculomedullary artery from the segmental artery. So, in this patient, in fact, we start the coiling exactly at the seat of this level, we start to coil the segmental artery that feeds the anterior spinal artery.

So, normally we find this artery of the Th 9 L1, and you can see here we go upwards and downwards. We have some challenges with aneurysm sac enlargement, in this case, we use this technique to open the angle of the catheter, we can use also deflectable steerable sheath

in order to reach the segmental artery. And you can see here our results, again, I just will go fast through those, we have treated 57 patients, most of them were Type II, Type III aortic aneurysms. We have found in median nine patent segmental artery

at the level of the aorta to be treated, between 2 and 26, and we have coiled in multiple sessions with a mean interval of 60 days between the sessions. No sooner than seven days we perform the complete exclusion of the aneurysm

in order to let the collateral to develop, and you can see our result: at 30 days we had no spinal cord ischemia. So I can conclude that our first experience suggest that MISACE is feasible, safe, and effective, but segmental artery coiling in thoracoabdominal aneurysm

can be challenging, it's a new field with many open questions, and I looking forward for the results with PAPA_ARTiS study. Thank you a lot.

- Thank you. I have a little disclosure. I've got to give some, or rather, quickly point out the technique. First apply the stet graph as close as possible to the hypogastric artery.

As you can see here, the end of distal graft. Next step, come from the left brachial you can lay the catheter in the hypogastric artery. And then come from both

as you can see here, with this verge catheter and you put in position the culver stent, and from the femoral you just put in position the iliac limb orthostatic graft.

The next step, apply the stent graft, the iliac limb stent graft, keep the viabahn and deployed it in more the part here. What you have here is five centimeter overlap to avoid Type I endoleak.

The next step, use a latex balloon, track over to the iliac limb, and keep until the, as you can see here, the viabahn is still undeployed. In the end of the procedure,

at least one and a half centimeters on both the iliac lumen to avoid occlusion to viabahn. So we're going to talk about our ten years since I first did my first description of this technique. We do have the inclusion criteria

that's very important to see that I can't use the Sandwich Technique with iliac lumen unless they are bigger than eight millimeters. That's one advantage of this technique. I can't use also in the very small length

of common iliac artery and external iliac artery and I need at least four millimeters of the hypogastric artery. The majority patients are 73 age years old. Majority males. Hypertension, a lot of comorbidity of oldest patients.

But the more important, here you can see, when you compare the groups with the high iliac artery and aneurismal diameter and treat with the Sandwich Technique, you can see here actually it's statistically significant

that I can treat patient with a very small real lumen regarding they has in total diameter bigger size but I can treat with very small lumen. That's one of the advantages of this technique. You can see the right side and also in the left side. So all situations, I can treat very small lumen

of the aneurysm. The next step so you can show here is about we performed this on 151 patients. Forty of these patients was bilateral. That's my approach of that. And you can see, the procedure time,

the fluoroscope time is higher in the group that I performed bilaterally. And the contrast volume tends to be more in the bilateral group. But ICU stay, length of stay, and follow up is no different between these two groups.

The technical success are 96.7%. Early mortality only in three patients, one patient. Late mortality in 8.51 patients. Only one was related with AMI. Reintervention rate is 5, almost 5.7 percent. Buttock claudication rate is very, very rare.

You cannot find this when you do Sandwich Technique bilaterally. And about the endoleaks, I have almost 18.5% of endoleaks. The majority of them was Type II endoleaks. I have some Type late endoleaks

also the majority of them was Type II endoleaks. And about the other complications I will just remark that I do not have any neurological complications because I came from the left brachial. And as well I do not have colon ischemia

and spinal cord ischemia rate. And all about the evolution of the aneurysm sac. You'll see the majority, almost two-thirds have degrees of the aneurysm sac diameter. And some of these patients

we get some degrees but basically still have some Type II endoleak. That's another very interesting point of view. So you can see here, pre and post, decrease of the aneurysm sac.

You see the common iliac artery pre and post decreasing and the hypogastric also decreasing. So in conclusion, the Sandwich Technique facilitates safe and effective aneurysm exclusion

and target vessel revascularization in adverse anatomical scenarios with sustained durability in midterm follow-up. Thank you very much for attention.

- Thank you. I have two talks because Dr. Gaverde, I understand, is not well, so we- - [Man] Thank you very much. - We just merged the two talks. All right, it's a little joke. For today's talk we used fusion technology

to merge two talks on fusion technology. Hopefully the rest of the talk will be a little better than that. (laughs) I think we all know from doing endovascular aortic interventions

that you can be fooled by the 2D image and here's a real life view of how that can be an issue. I don't think I need to convince anyone in this room that 3D fusion imaging is essential for complex aortic work. Studies have clearly shown it decreases radiation,

it decreases fluoro time, and decreases contrast use, and I'll just point out that these data are derived from the standard mechanical based systems. And I'll be talking about a cloud-based system that's an alternative that has some advantages. So these traditional mechanical based 3D fusion images,

as I mentioned, do have some limitations. First of all, most of them require manual registration which can be cumbersome and time consuming. Think one big issue is the hardware based tracking system that they use. So they track the table rather than the patient

and certainly, as the table moves, and you move against the table, the patient is going to move relative to the table, and those images become unreliable. And then finally, the holy grail of all 3D fusion imaging is the distortion of pre-operative anatomy

by the wires and hardware that are introduced during the course of your procedure. And one thing I'd like to discuss is the possibility that deep machine learning might lead to a solution to these issues. How does 3D fusion, image-based 3D fusion work?

Well, you start, of course with your pre-operative CT dataset and then you create digitally reconstructed radiographs, which are derived from the pre-op CTA and these are images that resemble the fluoro image. And then tracking is done based on the identification

of two or more vertebral bodies and an automated algorithm matches the most appropriate DRR to the live fluoro image. Sounds like a lot of gobbledygook but let me explain how that works. So here is the AI machine learning,

matching what it recognizes as the vertebral bodies from the pre-operative CT scan to the fluoro image. And again, you get the CT plus the fluoro and then you can see the overlay with the green. And here's another version of that or view of that.

You can see the AI machine learning, identifying the vertebral bodies and then on your right you can see the fusion image. So just, once again, the AI recognizes the bony anatomy and it's going to register the CT with the fluoro image. It tracks the patient, not the table.

And the other thing that's really important is that it recognizes the postural change that the patient undergoes between the posture during the CT scan, versus the posture on the OR table usually, or often, under general anesthesia. And here is an image of the final overlay.

And you can see the visceral and renal arteries with orange circles to identify them. You can remove those, you can remove any of those if you like. This is the workflow. First thing you do is to upload the CT scan to the cloud.

Then, when you're ready to perform the procedure, that is downloaded onto the medical grade PC that's in your OR next to your fluoro screen, and as soon as you just step on the fluoro pedal, the CYDAR overlay appears next to your, or on top of your fluoro image,

next to your regular live fluoro image. And every time you move the table, the computer learning recognizes that the images change, and in a couple of seconds, it replaces with a new overlay based on the obliquity or table position that you have. There are some additional advantages

to cloud-based technology over mechanical technology. First of all, of course, or hardware type technology. Excuse me. You can upgrade it in real time as opposed to needing intermittent hardware upgrades. Works with any fluoro equipment, including a C-arm,

so you don't have to match your 3D imaging to the brand of your fluoro imaging. And there's enhanced accuracy compared to mechanical registration systems as imaging. So what are the clinical applications that this can be utilized for?

Fluoroscopy guided endovascular procedures in the lower thorax, abdomen, and pelvis, so that includes EVAR and FEVAR, mid distal TEVAR. At present, we do need two vertebral bodies and that does limit the use in TEVAR. And then angioplasty stenting and embolization

of common iliac, proximal external and proximal internal iliac artery. Anything where you can acquire a vertebral body image. So here, just a couple of examples of some additional non EVAR/FEVAR/TEVAR applications. This is, these are some cases

of internal iliac embolization, aortoiliac occlusion crossing, standard EVAR, complex EVAR. And I think then, that the final thing that I'd like to talk about is the use with C-arm, which is think is really, extremely important.

Has the potential to make a very big difference. All of us in our larger OR suites, know that we are short on hybrid availability, and yet it's difficult to get our institutions to build us another hybrid room. But if you could use a high quality 3D fusion imaging

with a high quality C-arm, you really expand your endovascular capability within the operating room in a much less expensive way. And then if you look at another set of circumstances where people don't have a hybrid room at all, but do want to be able to offer standard EVAR

to their patients, and perhaps maybe even basic FEVAR, if there is such a thing, and we could use good quality imaging to do that in the absence of an actual hybrid room. That would be extremely valuable to be able to extend good quality care

to patients in under-served areas. So I just was mentioning that we can use this and Tara Mastracci was talking yesterday about how happy she is with her new room where she has the use of CYDAR and an excellent C-arm and she feels that she is able to essentially run two rooms,

two hybrid rooms at once, using the full hybrid room and the C-arm hybrid room. Here's just one case of Dr. Goverde's. A vascular case that he did on a mobile C-arm with aortoiliac occlusive disease and he places kissing stents

using a CYDAR EV and a C-arm. And he used five mils of iodinated contrast. So let's talk about a little bit of data. This is out of Blain Demorell and Tara Mastrachi's group. And this is use of fusion technology in EVAR. And what they found was that the use of fusion imaging

reduced air kerma and DSA runs in standard EVAR. We also looked at our experience recently in EVAR and FEVAR and we compared our results. Pre-availability of image based fusion CT and post image based fusion CT. And just to clarify,

we did have the mechanical product that Phillip's offers, but we abandoned it after using it a half dozen times. So it's really no image fusion versus image fusion to be completely fair. We excluded patients that were urgent/emergent, parallel endographs, and IBEs.

And we looked at radiation exposure, contrast use, fluoro time, and procedure time. The demographics in the two groups were identical. We saw a statistically significant decrease in radiation dose using image based fusion CT. Statistically a significant reduction in fluoro time.

A reduction in contrast volume that looks significant, but was not. I'm guessing because of numbers. And a significantly different reduction in procedure time. So, in conclusion, image based 3D fusion CT decreases radiation exposure, fluoro time,

and procedure time. It does enable 3D overlays in all X-Ray sets, including mobile C-arm, expanding our capabilities for endovascular work. And image based 3D fusion CT has the potential to reduce costs

and improve clinical outcomes. Thank you.

- I'd like the thank Doctor Veith for inviting me back to speak. I have no disclosures, we will be discussing some slight off-label use of the anitcoagulants. As we all know, acute limb ischemia occurs as a result of acute thrombosis of a native artery or bypass graft or embolism from a proximal

source, dissection, or trauma. The incidence is not insignificant, 15 cases per 100 000 persons per year, or interestingly about 10 to 16% of our vascular workload. Despite the relative frequency of this condition, there are relatively few guidelines to

guide us for anticoagulation therapy. The last set of guidelines for the American College of Chest Physicians regarding PAD gives some very brief, generic recommendations from 2012. They state, suggest immediate systemic anticoagulation with unfractionated heparin.

We suggest reperfusion over no reperfusion, which seems pretty obvious to an audience of vascular specialists. One of the challenges with acute limb ischemia is that it is a fairly heterogenous group. It can be thrombosis or embolism to the aorticiliac segments to the infrainguinal segments, and

there's also the patients who develop ALI from trauma. So we actually looked at the various phases of anticoagulation for acute limb ischemia and then we do, as with many institutions, utilize intravenous heparin at the time of the diagnosis, as well as obviously at the time of surgery,

but we found that there was a significant variation with regard to the early, post-operative anticoagulation regimens. One option is to give therapeutic intravenous heparin on an adjusted dose, but what we found in a significant minority of patients across the country actually,

is that people are giving this fixed mini-dose 500 unit an hour of heparin without any standardization or efficacy analysis. Then, obviously you go the long-term anticoagulation. We reviewed 123 patients who had ALI at our institution, who underwent surgical revascularization.

And they had the typical set of comorbidities you might expect in someone who has PAD or atheroembolism. In these patients, the Rutherford Classification was viable or marginally threatened in the majority, with about 25% having immediately threatened limb.

Various procedures were performed for these patients, including thromboembolectomy in the majority, bypass operations, angioplasty and stenting was performed in the significant minority and then primary amputation in the various selects few. We divided these patients into

the first four days of anticoagulation. Therapeutic with unfractionated heparin early on versus subtherapeutic or this mini-dose unfractionated heparin and we found that 29% of our patients were receiving the mini-dose unfractionated heparin, again without much efficacy analysis.

We used the International Society for Thrombosis and Haemostasis Anticoagulation Outcome Guidelines to look at the ischemic complications, as well as major and minor bleeding for these patients, and we identified actually not a significant rate of difference between the

subtherapeutic category and the therapeutic category of patients, with regard to mortality, with regard to recurrent limb ischemia, MI, VTE, or stroke, major amputation, and we actually didn't find because it's a fairly small study, any significant difference in major or minor bleeding for these patients.

So, we do feel that this small study did justify some efficacy of mini-dose unfractionated heparin because we didn't find that it was causing recurrent lower extremity thromboembolsim in these patients. Now on to long-term anticoagulation, for these patients, after that first three or four days

after the surgery, the options are long-term vitamin K antagonists, the DOAC's or vitamin K antagonists if you have atrial arrhythmia, or in the patients who had no other comorbidities, there really is not much guidance until recently. The compass trial was recently published in 2018

in stable PAD and carotid disease patients, identifying that rivaroxaban plus aspirin had a significant benefit over aspirin alone in patients who had stable PAD. And then, an upcoming trial, which is still ongoing currently in patients who underwent recent

revascularization, whether open or endo, is hopefully going to demonstrate that rivaroxaban, again has a role in patients with lower extremity ischemia. So in conclusion, there is relatively a scarcity of clinical data to help guide anticoagulation after acute limb ischemia.

Unfractionated heparin pre and intraop are standardized, but postop anticoagulation is quite variable. The mini-dose, we consider to be a reasonable option in the first few days to balance bleeding versus rethrombrosis, and fortunately we are having larger randomized clinical trials to help demonstrate the benefit of the DOACs and

aspirin in patients who are stable or post-revascularization for PAD, thank you.

- Thank you for asking me to speak. Thank you Dr Veith. I have no disclosures. I'm going to start with a quick case again of a 70 year old female presented with right lower extremity rest pain and non-healing wound at the right first toe

and left lower extremity claudication. She had non-palpable femoral and distal pulses, her ABIs were calcified but she had decreased wave forms. Prior anterior gram showed the following extensive aortoiliac occlusive disease due to the small size we went ahead and did a CT scan and confirmed.

She had a very small aorta measuring 14 millimeters in outer diameter and circumferential calcium of her aorta as well as proximal common iliac arteries. Due to this we treated her with a right common femoral artery cutdown and an antegrade approach to her SFA occlusion with a stent.

We then converted the sheath to a retrograde approach, place a percutaneous left common femoral artery access and then placed an Endologix AFX device with a 23 millimeter main body at the aortic bifurcation. We then ballooned both the aorta and iliac arteries and then placed bilateral balloon expandable

kissing iliac stents to stent the outflow. Here is our pre, intra, and post operative films. She did well. Her rest pain resolved, her first toe amputation healed, we followed her for about 10 months. She also has an AV access and had a left arterial steel

on a left upper extremity so last week I was able to undergo repeat arteriogram and this is at 10 months out. We can see that he stent remains open with good flow and no evidence of in stent stenosis. There's very little literature about using endografts for occlusive disease.

Van Haren looked at 10 patients with TASC-D lesions that were felt to be high risk for aorta bifem using the Endologix AFX device. And noted 100% technical success rate. Eight patients did require additional stent placements. There was 100% resolution of the symptoms

with improved ABIs bilaterally. At 40 months follow up there's a primary patency rate of 80% and secondary of 100% with one acute limb occlusion. Zander et all, using the Excluder prothesis, looked at 14 high risk patients for aorta bifem with TASC-C and D lesions of the aorta.

Similarly they noted 100% technical success. Nine patients required additional stenting, all patients had resolution of their symptoms and improvement of their ABIs. At 62 months follow up they noted a primary patency rate of 85% and secondary of 100

with two acute limb occlusions. The indications for this procedure in general are symptomatic patient with a TASC C or D lesion that's felt to either be a high operative risk for aorta bifem or have a significantly calcified aorta where clamping would be difficult as we saw in our patient.

These patients are usually being considered for axillary bifemoral bypass. Some technical tips. Access can be done percutaneously through a cutdown. I do recommend a cutdown if there's femoral disease so you can preform a femoral endarterectomy and

profundaplasty at the same time. Brachial access is also an alternative option. Due to the small size and disease vessels, graft placement may be difficult and may require predilation with either the endograft sheath dilator or high-pressure balloon.

In calcified vessels you may need to place covered stents in order to pass the graft to avoid rupture. Due to the poor radial force of endografts, the graft must be ballooned after placement with either an aortic occlusion balloon but usually high-pressure balloons are needed.

It usually also needs to be reinforced the outflow with either self-expanding or balloon expandable stents to prevent limb occlusion. Some precautions. If the vessels are calcified and tortuous again there may be difficult graft delivery.

In patients with occluded vessels standard techniques for crossing can be used, however will require pre-dilation before endograft positioning. If you have a sub intimal cannulation this does put the vessel at risk for rupture during

balloon dilation. Small aortic diameters may occlude limbs particularly using modular devices. And most importantly, the outflow must be optimized using stents distally if needed in the iliac arteries, but even more importantly, assuring that you've

treated the femoral artery and outflow to the profunda. Despite these good results, endograft use for occlusive disease is off label use and therefor not reimbursed. In comparison to open stents, endograft use is expensive and may not be cost effective. There's no current studies looking

into the cost/benefit ratio. Thank you.

- Thank you very much. I'm going to talk on Improper and Suboptimal Antiplatelet Therapy which is probably currently the standard on most carotid angioplasty stent trials and I'm going to show you how it could potentially affect all of the results we have seen so far. I have nothing to disclose.

So introduction, based on the composite end point of stroke/death in our technical trials, they're always, in all randomized trials Endarterectomy always did marginally better than Carotid angioplasty and stenting. However, a small shift, just about a one person shift

could make carotid artery stenting better could shift the results of all these carotid stent trials. Let's just look at CREST. I think it's the gold standard for randomized trial comparing endarterectomy with stenting. You can see the combined death, streak and MI rate.

For endarterectomy, it's 6.8%, for CAS, 7.2%. For stroke, again 2.3, 4.1. Again, it's a one person shift in a direction of making stents better could actually show that stents were favorable, but comparable to it, not just inferior.

Now if you look at the data on CREST, it's very interesting that the majority of the strokes, about 80% of the strokes happened after about 24 hours. In fact, most of them happened on the third day period. So it wasn't a technical issue. You know, the biggest issue with current stenting

that we find is that we have filters, we have floor reversal. They're very worried about the time we place the stent, that we balloon, pre- and post-, but it wasn't a technical issue. Something was happening after 24 hours.

Another interesting fact that no one speaks about is if you look at the CREST data a little bit in more detail, most of the mortality associated with the stenting was actually associated with an access site bleed.

So if you could really decrease the late strokes, if you can decrease the access site bleeds, I think stents can be performed better than endarterectomies. The study design for all stent trials, there was a mandatory dual antiplatelet therapy.

Almost all patients had to be on aspirin and Plavix and on CREST, interestingly, they had to be on 75 milligrams BID for Plavix so they were all on very high dose Plavix. Now here's the interesting thing about Plavix that most people don't know.

Plavix is what is called a pro-drug. It requires to be converted to its active component by the liver for antiplatelet effect. And the particular liver enzyme that converts Plavix to its active metabolic enzyme is very variable patient to patient

and you're born that way. You're either born where you can convert its active metabolite or you can't convert it to its active metabolite and a test that's called 2C19 is actually interesting approved and covered by Medicare and here's the people

that read the black box warning for Plavix, that looked at the package insert. I just cut and paste this on the package that said for Plavix. I'm just showing you a few lines from the package insert. Now next to aspirin, it's the commonest prescribed drug

by vascular specialists, but most people probably have not looked at the package insert that says effectiveness of Plavix depends on activation by a liver enzyme called 2C19 and goes on to say that tests are available to identify to 2C19 genotype.

And then they go on to actually give you a recommendation on the package insert that says consider alternative treatment strategies in patients identified as 2C19 poor metabolizers. Now these are the people who cannot metabolize Plavix and convert them to its active metabolite.

So let's look at the actual incidents. Now we know there is resistance to, in some patients, to aspirin, but the incident is so small it doesn't make worth our time or doesn't make it worth the patient's outcome to be able to test everyone for aspirin resistance,

but look at the incidents for Plavix resistance. Again, this is just a slide explaining what does resistance mean so if you're a normal metabolizer, which we hope that most of us would be, you're going to expect advocacy from Plavix at 75 milligrams once a day.

Other hand, let's say you're a rapid or ultrarapid metabolizer. You have a much higher risk of bleeding. And then if you go to the other side where you are normal, intermediate or poor metabolizer, you're not going to convert Plavix to its active metabolite

and poor metabolizers, it's like giving a placebo. And interestingly, I'm a poor metabolizer. I got myself tested. If I ever have a cardiac interventionalist give me Plavix, they're giving me a placebo. So let's look at the actual incidents

of all these subsets in patients and see whether that's going to be an issue. So we took this from about 7,000 patients and interestingly in only about 40%, NM stands for nominal metabolizer or normal metabolizers. So only 40% get the expected efficacy of Plavix.

Let's look at just the extremes. Let's just assume people with normal metabolizers, normal intermediate and the subgroup between the ultra rapid, the normals, they're all going to respond well to Plavix. Let's just look at the extremes.

Ultra rapid and poor metabolizers. So these are the people who are going to convert Plavix to a much higher concentration of its active metabolite, but have a much higher risk of bleeding. Ultra rapid metabolizers. Poor metabolizers, Plavix doesn't work.

4%, 3%. That's not a small incidence. Now in no way am I saying that carotid stent trials itselves are totally based on Plavix resistance, but just look at the data from CREST. Let's say the patients with poor metabolizers,

that's 3%, so these people did not get Plavix. Plavix does not affect you in doses of up to 600 milligram for people with poor metabolizers. Incidents of embolic events in CREST trial for carotid stents was 4%. This happened after three days.

I believe it's possibly related to platelet debris occurring in the stent on people who did not receive a liquid anti-platelet therapy. How about the people who had the groin bleed? Remember I told you that access site bleeds were most highly predictable mortality.

If you're the ultra rapid metabolizers, that incidence was 4%. So these were the people that convert Plavix with a very high dose of active metabolite, very high risk of bleeding. Access site bleed rate,

if you look at the major/minor rates, 4.1%, very close to the ultra rapid metabolizers. So fact remains that carotid angioplasty stenting post procedure events are highly dependent on appropriate antiplatelet therapy to minimize embolic events and to decrease groin bleeds.

So in conclusion, if we just included 2C19 normal metabolizers, as was recommended by the packaging insert, so just test the people, include the people on normal metabolizers, exclude the rest, we are probably going to shift the results in favor of carotid angioplasty and stenting.

Results of all carotid angioplasty stent trials need to be questioned as a significant number of patients in the carotid angioplasty stent arm did not receive appropriate antiplatelet therapy. Thank you very much.

- Thank you very much. So this is more or less a teaser. The outcome data will not be presented until next month. It's undergoing final analysis. So, the Vici Stent was the stent in the VIRTUS Trial. Self-expanding, Nitinol stent,

12, 14, and 16 in diameter, in three different lengths, and that's what was in the trial. It is a closed-cell stent, despite the fact that it's closed-cell, the flexibility is not as compromised. The deployment can be done from the distal end

or the proximal end for those who have any interest, if you're coming from the jugular or not in the direction of flow, or for whatever reason you want to deploy it from this end versus that end, those are possible in terms of the system. The trial design is not that different than the other three

now the differences, there are minor differences between the four trials that three completed, one soon to be complete, the definitions of the endpoints in terms of patency and major adverse events were very similar. The trial design as we talked about, the only thing

that is different in this study were the imaging requirements. Every patient got a venogram, an IVUS, and duplex at the insertion and it was required at the completion in one year also, the endpoint was venographic, and those who actually did get venograms,

they had the IVUS as well, so this is the only prospective study that will have that correlation of three different imagings before, after, and at follow-up. Classification, everybody's aware, PTS severity, everybody's aware, the endpoints, again as we talked about, are very similar to the others.

The primary patency in 12 months was define this freedom from occlusion by thrombosis or re-intervention. And the safety endpoints, again, very similar to everybody else. The baseline patient characteristics, this is the pivotal, as per design, there were 170 in the pivotal

and 30 in the feasibility study. The final outcome will be all mixed in, obviously. And this is the distribution of the patients. The important thing here is the severity of patients in this study. By design, all acute thrombotic patients, acute DVT patients

were excluded, so anybody who had history of DVT within three months were excluded in this patient. Therefore the patients were all either post-thrombotic, meaning true chronic rather than putting the acute patients in the post-thrombotic segment. And only 25% were Neville's.

That becomes important, so if you look at the four studies instead of an overview of the four, there were differences in those in terms on inclusion/exclusion criteria, although definitions were similar, and the main difference was the inclusion of the chronics, mostly chronics, in the VIRTUS study, the others allowed acute inclusion also.

Now in terms of definition of primary patency and comparison to the historical controls, there were minor differences in these trials in terms of what that historical control meant. However, the differences were only a few percentages. I just want to remind everyone to something we've always known

that the chronic post-thrombotics or chronic occlusions really do the worst, as opposed to Neville's and the acute thrombotics and this study, 25% were here, 75% were down here, these patients were not allowed. So when the results are known, and out, and analyzed it's important not to put them in terms of percentage

for the entire cohort, all trials need to report all of these three categories separately. So in conclusion venous anatomy and disease requires obviously dedicated stent. The VIRTUS feasibility included 30 with 170 patients in the pivotal cohort, the 12 months data will be available

in about a month, thank you.

- [Nicos] Thanks so much. Good afternoon everybody. I have no disclosures. Getting falsely high velocities because of contralateral tight stenosis or occlusion, our case in one third of the people under this condition, high blood pressure, tumor fed by the carotid, local inflammation, and rarely by arteriovenous fistula or malformation.

Here you see a classic example, the common carotid, on the right side is occluded, also the internal carotid is occluded, and here you're getting really high velocity, it's 340, but if you visually look at the vessel, the vessel is pretty wide open. So it's very easy to see this discordance

between the diameter and the velocity. For occasions like this I'm going to show you with the ultrasound or other techniques, planimetric evaluation and if I don't go in trials, hopefully we can present next year. Another condition is to do the stenosis on the stent.

Typically the error here is if you measure the velocity outside the stent, inside the stent, basically it's different material with elastic vessel, and this can basically bring your ratio higher up. Ideally, when possible, you use the intra-stent ratio and this will give you a more accurate result.

Another mistake that is being done is that you can confuse the external with the internal, particularly also we found out that only one-third of the people internalized the external carotid, but here you should not make this mistake because you can see the branches obviously, but really, statistically speaking, if you take 100

consecutively occluded carotids, by statistical chance 99% of the time or more it will be not be an issue, that's common sense. And of course here I have internalization of the external, let's not confuse there too, but here we don't have any

stenosis, really we have increased velocity of the external because a type three carotid body tumor, let's not confuse this from this issue. Another thing which is a common mistake people say, because the velocity is above the levels we put, you see it's 148 and 47, this will make you with a grand criteria

having a 50% stenosis, but it's also the thing here is just tortuosity, and usually on the outer curve of a vessel or in a tube the velocity is higher. Then it can have also a kink, which can produce the a mild kink like this

on here, it can make the stenosis appear more than 50% when actually the vessel does have a major issue. This he point I want to make with the FMD is consistently chemical gradual shift, because the endostatin velocity is higher

than people having a similar degree of stenosis. Fistula is very rare, some of our over-diligent residents sometimes they can connect the jugular vein with roke last year because of this. Now, falsely low velocities because of proximal stenosis of

the Common Carotid or Brachiocephalic Artery, low blood pressure, low cardiac output, valve stenosis efficiency, stroke, and distal ICA stenosis or occlusion, and ICA recanalization. Here you see in a person with a real tight stenosis, basically the velocity is very low,

you don't have a super high velocity. Here's a person with an occlusion of the Common Carotid, but then the Internal Carotid is open, it flooded vessels from the external to the internal, and that presses a really tight stenosis of the external or the internal, but the velocities are low just because

the Common Carotid is occluded. Here is a phenomenon we did with a university partner in 2011, you see a recanalized Carotid has this kind of diameter, which goes all the way to the brain and a velocity really low but a stenosis really tight. In a person with a Distal dissection, you have low velocity

because basically you have high resistance to outflow and that's why the velocities are low. Here is an occlusion of the Brachiocephalic artery and you see all the phenomena, so earlier like the Common Carotid, same thing with the Takayasu's Arteritis, and one way I want to finish

this slide is what you should do basically when the velocity must reduce: planimetric evaluation. I'll give you the preview of this idea, which is supported by intracarotid triplanar arteriography. If the diameter of the internal isn't two millimeters, then it's 95% possible the value for stenosis,

regardless of the size of the Internal Carotid. So you either use the ICAs, right, then you're for sure a good value, it's a simple measurement independent of everything. Thank you very much.

- Thanks Dr. Weaver. Thank you Dr. Reed for the invitation, once again, to this great meeting. These are my disclosures. So, open surgical repair of descending aortic arch disease still carries some significant morbidity and mortality.

And obviously TEVAR as we have mentioned in many of the presentations has become the treatment of choice for appropriate thoracic lesions, but still has some significant limitations of seal in the aortic arch and more techniques are being developed to address that.

Right now, we also need to cover the left subclavian artery and encroach or cover the left common carotid artery for optimal seal, if that's the area that we're trying to address. So zone 2, which is the one that's,

it is most commonly used as seal for the aortic arch requires accurate device deployment to maximize the seal and really avoid ultimately, coverage of the left common carotid artery and have to address it as an emergency. Seal, in many of these cases is not maximized

due to the concern of occlusion of the left common carotid artery and many of the devices are deployed without obtaining maximum seal in that particular area. Failure of accurate deployment often leads to a type IA endoleak or inadvertent coverage

of the left common carotid artery which can become a significant problem. The most common hybrid procedures in this group of patients include the use of TEVAR, a carotid-subclavian reconstruction and left common carotid artery stenting,

which is hopefully mostly planned, but many of the times, especially when you're starting, it may be completely unplanned. The left common carotid chimney has been increasingly used to obtain a better seal

in this particular group of patients with challenging arches, but there's still significant concerns, including patients having super-vascular complications, stroke, Type A retrograde dissections and a persistent Type IA endoleak

which can be very challenging to be able to correct. There's limited data to discuss this specific topic, but some of the recent publications included a series of 11 to 13 years of treatment with a variety of chimneys.

And these publications suggest that the left common carotid chimneys are the most commonly used chimneys in the aortic arch, being used 76% to 89% of the time in these series. We can also look at these and the technical success

is very good. Mortality's very low. The stroke rate is quite variable depending on the series and chimney patency's very good. But we still have a relatively high persistent

Type IA endoleak on these procedures. So what can we do to try to improve the results that we have? And some of these techniques are clearly applicable for elective or emergency procedures. In the elective setting,

an open left carotid access and subclavian access can be obtained via a supraclavicular approach. And then a subclavian transposition or a carotid-subclavian bypass can be performed in preparation for the endovascular repair. Following that reconstruction,

retrograde access to left common carotid artery can be very helpful with a 7 French sheath and this can be used for diagnostic and therapeutic purposes at the same time. The 7 French sheath can easily accommodate most of the available covered and uncovered

balloon expandable stents if the situation arises that it's necessary. Alignment of the TEVAR is critical with maximum seal and accurate placement of the TEVAR at this location is paramount to be able to have a good result.

At that point, the left common carotid artery chimney can be deployed under control of the left common carotid artery. To avoid any embolization, the carotid can be flushed, primary repaired, and the subclavian can be addressed

if there is concern of a persistent retrograde leak with embolization with a plug or other devices. The order can be changed for the procedure to be able to be done emergently as it is in this 46 year old policeman with hypertension and a ruptured thoracic aneurism.

The patient had the left common carotid access first, the device deployed appropriately, and the carotid-subclavian bypass performed in a more elective fashion after the rupture had been addressed. So, in conclusion, carotid chimney's and TEVAR

combination is a frequently used to obtain additional seal on the aortic arch, with pretty good results. Early retrograde left common carotid access allows safe TEVAR deployment with maximum seal,

and the procedure can be safely performed with low morbidity and mortality if we select the patients appropriately. Thank you very much.

- Good morning, thank you very much to Dr. Veith and Professor Veith and the organizers. So this is real holography. It's not augmented reality. It's not getting you separated from the environment that you're in. This is actually taking the 3D out of the screen

so the beating heart can be held in the palm of your hand without you having to wear any goggles or anything else and this is live imaging. It can be done intra-procedure. This is the Holoscope-i and the other one is the Holoscope-x

where in fact you can take that actually 3D hologram that you have and you can implant it in the patient and if you co-register it correctly then you can actually do the intervention in the patient

make a needle tract to the holographic needle and I'm going to limit this to just now what we're actually doing at the moment and not necessarily what the future can be. This is ultimate 3D visualization, true volumes floating in the air.

This is a CT scan. So it started working, So we get rid of the auto-segmented and you can just interact. It's floating 45 centimeters away from you and you can just hold the patient's anatomy here and you can slice into the anatomy.

This is for instance a real CT of an aorta with the aortic valve which they wanted to analyze for a core valve procedure. This is done by Phelps. If you take the information

and they've looked at the final element analysis and interaction between the stem and the tissue. So here you can make measurements in real time. So if you did the 3D rotation and geography and you had the aorta and you wanted to put in a stent graft EVAR TVAR, and you would see,

and you could put in a typical tuber that you would do, and you could see how it, and this is a dynamic hologram, so you can see how it would open up, you can mark where your fenestration's chimney is and all that type of stuff would be. And you can move it around, and you have

a complete intuitive understanding of a, can we go to the next slide please, I can't, it seems to be clicking, thank you. So how do we do all this? Well, to create a hologram, what you need to do is just conceptualize it as printing in light.

Like if you had plastic and you took the XYZ data and you just put it into a 3D printer, and it would print it for you in light, then you'd go, Okay, so I understand, if it was printed for you in plastic then you'd understand. But imagine it's printing in light.

So we have every single piece of light focused, each photon is focused so that you can see it with a naked eye, in a particular place, but the difference is that it's totally sterile, you don't have to take off your gloves, you don't have to use a mouse,

you can interact with it directly. And all the XYZ data is 100% in place, so we've just seen a beautiful demonstration of augmented reality, and in augmented reality, you have to wear something, it isolates you from the environment that you're in, and it's based on

stereoscopy, and stereoscopy is how you see 3D movies, and how you see augmented reality, is by taking two images and fusing them in one focal plane. But you can't touch that image, because if you look at me now, you can see me very well, but if you hold your finger up 45 centimeters

and you focus on your finger, I become blurred. And so, you can only focus in one plane, you can't touch that image, because that image is distant from you, and it's a fused image, so you have the focus plane and you have the convergence plane, and this is an illusion

of 3D, and it's very entertaining, and it can be very useful in medical imaging, but in intra-operative procedures it has to be 100% accurate. So you saw a very beautiful example in the previous talk of augmented reality, where you have gesturing, where you can actually gesture with the image,

you can make it bigger, you can make it smaller. But what RealView does by creating real holography, which is all the XYZ data, is having it in the palm of your hand, with having above 20 focal planes, here, very very close to your eye, and that in another way, of having all those focal planes not only actually lets you

do the procedure but prevents nausea and having a feeling of discomfort because the image is actually there as of having the illusion of the images there. So just to go back, all RealView imaging is doing, is it's not changing your 3D RA cone, BMCT, MRI,

we can do all those XYZ datas and we can use them and we can present them, all we're doing, so you use your acquisition, we're just taking that, and we're breaking open the 3D displays and seeing all that 3D data limited in the 2D screen, let's set it free and have it floating in the air.

So we have the holoscope-i for structural cardiology and electrophysiology, and obviously the holoscope-x, which makes the patient x-rayed, completely visible. So its an over the head, this is now, obviously, free-standing when somebody buys us like Phillips or Siemens, it will be integrated into your lab,

come down from the ceiling, it's an independent system, and you just have a visor that you look through, which just goes up and down whenever you want to use it. You can interact with it the same as you do with your iPhone you can visualize, you can rotate, you can mark, you can slice, you can measure, as I showed you

some examples of it, and you can do this by voice as well, you just talk to it, you say slice and you slice it with your hand, it recognizes everybody's hand, there's no delay for whatever you're imaging. So structural cardiac procedures, this is what

a mitral valve will look like, floating in the air in front of you, you can see the anterior leaflet, the posterior leaflet. And once the catheter is inside and you're guiding the catheter inside the procedure, you can turn on your doppler, you'll be able to see that the catheter

movements, so for someone doing a mitral clip, or whatever, this would be very very useful. This is an electrophysiological procedure, and you can see how the catheter moves, when the catheter will move, and obviously, as my previous speaker was saying, you are appreciating 3D in a 2D screen,

so it's very difficult to appreciate, you'll have to take my word for it. But I think you can see dynamic colography at this quality, that you can interact with, that is something that is very special, we've presented at a number of conferences,

including at Veith, and we've already done a first in man, and the most exciting thing for now, is just this week, the first machine was installed at Toronto general, at the Peter Munk Cardiac Center, and they've done their first case, and so now we are launching and clinical trials in 2018, and hopefully,

I'll have something which is more vascular relevant, at the next time, Veith 2019, thank you very much.

- [Speaker] Good morning everybody thanks for attending the session and again thanks for the invitation. These are my disclosures. I will start by illustrating one of the cases where we did not use cone beam CT and evidently there were numerous mistakes on this

from planning to conducting the case. But we didn't notice on the completion of geography in folding of the stent which was very clearly apparent on the first CT scan. Fortunately we were able to revise this and have a good outcome.

That certainly led to unnecessary re intervention. We have looked at over the years our usage of fusion and cone beam and as you can see for fenestrated cases, pretty much this was incorporated routinely in our practice in the later part of the experience.

When we looked at the study of the patients that didn't have the cone beam CT, eight percent had re intervention from a technical problem that was potentially avoidable and on the group that had cone beam CT, eight percent had findings that were immediately revised with no

re interventions that were potentially avoidable. This is the concept of our GE Discovery System with fusion and the ability to do cone beam CT. Our protocol includes two spins. First we do one without contrast to evaluate calcification and other artifacts and also to generate a rotational DSA.

That can be also analyzed on axial coronal with a 3D reconstruction. Which essentially evaluates the segment that was treated, whether it was the arch on the arch branch on a thoracoabdominal or aortoiliac segment.

We have recently conducted a prospective non-randomized study that was presented at the Vascular Annual Meeting by Dr. Tenario. On this study, we looked at findings that were to prompt an immediate re intervention that is either a type one

or a type 3 endoleak or a severe stent compression. This was a prospective study so we could be judged for being over cautious but 25% of the procedures had 52 positive findings. That included most often a stent compression or kink in 17% a type one or three endoleak

in 9% or a minority with dissection and thrombus. Evidently not all this triggered an immediate revision, but 16% we elected to treat because we thought it was potentially going to lead to a bad complication. Here is a case where on the completion selective angiography

of the SMA this apparently looks very good without any lesions. However on the cone beam CT, you can see on the axial view a dissection flap. We immediately re catheterized the SMA. You note here there is abrupt stop of the SMA.

We were unable to catheterize this with a blood wire. That led to a conversion where after proximal control we opened the SMA. There was a dissection flap which was excised using balloon control in the stent as proximal control.

We placed a patch and we got a good result with no complications. But considerably, if this patient was missed in the OR and found hours after the procedure he would have major mesenteric ischemia. On this study, DSA alone would have missed

positive findings in 34 of the 43 procedures, or 79% of the procedures that had positive findings including 21 of the 28 that triggered immediate revision. There were only four procedures. 2% had additional findings on the CT

that were not detectable by either the DSA or cone beam CT. And those were usually in the femoro puncture. For example one of the patients had a femoro puncture occlusion that was noted immediately by the femoro pulse.

The DSA accounts for approximately 20% of our total radiation dose. However, it allows us to eliminate CT post operatively which was done as part of this protocol, and therefore the amount of radiation exposed for the patient

was decreased by 55-65% in addition to the cost containment of avoiding this first CT scan in our prospective protocol. In conclusion cone beam CT has allowed immediate assessment to identify technical problems that are not easily detectable by DSA.

These immediate revisions may avoid unnecessary re interventions. What to do if you don't have it? You have to be aware that this procedure that are complex, they are bound to have some technical mistakes. You have to have incredible attention to detail.

Evidently the procedures can be done, but you would have to have a low threshold to revise. For example a flared stent if the dilator of the relic gleam or the dilator of you bifurcated devise encroach the stent during parts of the procedure. Thank you very much.

(audience applauding)

- Thank you and thanks again Frank for the kind invitation to be here another year. So there's several anatomic considerations for complex aortic repair. I wanted to choose between fenestrations or branches,

both with regards to that phenotype and the mating stent and we'll go into those. There are limitations to total endovascular approaches such as visceral anatomy, severe angulations,

and renal issues, as well as shaggy aortas where endo solutions are less favorable. This paper out of the Mayo Clinic showing that about 20% of the cases of thoracodynia aneurysms

non-suitable due to renal issues alone, and if we look at the subset that are then suitable, the anatomy of the renal arteries in this case obviously differs so they might be more or less suitable for branches

versus fenestration and the aneurysm extent proximally impacts that renal angle. So when do we use branches and when do we use fenestrations? Well, overall, it seems to be, to most people,

that branches are easier to use. They're easier to orient. There's more room for error. There's much more branch overlap securing those mating stents. But a branch device does require

more aortic coverage than a fenestrated equivalent. So if we extrapolate that to juxtarenal or pararenal repair a branched device will allow for much more proximal coverage

than in a fenestrated device which has, in this series from Dr. Chuter's group, shows that there is significant incidence of lower extremity weakness if you use an all-branch approach. And this was, of course, not biased

due to Crawford extent because the graft always looks the same. So does a target vessel anatomy and branch phenotype matter in of itself? Well of course, as we've discussed, the different anatomic situations

impact which type of branch or fenestration you use. Again going back to Tim Chuter's paper, and Tim who only used branches for all of the anatomical situations, there was a significant incidence of renal branch occlusion

during follow up in these cases. And this has been reproduced. This is from the Munster group showing that tortuosity is a significant factor, a predictive factor, for renal branch occlusion

after branched endovascular repair, and then repeated from Mario Stella's group showing that upward-facing renal arteries have immediate technical problems when using branches, and if you have the combination of downward and then upward facing

the long term outcome is impaired if you use a branched approach. And we know for the renals that using a fenestrated phenotype seems to improve the outcomes, and this has been shown in multiple trials

where fenestrations for renals do better than branches. So then moving away from the phenotype to the mating stent. Does the type of mating stent matter? In branch repairs we looked at this

from these five major European centers in about 500 patients to see if the type of mating stent used for branch phenotype grafts mattered. It was very difficult to evaluate and you can see in this rather busy graph

that there was a combination used of self-expanding and balloon expandable covered stents in these situations. And in fact almost 2/3 of the patients had combinations in their grafts, so combining balloon expandable covered stents

with self expanding stents, and vice versa, making these analyses very very difficult. But what we could replicate, of course, was the earlier findings that the event rates with using branches for celiac and SMA were very low,

whereas they were significant for left renal arteries and if you saw the last session then in similar situations after open repair, although this includes not only occlusions but re-interventions of course.

And we know when we use fenestrations that where we have wall contact that using covered stents is generally better than using bare stents which we started out with but the type of covered stent

also seems to matter and this might be due to the stiffness of the stent or how far it protrudes into the target vessel. There is a multitude of new bridging stents available for BEVAR and FEVAR: Covera, Viabahn, VBX, and Bentley plus,

and they all seem to have better flexibility, better profile, and better radial force so they're easier to use, but there's no long-term data evaluating these devices. The technical success rate is already quite high for all of these.

So this is a summary. We've talked using branches versus fenestration and often a combination to design the device to the specific patient anatomy is the best. So in summary,

always use covered stents even when you do fenestrated grafts. At present, mix and match seems to be beneficial both with regards to the phenotype and the mating stent. Short term results seem to be good.

Technical results good and reproducible but long term results are lacking and there is very limited comparative data. Thank you. (audience applauding)

- And thanks to Dr. Veith for the opportunity to get involved. Here's my disclosures. Like so many in the audience, for years and years we've had awesome results with the AngioJet from Boston Sci. We know that this rheolytic system works quite well.

However it has a black box warning for PE due to the hemolysis and the adenosine that can be extruded out. It's oftentimes not stand alone. It's not used for stroke and there can be some renal issues. But we've had excellent results with it over the years,

but at the end of the day often times you still need lytics. And I think Professor Davies just eluded to the potential problems not only medical, but legal as well of lytics. Therefore for the past four plus years we've utilized this as well as other thrombectomy devices.

This is the Indigo device from Penumbra. I'm certain by now most of your are familiar with it, but if not what it is it's a braided catheter that's very atraumatic and soft at the tip. It can come straight in or torqued so you can have some directionality to it.

And then what it also has is this separator technology which is really just like a glorified pipe cleaner to be honest. You're going to go in and out with this device as I'll show you here in a second, to clear the lumen while you're

allowing for continuous aspiration through this system. We learned from our neurosurgery colleagues who utilized typically the CAT five, sometimes six for their stroke patients, but now there's CAT three, five, six, and eight. And within the next probably three to four months

there's going to be CAT 10 or possibly even 12 out there. This is what you have. It's all pretty simple. You cross your lesion with the wire. You then bring your catheter across. You connect it to this suction device,

hit the green button and away you go. You get maximal aspiration. And what's nice about it is in particular for the CAT eight with the XTORQ, as you can see you can get out to vessel 25 millimeters in diameter.

So essentially a cava. This shows you how powerful this is. This is one of my patient's with a standard nitinol stent. A Zilver PTX was occluded and you can see how powerful this device

is with maximal aspiration. Turn it off and obviously the self expanding stent goes right back to normal. So after our results with the ALI patients, and we presented our data at the Midwest meeting in St. Louis earlier this fall,

we start looking at our DVT patients and here you can see an effort thrombosis. Somebody here. We went eight French basilic. Ultrasound guided. Put an eight French Indigo in and with no lytics,

were able to clean this out. We then went on to, I put him on a DOAC. Today I'd probably use Lovenox for two weeks. And then he went home. He's a 32 year old.

Went to Disney World with his family and then came back later on for is infraclavicular rib excision. Here's another one of my patients, Lena. She's a 19 year old who started her OPCs on the way back to Bellarmine College in Louisville.

And as you can see here, she is a likely underlying May Thurner lesion. Extensive of femoral DVT. As you look over here to the screen left to screen right, you can see that we crossed it, put our catheter up in the common iliac vein,

as as you can see we're twisting it around to get to the edges of the vessel, the whole iliofemoral system. Here's what you get afterwards. You get antegrade flow. Certainly there's no device yet that's perfect at this.

For this particular patient we gave her 14 milligrams of lytics then did our IVUS then did our wallstent. And she's done quite well. We use it for arms. We use it for legs.

We use it for filters as well as you can see here with this occluded filter. And often times the picture you're going to get is an underlying acute on chronic thrombosis here. And we later on came back and took that filter out. So I think there's no question there's less lytics with it.

Earlier this year we presented at the American Venous Forum in Tucson. Our initial experiences with vacuum-assisted thrombectomy for DVT. And what showed is that often times you can get antegrade flow as I'll show you here.

Some of them are single sessions. But more importantly just as efficacious as it is it's safe. You can see here that we had minimal blood loss, low transfusions, and here's our breakdown. As we use it for all venous pathologies as you can see.

So at the time when we looked at our first 20, you can see that there were some that were single session therapy. And that's before. We've now added the turbo pulse technique where you're going to lace it with

14 milligrams of TPA through a unifused catheter, wait 20 minutes, go around get some coffee, whatever you need to do, come back and then use the Indigo. So at the end of the day, I think as Professor Davies eluded to, there are major complications with lytics.

This is not what we need for our patients. So in 2018 we can either continue to load with dangerous lytics or minimize lytics, adopt continuous aspiration thrombectomy. It's your all's choice. So thanks so much.

- These are my disclosures. So central venous access is frequently employed throughout the world for a variety of purposes. These catheters range anywhere between seven and 11 French sheaths. And it's recognized, even in the best case scenario, that there are iatrogenic arterial injuries

that can occur, ranging between three to 5%. And even a smaller proportion of patients will present after complications from access with either a pseudoaneurysm, fistula formation, dissection, or distal embolization. In thinking about these, as you see these as consultations

on your service, our thoughts are to think about it in four primary things. Number one is the anatomic location, and I think imaging is very helpful. This is a vas cath in the carotid artery. The second is th

how long the device has been dwelling in the carotid or the subclavian circulation. Assessment for thrombus around the catheter, and then obviously the size of the hole and the size of the catheter.

Several years ago we undertook a retrospective review and looked at this, and we looked at all carotid, subclavian, and innominate iatrogenic injuries, and we excluded all the injuries that were treated, that were manifest early and treated with just manual compression.

It's a small cohort of patients, we had 12 cases. Eight were treated with a variety of endovascular techniques and four were treated with open surgery. So, to illustrate our approach, I thought what I would do is just show you four cases on how we treated some of these types of problems.

The first one is a 75 year-old gentleman who's three days status post a coronary bypass graft with a LIMA graft to his LAD. He had a cordis catheter in his chest on the left side, which was discovered to be in the left subclavian artery as opposed to the vein.

So this nine French sheath, this is the imaging showing where the entry site is, just underneath the clavicle. You can see the vertebral and the IMA are both patent. And this is an angiogram from a catheter with which was placed in the femoral artery at the time that we were going to take care of this

with a four French catheter. For this case, we had duel access, so we had access from the groin with a sheath and a wire in place in case we needed to treat this from below. Then from above, we rewired the cordis catheter,

placed a suture-mediated closure device, sutured it down, left the wire in place, and shot this angiogram, which you can see very clearly has now taken care of the bleeding site. There's some pinching here after the wire was removed,

this abated without any difficulty. Second case is a 26 year-old woman with a diagnosis of vascular EDS. She presented to the operating room for a small bowel obstruction. Anesthesia has tried to attempt to put a central venous

catheter access in there. There unfortunately was an injury to the right subclavian vein. After she recovered from her operation, on cross sectional imaging you can see that she has this large pseudoaneurysm

coming from the subclavian artery on this axial cut and also on the sagittal view. Because she's a vascular EDS patient, we did this open brachial approach. We placed a stent graft across the area of injury to exclude the aneurism.

And you can see that there's still some filling in this region here. And it appeared to be coming from the internal mammary artery. We gave her a few days, it still was patent. Cross-sectional imaging confirmed this,

and so this was eventually treated with thoracoscopic clipping and resolved flow into the aneurism. The next case is a little bit more complicated. This is an 80 year-old woman with polycythemia vera who had a plasmapheresis catheter,

nine French sheath placed on the left subclavian artery which was diagnosed five days post procedure when she presented with a posterior circulation stroke. As you can see on the imaging, her vertebral's open, her mammary's open, she has this catheter in the significant clot

in this region. To manage this, again, we did duel access. So right femoral approach, left brachial approach. We placed the filter element in the vertebral artery. Balloon occlusion of the subclavian, and then a stent graft coverage of the area

and took the plasmapheresis catheter out and then suction embolectomy. And then the last case is a 47 year-old woman who had an attempted right subclavian vein access and it was known that she had a pulsatile mass in the supraclavicular fossa.

Was noted to have a 3cm subclavian artery pseudoaneurysm. Very broad base, short neck, and we elected to treat this with open surgical technique. So I think as you see these consults, the things to factor in to your management decision are: number one, the location.

Number two, the complication of whether it's thrombus, pseudoaneurysm, or fistula. It's very important to identify whether there is pericatheter thrombus. There's a variety of techniques available for treatment, ranging from manual compression,

endovascular techniques, and open repair. I think the primary point here is the prevention with ultrasound guidance is very important when placing these catheters. Thank you. (clapping)

- Thank you very much and thank you Dr. Veith for the kind invite. Here's my disclosures, clearly relevant to this talk. So we know that after EVAR, it's around the 20% aortic complication rate after five years in treating type one and three Endoleaks prevents subsequent

secondary aortic rupture. Surveillance after EVAR is therefore mandatory. But it's possible that device-specific outcomes and surveillance protocols may improve the durability of EVAR over time. You're all familiar with this graph for 15 year results

in terms of re-intervention from the EVAR-1 trials. Whether you look at all cause and all re-interventions or life threatening re-interventions, at any time point, EVAR fares worse than open repair. But we know that the risk of re-intervention is different

in different patients. And if you combine pre-operative risk factors in terms of demographics and morphology, things are happening during the operations such as the use of adjuncts,

or having to treat intro-operative endoleak, and what happens to the aortic sac post-operatively, you can come up with a risk-prediction tool for how patients fare in the longer term. So the LEAR model was developed on the Engage Registry and validated on some post-market registries,

PAS, IDE, and the trials in France. And this gives a predictive risk model. Essentially, this combines patients into a low risk group that would have standard surveillance, and a higher risk group, that would have a surveillance plus

or enhanced surveillanced model. And you get individual patient-specific risk profiles. This is a patient with around a seven centimeter aneurysm at the time of repair that shows sac shrinkage over the first year and a half, post-operatively. And you can see that there's really a very low risk

of re-intervention out to five years. These little arrow bars up here. For a patient that has good pre-operative morphology and whose aneurysm shrinks out to a year, they're going to have a very low risk of re-intervention. This patient, conversely, had a smaller aneurysm,

but it grew from the time of the operation, and out to two and a half years, it's about a centimeter increase in the sac. And they're going to have a much higher risk of re-intervention and probably don't need the same level of surveillance as the first patient.

and probably need a much higher rate of surveillance. So not only can we have individualized predictors of risk for patients, but this is the regulatory aspect to it as well.

Multiple scenario testing can be undertaken. And these are improved not only with the pre-operative data, but as you've seen with one-year data, and this can tie in with IFU development and also for advising policy such as NICE, which you'll have heard a lot about during the conference.

So this is just one example. If you take a patient with a sixty-five millimeter aneurysm, eighteen millimeter iliac, and the suprarenal angle at sixty degrees. If you breach two or more of these factors in red, we have the pre-operative prediction.

Around 20% of cases will be in the high risk group. The high risk patients have about a 50-55% freedom from device for related problems at five years. And the low risk group, so if you don't breach those groups, 75% chance of freedom from intervention.

In the green, if you then add in a stent at one year, you can see that still around 20% of patients remain in the high risk group. But in the low risk group, you now have 85% of patients won't need a re-intervention at five years,

and less of a movement in the high risk group. So this can clearly inform IFU. And here you see the Kaplan-Meier curves, those same groups based pre-operatively, and at one year. In conclusion, LEAR can provide

a device specific estimation of EVAR outcome out to five years. It can be based on pre-operative variables alone by one year. Duplex surveillance helps predict risk. It's clearly of regulatory interest in the outcomes of EVAR.

And an E-portal is being developed for dissemination. Thank you very much.

- Thank you Professor Veith. Thank you for giving me the opportunity to present on behalf of my chief the results of the IRONGUARD 2 study. A study on the use of the C-Guard mesh covered stent in carotid artery stenting. The IRONGUARD 1 study performed in Italy,

enrolled 200 patients to the technical success of 100%. No major cardiovascular event. Those good results were maintained at one year followup, because we had no major neurologic adverse event, no stent thrombosis, and no external carotid occlusion. This is why we decided to continue to collect data

on this experience on the use of C-Guard stent in a new registry called the IRONGUARD 2. And up to August 2018, we recruited 342 patients in 15 Italian centers. Demographic of patients were a common demographic of at-risk carotid patients.

And 50 out of 342 patients were symptomatic, with 36 carotid with TIA and 14 with minor stroke. Stenosis percentage mean was 84%, and the high-risk carotid plaque composition was observed in 28% of patients, and respectively, the majority of patients presented

this homogenous composition. All aortic arch morphologies were enrolled into the study, as you can see here. And one third of enrolled patients presented significant supra-aortic vessel tortuosity. So this was no commerce registry.

Almost in all cases a transfemoral approach was chosen, while also brachial and transcervical approach were reported. And the Embolic Protection Device was used in 99.7% of patients, with a proximal occlusion device in 50 patients.

Pre-dilatation was used in 89 patients, and looking at results at 24 hours we reported five TIAs and one minor stroke, with a combined incidence rate of 1.75%. We had no myocardial infection, and no death. But we had two external carotid occlusion.

At one month, we had data available on 255 patients, with two additional neurological events, one more TIA and one more minor stroke, but we had no stent thrombosis. At one month, the cumulative results rate were a minor stroke rate of 0.58%,

and the TIA rate of 1.72%, with a cumulative neurological event rate of 2.33%. At one year, results were available on 57 patients, with one new major event, it was a myocardial infarction. And unfortunately, we had two deaths, one from suicide. To conclude, this is an ongoing trial with ongoing analysis,

and so we are still recruiting patients. I want to thank on behalf of my chief all the collaborators of this registry. I want to invite you to join us next May in Rome, thank you.

- Mr. Chairman, ladies and gentlemen, good morning. I'd like to thank Dr. Veith for the opportunity to present at this great meeting. I have nothing to disclose. Since Dr. DeBakey published the first paper 60 years ago, the surgical importance of deep femoral artery has been well investigated and documented.

It can be used as a reliable inflow for low extremity bypass in certain circumstances. To revascularize the disease, the deep femoral artery can improve rest pain, prevent or delay the amputation, and help to heal amputation stump.

So, in this slide, the group patient that they used deep femoral artery as a inflow for infrainguinal bypass. And 10-year limb salvage was achieved in over 90% of patients. So, different techniques and configurations

of deep femoral artery angioplasty have been well described, and we've been using this in a daily basis. So, there's really not much new to discuss about this. Next couple minutes, I'd like to focus on endovascular invention 'cause I lot I think is still unclear.

Dr. Bath did a systemic review, which included 20 articles. Nearly total 900 limbs were treated with balloon angioplasty with or without the stenting. At two years, the primary patency was greater than 70%. And as you can see here, limb salvage at two years, close to, or is over 98% with very low re-intervention rate.

So, those great outcomes was based on combined common femoral and deep femoral intervention. So what about isolated deep femoral artery percutaneous intervention? Does that work or not? So, this study include 15 patient

who were high risk to have open surgery, underwent isolated percutaneous deep femoral artery intervention. As you can see, at three years, limb salvage was greater than 95%. The study also showed isolated percutaneous transluminal

angioplasty of deep femoral artery can convert ischemic rest pain to claudication. It can also help heal the stump wound to prevent hip disarticulation. Here's one of my patient. As you can see, tes-tee-lee-shun with near

or total occlusion of proximal deep femoral artery presented with extreme low-extremity rest pain. We did a balloon angioplasty. And her ABI was increased from 0.8 to 0.53, and rest pain disappeared. Another patient transferred from outside the facility

was not healing stump wound on the left side with significant disease as you can see based on the angiogram. We did a hybrid procedure including stenting of the iliac artery and the open angioplasty of common femoral artery and the profunda femoral artery.

Significantly improved the perfusion to the stump and healed wound. The indications for isolated or combined deep femoral artery revascularization. For those patient presented with disabling claudication or rest pain with a proximal

or treatable deep femoral artery stenosis greater than 50% if their SFA or femoral popliteal artery disease is unsuitable for open or endovascular treatment, they're a high risk for open surgery. And had the previous history of multiple groin exploration, groin wound complications with seroma or a fungal infection

or had a muscle flap coverage, et cetera. And that this patient should go to have intervascular intervention. Or patient had a failed femoral pop or femoral-distal bypass like this patient had, and we should treat this patient.

So in summary, open profundaplasty remains the gold standard treatment. Isolated endovascular deep femoral artery intervention is sufficient for rest pain. May not be good enough for major wound healing, but it will help heal the amputation stump

to prevent hip disarticulation. Thank you for much for your attention.

Disclaimer: Content and materials on Medlantis are provided for educational purposes only, and are intended for use by medical professionals, not to be used self-diagnosis or self-treatment. It is not intended as, nor should it be, a substitute for independent professional medical care. Medical practitioners must make their own independent assessment before suggesting a diagnosis or recommending or instituting a course of treatment. The content and materials on Medlantis should not in any way be seen as a replacement for consultation with colleagues or other sources, or as a substitute for conventional training and study.