Create an account and get 3 free clips per day.
Chapters
Portal Hypertension|Stenting, TIPS|15|Female
Portal Hypertension|Stenting, TIPS|15|Female
2016atresiabeambiliarycatheterconecreatinghemorrhagemesentericopacifiedportalSIRvenous
Use Of Indirect Access Sites For AV Intervention
Use Of Indirect Access Sites For AV Intervention
accessapproacharterialcathetercephalicconvertdiagnosticdirectexposurefemoralferralFistulafistulasimmaturejugularoutflowPartially occluded immature lt upper arm AVFperformedpunctureradiationreportedretrospectiverupturedsnareStaged Trans-jugular approachstenosisstudyTrans-jugular approachtransjugularveinvenous
Tips And Tricks For Thrombo-Embolectomy For Clot Removal From All Arteries Using The Indigo System: How To Measure Success
Tips And Tricks For Thrombo-Embolectomy For Clot Removal From All Arteries Using The Indigo System: How To Measure Success
Aspiration SystemAspiration ThrombectomyCovered stentInjured infa-renal aorta with embolegenic thrombusPenumbraPenumbra’s Indigotherapeutic
Technical Tips For The Management Of Cervical And Mediastinal Iatrogenic Artery Injuries: How To Avoid Disasters
Technical Tips For The Management Of Cervical And Mediastinal Iatrogenic Artery Injuries: How To Avoid Disasters
9F Sheath in Lt SCAAbbottaccessarterybrachialcarotidcatheterCordisDual Access (Rt Femora + SC sheath) ttt with suture mediated proglid over 0.035 inch wireendovascularfemoralfrenchgraftiatrogenicimaginginjuriesleftPer-Close suture mediated ProgliderangingsheathstentsubclaviantreatedvarietyvascularvenousvertebralVessel Closure Devicewire
Surgical vs. Endovascular Management Of Cephalic Arch Syndrome
Surgical vs. Endovascular Management Of Cephalic Arch Syndrome
adjunctsanatomicangioplastyarchballoonballoonsbrachiocephaliccephalicdeploymentfistulasfunctionalgoregraftgraftingInterventionspatencypredictorsprimaryradiocephalicrecurrentstenosesstenosisstentStent graftstentingsuperiorsurgicaltranspositionviabahn
Results Of A Multicenter Italian Registry Of Real World CAS With The C-Guard Mesh Covered Stent: The IRONGUARD 2 Study
Results Of A Multicenter Italian Registry Of Real World CAS With The C-Guard Mesh Covered Stent: The IRONGUARD 2 Study
brachialC-GuardcarotidCASCovered stentcumulativedemographicdeviceembolicembolic protection deviceenrolledexternalInspire MDminormyocardialneurologicneurologicalocclusionongoingpatientsproximalratestenosisstenttiastranscervicaltransfemoral
Challenges And Solutions In Complex Dialysis Access Cases
Challenges And Solutions In Complex Dialysis Access Cases
accessangiogramarteryaxillarybrachialcannulationcathetercentralchallengeschallengingconnecteddissectedextremityFistulaflowfunctioninggoregrafthybridischemiaMorbid Obese/Sub-optimal anatomy / need immediate accessoutflowpatientRt Upper Arm loop AVGsegmentstealStent graftsuboptimaltransplanttunneleduppervascularveinvenous
Inari CloTriever Device For Acute DVT
Inari CloTriever Device For Acute DVT
anteriorbonecatheterclotCloTriever CatheterCloTriever ProcedureCloTriever SheathcompressibleCorpectomy with interbody Cage / Local Bone Graft with Local Bone PowderduplexenrollextravasationfemoralhardwareiliacinsertedLumbar Interbody fusion Via Anteriro approachlyticmaterialobstructedorthopedicoutcomespatientpatientsphasicpoplitealregistrysegmentsheathspondylolisthesisSpondylolisthesis L5-S1 / Post- Operat Acute extensive Lt Lower Limb DVTstentsubclavianswellingtherapythrombectomythrombosedthrombustibialtpaveinvenous
With Complex AAAs, How To Make Decisions Re Fenestrations vs. Branches: Which Bridging Branch Endografts Are Best
With Complex AAAs, How To Make Decisions Re Fenestrations vs. Branches: Which Bridging Branch Endografts Are Best
anatomicanatomyaneurysmaneurysmsaorticarteriesballoonBARDBEVARbranchbranchedbranchesceliaccenterscombinationCoveracovereddeviceendovascularexpandableextremityfenestratedFenestrated EndograftfenestrationfenestrationsFEVARincidencemayoocclusionocclusionsphenotypeproximalproximallyrenalrenal arteriesrenalsreproduciblestentstentstechnicaltherapeutictortuositytypeversusViabah (Gore) / VBX (Gore) / Bentely (Bentely)visceral
Single Session Continuous Aspiration Thrombectomy (SSCAT) For All DVT Utilizing Indigo Thrombectomy System
Single Session Continuous Aspiration Thrombectomy (SSCAT) For All DVT Utilizing Indigo Thrombectomy System
Angiojet Power Plus CatheterantegradeaspirationcatheterdaviesdeviceFinal Indigo + Lytics + Wall Stent +Indigo Aspiration System Devices (Pneumbra)Lt Ilio-Femoral DVTlyticsmaximaloccludedPower Pulse Spray Techniquethrombectomyunderlyingutilizedvenous
Comparative Cost Effectiveness Of DCBs vs. DESs Favor DESs
Comparative Cost Effectiveness Of DCBs vs. DESs Favor DESs
additionalangioplastybailoutballoonballoonsbasedcentercodescostDCBdecreasedDESdollarsgeometricInterventionslimbmedicalmedicareoutpatientpasspatencyPatentpayerpercentprimaryreimbursementreinterventionreinterventionsrevascularizationstents
How To Treat By EVAR Complex Aorto-Iliac AAAs In Patients With Renal Transplants, Horseshoe Or Pelvic Kidneys: Technical Tips
How To Treat By EVAR Complex Aorto-Iliac AAAs In Patients With Renal Transplants, Horseshoe Or Pelvic Kidneys: Technical Tips
accessoryaneurysmalaneurysmsantegradeaorticapproacharteriesarteryatypicalbifurcationbypasscontralateraldistalembolizationendoendograftingendovascularevarfairlyfemoralfenestratedflowfollowuphybridhypogastriciliacincisionmaintainmaneuversmultipleocclusiveOpen Hybridoptionspatientspelvicreconstructionreconstructionsreinterventionsrenalrenal arteryrenalsrepairsurvival
What Morphological Changes On CT After EVAR Predict The Need For Re-Interventions: From The DREAM Trial
What Morphological Changes On CT After EVAR Predict The Need For Re-Interventions: From The DREAM Trial
analysisaneurysmangulationaorticdiameterendograftendoleakendoleaksendovascularevariliaclengthlimbmaximalneckpatientspredictpredictivepredictspreoperativeproximalreinterventionsscanssecondaryshrinkagestenosisstenttherapeuticthrombus
New Devices For False Lumen Obliteration With TBADs: Indications And Results
New Devices For False Lumen Obliteration With TBADs: Indications And Results
aneurysmangiographyaortaballooningCcentimeterdilatorendograftendovascularEndovascular DevicefenestratedgraftiliacimplantedlumenoccludeoccluderoccludersoccludesremodelingstentStent graftstentstechniqueTEVARtherapeuticthoracicthoracoabdominalVeithy-plugyplug
Value Of Parallel Grafts To Treat Chronic TBADs With Extensive TAAAs: Technical Tips And Results
Value Of Parallel Grafts To Treat Chronic TBADs With Extensive TAAAs: Technical Tips And Results
GORE MedicalGORE VIABAHNL EIA-IIA bypassleft carotid subclavian bypassstent graft systemTBAD with TAAAtherapeutic
Is Drug Neuroprotection After Thrombectomy For Acute Stroke Or Other Ischemic Cerebral Insults Feasible: Future Prospects
Is Drug Neuroprotection After Thrombectomy For Acute Stroke Or Other Ischemic Cerebral Insults Feasible: Future Prospects
acuteadvanceanteriorcarotidcerebralcollateralsdeliveryintracranialmechanicalneuroprotection agentsneuroprotectiveofferedpatientpatientsPenumbrapotentpreservestrokethrombectomyThromectomytpatreat
Why Open Endarterectomy Is The Best Treatment For Common Femoral Artery Lesions: It Is Still The Gold Standard In Most Cases Despite What You May Read And Hear
Why Open Endarterectomy Is The Best Treatment For Common Femoral Artery Lesions: It Is Still The Gold Standard In Most Cases Despite What You May Read And Hear
amputationarterycommoncommon femoralembolizationendarterectomyendovascularfemoralfemoral arteryhematomaInterventionsmehtamorbiditymortalitypatencypatientsperioperativeprimaryrestenosisrevascularizationrotationalstentstentingstentssuperficialsurgicalsurvivalTECCO
How To Treat Labial Varices: Sclerotherapy, USG Sclerotherapy And Or Phlebectomy
How To Treat Labial Varices: Sclerotherapy, USG Sclerotherapy And Or Phlebectomy
anesthesiaanteriorcomplaintsdyspareuniahemorrhageiliacincisionincludelabialLabial Varices + Leg VVligationLocal SclerotherapymalformationpatientpelvicperforatorsperformedphlebectomypolidocanolposteriorpostpartumrefluxrefluxingsaphenofemoralsclerosclerotherapysulfatesuperficialsymptomaticsymptomstetradecylultrasoundvaricositiesveinsVeithvenogramvenousversusvulvar
Treating Venous Thromboembolism Without Lytic Medications
Treating Venous Thromboembolism Without Lytic Medications
amountaspirateaspirationassistedcatheterclotcreatedevicedevicesfocalfrenchiliacmechanicalpatientpulmonaryrheolyticstentsuctionthrombustypetypesvacuumveinvenous
Update On The Advantages, Limitations And Midterm Results With The Terumo Aortic 3 Branch Arch Device: What Lesions Can It Treat
Update On The Advantages, Limitations And Midterm Results With The Terumo Aortic 3 Branch Arch Device: What Lesions Can It Treat
4 branch CMD TAAA deviceacuteAscending Graft Replacementcardiac arrestRelayBranchRepair segment with CMD Cuffruptured type A dissection w/ tamponadestent graft systemTerumo Aortictherapeutic
Advantages Of Cook Zenith Spiral Z Limbs For EVARs Landing In The External Iliac Artery
Advantages Of Cook Zenith Spiral Z Limbs For EVARs Landing In The External Iliac Artery
aneurysmarterybuttockclaudicationCook ZenithdeployedendograftendoleaksevarevarsexcellentfinalgrafthelicalhypogastriciliacjapaneselandinglimbobservationalocclusionoperativepatencypatientspercentrenalrequiredspiralSpiral Z graftstenosisstentStent graftstentsstudytripleVeithzenith
Octopus Technique To Treat Urgent Or Ruptured TAAAs With OTS Components: What Is It, Technical Tips And Results
Octopus Technique To Treat Urgent Or Ruptured TAAAs With OTS Components: What Is It, Technical Tips And Results
6.8 cm TAAAGORE MedicalGore Viabahn VBXOctopus Endovascular Techniquestent graft systemtherapeuticviabahn
How Best To Treat Pediatric Vascular Injuries
How Best To Treat Pediatric Vascular Injuries
adjunctsangiographyarterialaxialbismuthbluntbrachialcannulationcenterschildrencommoncontralateralendovascularextremityiatrogenicinjuriesinjuryinterpositionischemiclimbmechanismminimalmortalitypediatricpenetratingradialrepairrepairedsaphenoussinghstentsuturestraumatruncaltypevascularVeithversus
Surgical Creation Of A Moncusp Valve
Surgical Creation Of A Moncusp Valve
applycompetingcontralateraldeependovascularfibroticflapflowhemodynamicmalfunctioningmobilemodelingMono-cuspid neovalveMono-cuspid Stent PrototypeparietalreconstructionrefluxstentthrombosisvalveValvuloplastyveinvenouswall
Estimation Of Long-Term Aortic Risk After EVAR: The LEAR Model: How Can It Guide And Modulate Surveillance Protocols
Estimation Of Long-Term Aortic Risk After EVAR: The LEAR Model: How Can It Guide And Modulate Surveillance Protocols
aneurysmaorticcentimeterdeviceendoleaksevarlearlowoutcomespatientpatientspredictorsregulatoryriskshrinkagestentsuprarenalSurveillanceVeith
Update On The everlinQ Percutaneous Fistula Device
Update On The everlinQ Percutaneous Fistula Device
adequatearterialarteryAVFbasicallybasilicbrachialcannulatedcathetercatheterscephaliccomponentcreatecreatescreatingdeviceEverlinQFistulafistulasflowfunctioningInterventionsmagnetsmatureoptionpatientsperforatorprimaryradiocephalicsuperficialtrialulnarveinveinsvenousWavelinq 6F EndoAVF System
Italian National Registry Results With Inner Branch Devices For Aortic Arch Disease
Italian National Registry Results With Inner Branch Devices For Aortic Arch Disease
aortaaorticarcharteriesarteryascendingavailabilitybarbsbranchcarotidcatheterizedcommondecreasedevicesdissectiondoublr branch stent graftendoleakendovascularevarexcludinggraftguptalimbmajormidtermmorphologicalmortalityoperativepatientpatientsperioperativeproximalregistryrepairretrogradestentStent graftstentingstrokesupraterumotherapeutictibialvascular
Transcript

This was a 15 year old patient. Status, post liver transplant at the age of 15 months for biliary atresia She was diagnosed with Portal hypertension and presented with recurrent upper GI bleed.

So again we decided that's it's time for the TIFF/g procedure. Here you can see the CO2 port gram. Their is nothing going in the portal system and this before [INAUDIBLE] again the same thing, we did the cone beam CT. First thing that we did was that we also went from the femoral approach

going into the SMA and opacifying all these collaterals. So you can see the clot and the portal system, all these opacified collaterals. This is the catheter coming through the aorta. And again using the same software we can delineate your hepatic

vein site and the portal venous collaterals. And it helps again to define your trajectory that where exactly you want to land when you're creating this shunt. And And all this that you're seeing [UNKNOWN] overlay the one major advantage is that any time you are rotating your eye you're creating

different angles. This relationship does not change. So that gives you comfort. And having done the cone beam CT at that same time you know that there is no other bowel loop, or anything that could potentially

cause a problem. So it certainly helps to move forward. So using this eye guide, then again we created this tract, and after this we got into the mesenteric circulation here, and placed two

of the graphs. And this patient I've followed for about a year or so and she did fine and here'e the catheter in the SME and this was the post tips the we did this. Another advantage of having these tools as you can do CT scan right away pretty much see if there's anything bad has happened or not,

obviously patients stay [UNKNOWN] stable. So we didn't see any extra hemorrhage so we were pretty happy about that,

- I'm going to be speaking about indirect access sites for access intervention. I'm going to be focusing on the transjugular approach. So access interventions, typically we perform them through a direct puncture of the fistula. Sometimes you place two introducers. There are some disadvantages to the direct approach.

The crossing catheters technique that we generally use for declots is awkward and cumbersome. The introducers can obstruct flow, there's dead space behind the introducers that can trap clot, and there's radiation exposure or the direct exposure

or scatter radiation from hands near the field. Admit it, we've all had access-site complications, suture-site necrosis and infection, as well as pseudoaneurysms. There's also prolonged procedure time related to needing to obtain hemostasis

in the high-pressure segment. There are also problems particularly to immature fistulas, such as hematoma formation, spasm at the introducer site causing pseudo-stenosis, decreased flow, and fistula thrombosis. Now, the good news is that we do have options

for alternative access sites. I'm sure many of you here use arterial access for immature fistulas in particular. Brachial access can be used to, this can be used for diagnostic or therapeutic purposes. We can also utilize radial or ulnar access.

Rarely, femoral access is used, as we saw in the last presentation. But there's also pendula venous access sites. You can sometimes, as a fortuitous tributary, what I call a target of opportunity, and also, the internal jugular vein.

Now, the transjugular approach was first reported in 1998. It does have some definite advantages over direct puncture technique. You can avoid the cumbersome access, you can keep your hands away from the beam, and there's no dead space as compared

to crossing sheaths for your declot. And if the intervention is unsuccessful, you can convert your IJ access to a catheter if you already have a wire in it. There are some technical challenges associated with this technique.

You do have to overcome the valves. It can be difficult to access the cephalic vein, but you can get around this by using a snare. And there's possibly a risk of IJ thrombosis if you're using large introducers. When to use this technique?

Well, when direct puncture's going to be difficult or cumbersome, when there's a short cannulation segment, when it's an extensively stented access, and when there's inflow pathology requiring a retrograde approach or arterial empathalogy, and it's a good option for clotted access.

The technique, micropuncture access of the jugular vein, ipsilateral or contralateral, place a sheath, and an important thing to use is a reverse-curve catheter, followed by glidewire. So here, we've cannulated the jugular vein going down,

glidewire out into the arm. If you're unable to cross into the cephalic vein, you can use that snare technique. And you can get a long, stable access in this way. It's been reported about, there's about 10 publications on transjugular approach, seven retrospective studies.

There's a large study that's reported thrombectomy. Also a large study looking at immature fistulas. Smaller studies looking at dysfunctional access and pseudoaneurysms. Two case reports, one review article, but there's of course no randomized studies.

There's a recent study from this year from Ferral and Alonzo. This was a retrospective study. Over two years they performed 30 transjugular AV access interventions. This accounted for 5% of their access experience

and this series was all fistulance. Indications for the procedure, 43% were declots, 43% were arterial and fistual pathology, there were two immature fistulas and two bleeding pseudoaneurysms. The access approach was 29 for ipsilateral,

only one contralateral. The results, 97% technical success, a snare was required in 4 cases, a catheter was inserted in two of the cases. There were no episodes of jugular vein thrombosis. In the remaining time, I'd like to show

a couple of case studies. Again, from Ferral and Alonzo. This is a case of an immature fistula. This was a partially occluded, immature left upper arm fistula. The initial fistulagram shows outflow stenosis

with a multiple stenosis in thrombus, and there's an arterial in stenosis that's distal to the access point, so you're not going to be able to treat that. They performed four millimeter angioplasty. Follow-up fistulagram shows a small, but patent vein

and the arterial end could not be treated. They brought the patient back in two weeks for a staged transjugular approach. And you can see the jugular catheter coming down. The vein diameter's improved, but there's still the untreated arterial end stenosis,

which is easily treated through the jugular approach. This is a study from, a case from Dr. Rabellino, ruptured pseudoaneurysm. This is a basilic transposition with a ruptured pseudoaneurysm at an infiltration site. Pretty ugly arm, swollen, skin necrosis.

I don't think we want to be sticking that arm. They initially went with a femoral approach for the fistulagram, demonstrated the pseudoaneurysm. As you can see here, tandem outflow stenoses. Coming up from below with the femoral artery diagnostic catheter.

Down and into the arm through the jugular approach. And here, you can see the venous outflow after angioplasty, covered stent deployed through the jugular access. So in summary, the transjugular approach is a useful but underutilized technique. The advantages include single-puncture intervention,

does not involve the outflow vein directly, simplified hemostasis, it's a low pressure system. It does have the advantage that you can use large introducers, there's less radiation for the operator, and you can convert to a catheter easily if needed. It is a useful technique for fistula maturation,

thrombectomy, and access maintenance. I say go for the jugular.

- Thank you, it's a pleasure to be here. I'll address how the Indigo Thrombectomy technology can expand the reach of what you can do for your patients. It will preserve treatment options, improve patient outcomes, conserve hospital resources,

and perhaps most importantly, improve your day. The old treatment strategy, every time I had someone with acute limb ischemia I felt like I was shopping at this store. When I went to surgery, I wished I could put a drip catheter in, it lasts a little longer,

to mop up some di when I went to the angio suite, I wished I could cut down and remove some more macroscopic debris. I submit that the new Indigo technology

will provide a new strategy for treating acute arterial ischemia. On the same concepts are predicated STEMI, code stroke, Level I trauma alerts, we've instituted acute aorta, and piggybacked on that, an acute arterial ischemia protocol.

So that means when a patient like this presents with acute arterial ischemia, they get an algorithmic, systemic, trained, metered approach. They go past the holding room directly to the endovascular suite,

and all the processes happen in parallel, not in series. The call team is trained and dedicated, and while anesthesia is working up top with labs and lines, we use the duplex ultrasound to pick carefully our access sites. A faster time to reperfusion allows us to

do it and avoid general anesthesia, incision in hostile groins, and the exposure of lytic therapy, resulting in a decreased morbidity and mortality. Being able to treat the full spectrum of the arterial tree allows us to run options.

We preserve options by first mopping up more proximal clot, and then dripping distally when we need to, or, dripping distally to open up distal targets for surgical bypasses. As an example, this was a recent case

on a trauma CT scan, injured inthrelane aorta with emblogenic thrombus confirmed on intravascular ultrasound. We went in with a large bore system, a cath to aspirate the clot, and then used a cover stent to repair the aorta.

We shot an arteriogram the lower extremities, noticed that it embolized distally, and we used a Cat 6 to pluck out this clot and restore flow. Able to work up and down the full arterial tree. A learning curve for me was to understand that debris has to be corked to removal, which means no flow.

And most other worlds in vascular surgery, flow is good. No flow is bad. Also, you have to vacuum the clot out. Which means you have to uncross the lesion, which is counter intuitive for most of the precepts I've learned.

I've learned to use long sheaths to approach the lesion and to use larger catheters to remove more macroscopic debris. I rarely use the separator, I engage it and cork it for 90 seconds. That allows it to get a firm grip and purchase on it.

And I have to remember that no flow is good. This demonstrates how you approach the catheter with a large sheath. Under roadmap guidance you turn the aspiration vacuum on immediately before you cork it to minimize blood loss. And you use it like a vacuum by uncrossing the lesion

and let it slowly engage and aspirate the catheter. Ninety seconds allows it to get a firm grip and purchase so you can extract it without breaking it loose. I rarely use a separator, I use it only for large thrombus burdens, sub-acute clot, adherent debris,

or when the Indigo catheter is clogged. I strip out the catheter with the separator like a pipe cleaner, and then, every once in a while, on a subacute clot, I'll peck and morcellate it with a separator. Typically, in my lab, when I have new technology

I never have the team trained when I have just the right case, so I've learned over time, to train the team first. And with a trained team, they've taught me a lot. I've found with the Indigo catheter it's hard for me to watch the monitor,

work the catheter, handle the on-off switch, and watch the flow in the canister. So, what we do is we have a spotter who's not scrubbed. They taught me to take the on-off switch out, and then mechanically kink the tubing to make and on-off switch.

And they provide me feedback and just say fast, slow, or corked, so I can run the catheter and watch the monitor. I've learned to beware of the Cook Flexor sheaths, because they scuff up the tip. Use a check flow valve that unscrews from the

catheter if possible. I use coaxial catheters whenever possible, and I telescope them. You can telescope large catheters over small catheters. I use large sheaths and catheters whenever possible, using the preclose technique,

and then you can preserve options if you want to press more distally, you can cinch down, remove the large sheath, put in a 4 5 French, and then press ahead. I also, after I use a pulse technique, will occasionally use the Jungle Juice.

The team taught me the Jungle Juice is half strength contrast, some TPA and some nitroglycerine. When I lace the clot with Jungle Juice, I can observe fluoroscopically, the progress I'm making as I'm aspirating the clot. Thank you.

- These are my disclosures. So central venous access is frequently employed throughout the world for a variety of purposes. These catheters range anywhere between seven and 11 French sheaths. And it's recognized, even in the best case scenario, that there are iatrogenic arterial injuries

that can occur, ranging between three to 5%. And even a smaller proportion of patients will present after complications from access with either a pseudoaneurysm, fistula formation, dissection, or distal embolization. In thinking about these, as you see these as consultations

on your service, our thoughts are to think about it in four primary things. Number one is the anatomic location, and I think imaging is very helpful. This is a vas cath in the carotid artery. The second is th

how long the device has been dwelling in the carotid or the subclavian circulation. Assessment for thrombus around the catheter, and then obviously the size of the hole and the size of the catheter.

Several years ago we undertook a retrospective review and looked at this, and we looked at all carotid, subclavian, and innominate iatrogenic injuries, and we excluded all the injuries that were treated, that were manifest early and treated with just manual compression.

It's a small cohort of patients, we had 12 cases. Eight were treated with a variety of endovascular techniques and four were treated with open surgery. So, to illustrate our approach, I thought what I would do is just show you four cases on how we treated some of these types of problems.

The first one is a 75 year-old gentleman who's three days status post a coronary bypass graft with a LIMA graft to his LAD. He had a cordis catheter in his chest on the left side, which was discovered to be in the left subclavian artery as opposed to the vein.

So this nine French sheath, this is the imaging showing where the entry site is, just underneath the clavicle. You can see the vertebral and the IMA are both patent. And this is an angiogram from a catheter with which was placed in the femoral artery at the time that we were going to take care of this

with a four French catheter. For this case, we had duel access, so we had access from the groin with a sheath and a wire in place in case we needed to treat this from below. Then from above, we rewired the cordis catheter,

placed a suture-mediated closure device, sutured it down, left the wire in place, and shot this angiogram, which you can see very clearly has now taken care of the bleeding site. There's some pinching here after the wire was removed,

this abated without any difficulty. Second case is a 26 year-old woman with a diagnosis of vascular EDS. She presented to the operating room for a small bowel obstruction. Anesthesia has tried to attempt to put a central venous

catheter access in there. There unfortunately was an injury to the right subclavian vein. After she recovered from her operation, on cross sectional imaging you can see that she has this large pseudoaneurysm

coming from the subclavian artery on this axial cut and also on the sagittal view. Because she's a vascular EDS patient, we did this open brachial approach. We placed a stent graft across the area of injury to exclude the aneurism.

And you can see that there's still some filling in this region here. And it appeared to be coming from the internal mammary artery. We gave her a few days, it still was patent. Cross-sectional imaging confirmed this,

and so this was eventually treated with thoracoscopic clipping and resolved flow into the aneurism. The next case is a little bit more complicated. This is an 80 year-old woman with polycythemia vera who had a plasmapheresis catheter,

nine French sheath placed on the left subclavian artery which was diagnosed five days post procedure when she presented with a posterior circulation stroke. As you can see on the imaging, her vertebral's open, her mammary's open, she has this catheter in the significant clot

in this region. To manage this, again, we did duel access. So right femoral approach, left brachial approach. We placed the filter element in the vertebral artery. Balloon occlusion of the subclavian, and then a stent graft coverage of the area

and took the plasmapheresis catheter out and then suction embolectomy. And then the last case is a 47 year-old woman who had an attempted right subclavian vein access and it was known that she had a pulsatile mass in the supraclavicular fossa.

Was noted to have a 3cm subclavian artery pseudoaneurysm. Very broad base, short neck, and we elected to treat this with open surgical technique. So I think as you see these consults, the things to factor in to your management decision are: number one, the location.

Number two, the complication of whether it's thrombus, pseudoaneurysm, or fistula. It's very important to identify whether there is pericatheter thrombus. There's a variety of techniques available for treatment, ranging from manual compression,

endovascular techniques, and open repair. I think the primary point here is the prevention with ultrasound guidance is very important when placing these catheters. Thank you. (clapping)

- So I'd like to thank Dr. Ascher, Dr. Sidawy, Dr. Veith, and the organizers for allowing us to present some data. We have no disclosures. The cephalic arch is defined as two centimeters from the confluence of the cephalic vein to either the auxiliary/subclavian vein. Stenosis in this area occurs about 39%

in brachiocephalic fistulas and about 2% in radiocephalic fistulas. Several pre-existing diseases can lead to the stenosis. High flows have been documented to lead to the stenosis. Acute angles. And also there is a valve within the area.

They're generally short, focal in nature, and they're associated with a high rate of thrombosis after intervention. They have been associated with turbulent flow. Associated with pre-existing thickening.

If you do anatomic analysis, about 20% of all the cephalic veins will have that. This tight anatomical angle linked to the muscle that surrounds it associated with this one particular peculiar valve, about three millimeters from the confluence.

And it's interesting, it's common in non-diabetics. Predictors if you are looking for it, other than ultrasound which may not find it, is calcium-phosphate product, platelet count that's high, and access flow.

If one looks at interventions that have commonly been reported, one will find that both angioplasty and stenting of this area has a relatively low primary patency with no really discrimination between using just the balloon or stent.

The cumulative patency is higher, but really again, deployment of an angioplasty balloon or deployment of a stent makes really no significant difference. This has been associated with residual stenosis

greater than 30% as one reason it fails, and also the presence of diabetes. And so there is this sort of conundrum where it's present in more non-diabetics, but yet diabetics have more of a problem. This has led to people looking to other alternatives,

including stent grafts. And in this particular paper, they did not look at primary stent grafting for a cephalic arch stenosis, but mainly treating the recurrent stenosis. And you can see clearly that the top line in the graph,

the stent graft has a superior outcome. And this is from their paper, showing as all good paper figures should show, a perfect outcome for the intervention. Another paper looked at a randomized trial in this area and also found that stent grafts,

at least in the short period of time, just given the numbers at risk in this study, which was out after months, also had a significant change in the patency. And in their own words, they changed their practice and now stent graft

rather than use either angioplasty or bare-metal stents. I will tell you that cutting balloons have been used. And I will tell you that drug-eluting balloons have been used. The data is too small and inconclusive to make a difference. We chose a different view.

We asked a simple question. Whether or not these stenoses could be best treated with angioplasty, bare-metal stenting, or two other adjuncts that are certainly related, which is either a transposition or a bypass.

And what we found is that the surgical results definitely give greater long-term patency and greater functional results. And you can see that whether you choose either a transposition or a bypass, you will get superior primary results.

And you will also get superior secondary results. And this is gladly also associated with less recurrent interventions in the ongoing period. So in conclusion, cephalic arch remains a significant cause of brachiocephalic AV malfunction.

Angioplasty, across the literature, has poor outcomes. Stent grafting offers the best outcomes rather than bare-metal stenting. We have insufficient data with other modalities, drug-eluting stents, drug-eluting balloons,

cutting balloons. In the correct patient, surgical options will offer superior long-term results and functional results. And thus, in the good, well-selected patient, surgical interventions should be considered

earlier in this treatment rather than moving ahead with angioplasty stent and then stent graft. Thank you so much.

- Thank you Professor Veith. Thank you for giving me the opportunity to present on behalf of my chief the results of the IRONGUARD 2 study. A study on the use of the C-Guard mesh covered stent in carotid artery stenting. The IRONGUARD 1 study performed in Italy,

enrolled 200 patients to the technical success of 100%. No major cardiovascular event. Those good results were maintained at one year followup, because we had no major neurologic adverse event, no stent thrombosis, and no external carotid occlusion. This is why we decided to continue to collect data

on this experience on the use of C-Guard stent in a new registry called the IRONGUARD 2. And up to August 2018, we recruited 342 patients in 15 Italian centers. Demographic of patients were a common demographic of at-risk carotid patients.

And 50 out of 342 patients were symptomatic, with 36 carotid with TIA and 14 with minor stroke. Stenosis percentage mean was 84%, and the high-risk carotid plaque composition was observed in 28% of patients, and respectively, the majority of patients presented

this homogenous composition. All aortic arch morphologies were enrolled into the study, as you can see here. And one third of enrolled patients presented significant supra-aortic vessel tortuosity. So this was no commerce registry.

Almost in all cases a transfemoral approach was chosen, while also brachial and transcervical approach were reported. And the Embolic Protection Device was used in 99.7% of patients, with a proximal occlusion device in 50 patients.

Pre-dilatation was used in 89 patients, and looking at results at 24 hours we reported five TIAs and one minor stroke, with a combined incidence rate of 1.75%. We had no myocardial infection, and no death. But we had two external carotid occlusion.

At one month, we had data available on 255 patients, with two additional neurological events, one more TIA and one more minor stroke, but we had no stent thrombosis. At one month, the cumulative results rate were a minor stroke rate of 0.58%,

and the TIA rate of 1.72%, with a cumulative neurological event rate of 2.33%. At one year, results were available on 57 patients, with one new major event, it was a myocardial infarction. And unfortunately, we had two deaths, one from suicide. To conclude, this is an ongoing trial with ongoing analysis,

and so we are still recruiting patients. I want to thank on behalf of my chief all the collaborators of this registry. I want to invite you to join us next May in Rome, thank you.

- I think by definition this whole session today has been about challenging vascular access cases. Here's my disclosures. I went into vascular surgery, I think I made the decision when I was either a fourth year medical student or early on in internship because

what intrigued me the most was that it seemed like vascular surgeons were only limited by their imagination in what we could do to help our patients and I think these access challenges are perfect examples of this. There's going to be a couple talks coming up

about central vein occlusion so I won't be really touching on that. I just have a couple of examples of what I consider challenging cases. So where do the challenges exist? Well, first, in creating an access,

we may have a challenge in trying to figure out what's going to be the best new access for a patient who's not ever had one. Then we are frequently faced with challenges of re-establishing an AV fistula or an AV graft for a patient.

This may be for someone who's had a complication requiring removal of their access, or the patient who was fortunate to get a transplant but then ended up with a transplant rejection and now you need to re-establish access. There's definitely a lot of clinical challenges

maintaining access: Treating anastomotic lesions, cannulation zone lesions, and venous outflow pathology. And we just heard a nice presentation about some of the complications of bleeding, infection, and ischemia. So I'll just start with a case of a patient

who needed to establish access. So this is a 37-year-old African-American female. She's got oxygen-dependent COPD and she's still smoking. Her BMI is 37, she's left handed, she has diabetes, and she has lupus. Her access to date - now she's been on hemodialysis

for six months, all through multiple tunneled catheters that have been repeatedly having to be removed for infection and she was actually transferred from one of our more rural hospitals into town because she had a infected tunneled dialysis catheter in her femoral region.

She had been deemed a very poor candidate for an AV fistula or AV graft because of small veins. So the challenges - she is morbidly obese, she needs immediate access, and she has suboptimal anatomy. So our plan, again, she's left handed. We decided to do a right upper extremity graft

but the plan was to first explore her axillary vein and do a venogram. So in doing that, we explored her axillary vein, did a venogram, and you can see she's got fairly extensive central vein disease already. Now, she had had multiple catheters.

So this is a venogram through a 5-French sheath in the brachial vein in the axilla, showing a diffusely diseased central vein. So at this point, the decision was made to go ahead and angioplasty the vein with a 9-millimeter balloon through a 9-French sheath.

And we got a pretty reasonable result to create venous outflow for our planned graft. You can see in the image there, for my venous outflow I've placed a Gore Hybrid graft and extended that with a Viabahn to help support the central vein disease. And now to try and get rid of her catheters,

we went ahead and did a tapered 4-7 Acuseal graft connected to the brachial artery in the axilla. And we chose the taper mostly because, as you can see, she has a pretty small high brachial artery in her axilla. And then we connected the Acuseal graft to the other end of the Gore Hybrid graft,

so at least in the cannulation zone we have an immediate cannualation graft. And this is the venous limb of the graft connected into the Gore hybrid graft, which then communicates directly into the axillary vein and brachiocephalic vein.

So we were able to establish a graft for this patient that could be used immediately, get rid of her tunneled catheter. Again, the challenges were she's morbidly obese, she needs immediate access, and she has suboptimal anatomy, and the solution was a right upper arm loop AV graft

with an early cannulation segment to immediately get rid of her tunneled catheter. Then we used the Gore Hybrid graft with the 9-millimeter nitinol-reinforced segment to help deal with the preexisting venous outflow disease that she had, and we were able to keep this patient

free of a catheter with a functioning access for about 13 months. So here's another case. This is in a steal patient, so I think it's incredibly important that every patient that presents with access-induced ischemia to have a complete angiogram

of the extremity to make sure they don't have occult inflow disease, which we occasionally see. So this patient had a functioning upper arm graft and developed pretty severe ischemic pain in her hand. So you can see, here's the graft, venous outflow, and she actually has,

for the steal patients we see, she actually had pretty decent flow down her brachial artery and radial and ulnar artery even into the hand, even with the graft patent, which is usually not the case. In fact, we really challenged the diagnosis of ischemia for quite some time, but the pressures that she had,

her digital-brachial index was less than 0.5. So we went ahead and did a drill. We've tried to eliminate the morbidity of the drill bit - so we now do 100% of our drills when we're going to use saphenous vein with endoscopic vein harvest, which it's basically an outpatient procedure now,

and we've had very good success. And here you can see the completion angiogram and just the difference in her hand perfusion. And then the final case, this is a patient that got an AV graft created at the access center by an interventional nephrologist,

and in the ensuing seven months was treated seven different times for problems, showed up at my office with a cold blue hand. When we duplexed her, we couldn't see any flow beyond the AV graft anastomosis. So I chose to do a transfemoral arteriogram

and what you can see here, she's got a completely dissected subclavian axillary artery, and this goes all the way into her arterial anastomosis. So this is all completely dissected from one of her interventions at the access center. And this is the kind of case that reminded me

of one of my mentors, Roger Gregory. He used to say, "I don't wan "I just want out of the trap." So what we ended up doing was, I actually couldn't get into the true lumen from antegrade, so I retrograde accessed

her brachial artery and was able to just re-establish flow all the way down. I ended up intentionally covering the entry into her AV graft to get that out of the circuit and just recover her hand, and she's actually been catheter-dependent ever since

because she really didn't want to take any more chances. Thank you very much.

- Thank you very much, so my disclosures, I'm one of the co-PIs for national registry for ANARI. And clearly venous clot is different, requires different solutions for the arterial system. So this is a device that was built ground up to work in the venous system. And here's a case presentation of a 53 year old male,

with a history of spondylolisthesis had a lumbar inner body fusion, he had an anterior approach and corpectomy with application of an inner body cage. And you can see these devices here. And notably he had application of local bone graft and bone powder

and this is part of what happened to this patient. About seven days later he came in with significant left leg swelling and venous duplex showed clot right here, and this extended all the way down to the tibial vessels. And if you look at the CT

you can see extravasation of that bone powder and material obstructing the left iliac vein. And had severe leg swelling so the orthopedic people didn't want us to use TPA in this patient so we considered a mechanical solution. And so at this day and age I think goals of intervention

should be to maximize clot removal of course and minimize bleeding risk and reduce the treatment or infusion time and go to single session therapy whenever possible. Our ICUs are full all the time and so putting a lytic patient in there

reduces our ability to get other patients in. (mouse clicks So this is the ClotTriever thrombectomy device. It has a sheath that is a 13 French sheath and they're developing a 16 French, that opens up with a funnel

after it's inserted into the poplitiel. So the funnel is in the lower femoral vein and this helps funnel clot in when it's pulled down. The catheter has this coring element that abuts the vein wall and carves the thrombus off in a collecting bag

that extends up above to allow the thrombus to go into the bag as you pull it down. So you access the popliteal vein, cross the thrombosed segments with standard techniques and you need to then put an exchange length wire up into the SVC

or even out into the subclavian vein for stability. And then the catheter's inserted above the clot and is gradually pulled down, sort of milking that stuff off of the wall and into the bag that is then taken down to the funnel and out of the leg.

So this is the patient we had, we had thrombus in the femoral and up into the IVC. Extensive, you can see the hardware here. And it was very obstructed right at that segment where it was, had the bone material pushing on the vein it was quite difficult to get through there

but finally we did and we ballooned that to open a channel up large enough to accommodate ClotTriever catheter. We then did multiple passes and we extracted a large amount of thrombus. Some looking like typically acute stuff

and then some more dense material that may have been a few days worth of build up on the wall there. We then stinted with an 18 by 90 across the obstructed segment and this was our completion run.

It's not perfect but it looks like a pretty good channel going through. This is the hardware not obstruction at that level. Hospital course, the patient had significant improvement in their swelling by post-op day one. Was discharged on compression and anti-coagulation.

He returned about two months ago for his three month follow-up and really had very minimal symptoms in the left leg. Venous duplex showed that the left common femoral was partially compressible but did have phasic flow and the stent appeared to be open through it's course.

So of course this is an anecdote, this is early in the experience with this catheter. There have been numerous improvements made to ease the use of it and do it in fewer steps. And so we're starting a ClotTriever outcomes registry

to enroll up to 500 patients to begin to define outcomes with this device. It does offer the promise of single session therapy without lytic administration and we'll see how it performs and which patients it works best in through the registry.

Thank you very much.

- Thank you and thanks again Frank for the kind invitation to be here another year. So there's several anatomic considerations for complex aortic repair. I wanted to choose between fenestrations or branches,

both with regards to that phenotype and the mating stent and we'll go into those. There are limitations to total endovascular approaches such as visceral anatomy, severe angulations,

and renal issues, as well as shaggy aortas where endo solutions are less favorable. This paper out of the Mayo Clinic showing that about 20% of the cases of thoracodynia aneurysms

non-suitable due to renal issues alone, and if we look at the subset that are then suitable, the anatomy of the renal arteries in this case obviously differs so they might be more or less suitable for branches

versus fenestration and the aneurysm extent proximally impacts that renal angle. So when do we use branches and when do we use fenestrations? Well, overall, it seems to be, to most people,

that branches are easier to use. They're easier to orient. There's more room for error. There's much more branch overlap securing those mating stents. But a branch device does require

more aortic coverage than a fenestrated equivalent. So if we extrapolate that to juxtarenal or pararenal repair a branched device will allow for much more proximal coverage

than in a fenestrated device which has, in this series from Dr. Chuter's group, shows that there is significant incidence of lower extremity weakness if you use an all-branch approach. And this was, of course, not biased

due to Crawford extent because the graft always looks the same. So does a target vessel anatomy and branch phenotype matter in of itself? Well of course, as we've discussed, the different anatomic situations

impact which type of branch or fenestration you use. Again going back to Tim Chuter's paper, and Tim who only used branches for all of the anatomical situations, there was a significant incidence of renal branch occlusion

during follow up in these cases. And this has been reproduced. This is from the Munster group showing that tortuosity is a significant factor, a predictive factor, for renal branch occlusion

after branched endovascular repair, and then repeated from Mario Stella's group showing that upward-facing renal arteries have immediate technical problems when using branches, and if you have the combination of downward and then upward facing

the long term outcome is impaired if you use a branched approach. And we know for the renals that using a fenestrated phenotype seems to improve the outcomes, and this has been shown in multiple trials

where fenestrations for renals do better than branches. So then moving away from the phenotype to the mating stent. Does the type of mating stent matter? In branch repairs we looked at this

from these five major European centers in about 500 patients to see if the type of mating stent used for branch phenotype grafts mattered. It was very difficult to evaluate and you can see in this rather busy graph

that there was a combination used of self-expanding and balloon expandable covered stents in these situations. And in fact almost 2/3 of the patients had combinations in their grafts, so combining balloon expandable covered stents

with self expanding stents, and vice versa, making these analyses very very difficult. But what we could replicate, of course, was the earlier findings that the event rates with using branches for celiac and SMA were very low,

whereas they were significant for left renal arteries and if you saw the last session then in similar situations after open repair, although this includes not only occlusions but re-interventions of course.

And we know when we use fenestrations that where we have wall contact that using covered stents is generally better than using bare stents which we started out with but the type of covered stent

also seems to matter and this might be due to the stiffness of the stent or how far it protrudes into the target vessel. There is a multitude of new bridging stents available for BEVAR and FEVAR: Covera, Viabahn, VBX, and Bentley plus,

and they all seem to have better flexibility, better profile, and better radial force so they're easier to use, but there's no long-term data evaluating these devices. The technical success rate is already quite high for all of these.

So this is a summary. We've talked using branches versus fenestration and often a combination to design the device to the specific patient anatomy is the best. So in summary,

always use covered stents even when you do fenestrated grafts. At present, mix and match seems to be beneficial both with regards to the phenotype and the mating stent. Short term results seem to be good.

Technical results good and reproducible but long term results are lacking and there is very limited comparative data. Thank you. (audience applauding)

- Thank you very much, Gustavo, you read the abstract so now my task is to convince you that this very counter-intuitive technique actually works, you are familiar with Petticoat, cover stent to close a proximal entry tear and then uncover stents, bear stents, downstream. This what it would look like when we open up

the bare stent, you know dissect the aorta. So here's a case example, acute type B with malperfusion, the true lumen is sickle shaped, virtually occluded. So we use Petticoat, and we end up with a nice reopening of the true lumen, it is tagged here in green, however if you look more closely you see that here

wrapping around the true lumen there is a perfused false lumen. This is not an exception, not a complication, this is what happens in most cases, because there are always reentries in the celiac portion of the aorta.

So the Stablise concept was introduced by Australian group of Nixon, Peter Mossop in 2012, after you do the Petticoat, you are going to voluntarily balloon inside both the stent graft and the bare stents in order to disrupt, to fracture the lamel, obtain a single-channeled aorta.

This is what it looks like at TEE, after deployment of the stent graft, you see the stent graft does not open up completely, there is still some false lumen here, but after the ballooning, it is completely open. So the results were immediately very, very good, however technique did not gain a lot of consensus,

mainly because people were afraid of rupturing the aorta, they dissect the aorta. So here's a Stabilise case, once again, acute setting, malperfusion, we do a carotid subclavian bypass because we are going to cover the subclavian artery, we deploy

the cover stent graft, then with one stent overlap, we deploy two bare stent devices all the way down to the iliacs and then we start ballooning from the second stent down, so you see Coda balloon is used here, but only inside the cover stent with fabric.

And then more distally we are using a valvuloplastic balloon, which is noncompliant, and decides to be not larger than the aorta. So, I need probably to go here, this is the final result, you can see from the cross-sections that the dissection is completely gone and

the aorta is practically healed. So you might need also to address reentries at the iliac levels, attention if you have vessels that only come from the false lumen, we want to protect them during the ballooning, so we have a sheath inside this target vessel, and we are

going to use a stent afterwards to avoid fragments of the intima to get into the ostium of the artery. And this is a one-year control, so as you can see there is a complete remodeling of the aorta, the aorta is no longer dissected, it's a single channel vessel, here we can see stents in two vessels that came

from the false lumen, so very satisfactory. Once again, please remember, we use compliant latex balloons only inside the the cover stent graft, and in the bare stents we use non-compliant balloons. We have published our first cases, you can find more details in the journal paper, so in conclusion,

dear colleagues, Stabilise does work, however we do need to collect high-quality data and the international registry is the way to do this, we have the Stabilise registry which is approved by our ethical committee, we have this group of initial friends that are participating,

however this registry is physician initiated, it's on a voluntary base, it is not supported by industry, so we need all the possible help in order to get patients as quickly as possible, please join, just contact us at this email, we'd be more than happy to include everybody who is

doing this technique according to this protocol, in order to have hard data as soon as possible, thank you very much for your attention.

- Thank you. Thank you again for the invitation, and also my talk concerns the use of new Terumo Aortic stent graft for the arch. And it's the experience of three different countries in Europe. There's no disclosure for this topic.

Just to remind what we have seen, that there is some complication after surgery, with mortality and the stroke rate relatively high. So we try to find some solution. We have seen that we have different options, it could be debranching, but also

we know that there are some complications with this technique, with the type A aortic dissection by retrograde way. And also there's a way popular now, frozen elephant trunk. And you can see on the slide the principle.

But all the patients are not fit for this type of surgery. So different techniques have been developed for endovascular options. And we have seen before the principle of Terumo arch branch endograft.

One of the main advantages is a large window to put the branches in the different carotid and brachiocephalic trunk. And one of the benefit is small, so off-the-shelf technique, with one size for the branch and different size

for the different carotids. This is a more recent experience, it's concerning 15 patients. And you can see the right column that it is. All the patients was considered unfit for conventional surgery.

If we look about more into these for indication, we can see four cases was for zone one, seven cases for zone two, and also four cases for zone three. You can see that the diameter of the ascending aorta, the min is 38,

and for the innominate artery was 15, and then for left carotid was eight. This is one example of what we can obtain with this type of handling of the arch with a complete exclusion of the lesion, and we exclude the left sonography by plyf.

This is another, more complex lesion. It's actually a dissection and the placement of a stent graft in this area. So what are the outcomes of patients? We don't have mortality, one case of hospital mortality.

We don't have any, sorry, we have one stroke, and we can see the different deaths during the follow-up. If we look about the endoleaks, we have one case of type three endoleak started by endovascular technique,

and we have late endoleaks with type one endoleaks. In this situation, it could be very difficult to treat the patient. This is the example of what we can observe at six months with no endoleak and with complete exclusion of the lesion.

But we have seen at one year with some proximal type one endoleak. In this situation, it could be very difficult to exclude this lesion. We cannot propose this for this patient for conventional surgery, so we tried

to find some option. First of all, we tried to fix the other prosthesis to the aortic wall by adjusted technique with a screw, and we can see the fixation of the graft. And later, we go through the,

an arrangement inside the sac, and we put a lot of colors inside so we can see the final results with complete exclusion. So to conclude, I think that this technique is very useful and we can have good success with this option, and there's a very low

rate of disabling stroke and endoleaks. But, of course, we need more information, more data. Thank you very much for your attention.

- And thanks to Dr. Veith for the opportunity to get involved. Here's my disclosures. Like so many in the audience, for years and years we've had awesome results with the AngioJet from Boston Sci. We know that this rheolytic system works quite well.

However it has a black box warning for PE due to the hemolysis and the adenosine that can be extruded out. It's oftentimes not stand alone. It's not used for stroke and there can be some renal issues. But we've had excellent results with it over the years,

but at the end of the day often times you still need lytics. And I think Professor Davies just eluded to the potential problems not only medical, but legal as well of lytics. Therefore for the past four plus years we've utilized this as well as other thrombectomy devices.

This is the Indigo device from Penumbra. I'm certain by now most of your are familiar with it, but if not what it is it's a braided catheter that's very atraumatic and soft at the tip. It can come straight in or torqued so you can have some directionality to it.

And then what it also has is this separator technology which is really just like a glorified pipe cleaner to be honest. You're going to go in and out with this device as I'll show you here in a second, to clear the lumen while you're

allowing for continuous aspiration through this system. We learned from our neurosurgery colleagues who utilized typically the CAT five, sometimes six for their stroke patients, but now there's CAT three, five, six, and eight. And within the next probably three to four months

there's going to be CAT 10 or possibly even 12 out there. This is what you have. It's all pretty simple. You cross your lesion with the wire. You then bring your catheter across. You connect it to this suction device,

hit the green button and away you go. You get maximal aspiration. And what's nice about it is in particular for the CAT eight with the XTORQ, as you can see you can get out to vessel 25 millimeters in diameter.

So essentially a cava. This shows you how powerful this is. This is one of my patient's with a standard nitinol stent. A Zilver PTX was occluded and you can see how powerful this device

is with maximal aspiration. Turn it off and obviously the self expanding stent goes right back to normal. So after our results with the ALI patients, and we presented our data at the Midwest meeting in St. Louis earlier this fall,

we start looking at our DVT patients and here you can see an effort thrombosis. Somebody here. We went eight French basilic. Ultrasound guided. Put an eight French Indigo in and with no lytics,

were able to clean this out. We then went on to, I put him on a DOAC. Today I'd probably use Lovenox for two weeks. And then he went home. He's a 32 year old.

Went to Disney World with his family and then came back later on for is infraclavicular rib excision. Here's another one of my patients, Lena. She's a 19 year old who started her OPCs on the way back to Bellarmine College in Louisville.

And as you can see here, she is a likely underlying May Thurner lesion. Extensive of femoral DVT. As you look over here to the screen left to screen right, you can see that we crossed it, put our catheter up in the common iliac vein,

as as you can see we're twisting it around to get to the edges of the vessel, the whole iliofemoral system. Here's what you get afterwards. You get antegrade flow. Certainly there's no device yet that's perfect at this.

For this particular patient we gave her 14 milligrams of lytics then did our IVUS then did our wallstent. And she's done quite well. We use it for arms. We use it for legs.

We use it for filters as well as you can see here with this occluded filter. And often times the picture you're going to get is an underlying acute on chronic thrombosis here. And we later on came back and took that filter out. So I think there's no question there's less lytics with it.

Earlier this year we presented at the American Venous Forum in Tucson. Our initial experiences with vacuum-assisted thrombectomy for DVT. And what showed is that often times you can get antegrade flow as I'll show you here.

Some of them are single sessions. But more importantly just as efficacious as it is it's safe. You can see here that we had minimal blood loss, low transfusions, and here's our breakdown. As we use it for all venous pathologies as you can see.

So at the time when we looked at our first 20, you can see that there were some that were single session therapy. And that's before. We've now added the turbo pulse technique where you're going to lace it with

14 milligrams of TPA through a unifused catheter, wait 20 minutes, go around get some coffee, whatever you need to do, come back and then use the Indigo. So at the end of the day, I think as Professor Davies eluded to, there are major complications with lytics.

This is not what we need for our patients. So in 2018 we can either continue to load with dangerous lytics or minimize lytics, adopt continuous aspiration thrombectomy. It's your all's choice. So thanks so much.

- I want to thank Dr. Veith for the invitation to present this. There are no disclosures. So looking at cost effectiveness, especially the comparison of two interventions based on cost and the health gains, which is usually reported

through disability adjusted life years or even qualities. It's not to be really confused with cost benefit analysis where both paramaters are used, looked at based on cost. However, this does have different implications from different stakeholders.

And we look, at this point, between the medical center or the medical institution and as well as the payers. Most medical centers tend to look at how much this is costing them

and what is being reimbursed. What's the subsequent care interventions and are there any additional payments for some of these new, novel technologies. What does the payers really want to know, what are they getting for the money,

their expenditures and from here, we'll be looking mainly at Medicare. So, background, we've all seen this, but basically, you know, balloon angioplasty and stents have been out for a while and the outcomes aren't bad but they're not great.

They do have continued high reintervention rates and patency problems. Therefore, drug technology has sort of emerged as a possible alternative with better patency rates. And when we look at this, just some, some backgrounds, when you look at any sort of angioplasty,

from the physician's side, we bill under a certain CPT code and it falls under a family of codes for reimbursement in the medical center called an APC. Within those, you can further break it down to the cost of the product.

In this situation, total products cost around 1400 dollars and the balloons are estimated to be 406 dollars in cost. However, in drug-coated balloons, there was an additional payment, which average, because they're such more expensive devices than the allotments and this had an additional payment.

However, this expired in January of this year. When you look at Medicare reimbursement guidelines, you'll see that on an outpatient hospital setting, there's a reimbursement for the medical center as well as for the physican which is, oops sorry, down eight percent from last year.

And they also publish a geometric mean cost, which is quite higher than we expected. And then the office based practice is also the reimbursement pattern and this is slated to go down also by a few percentage points.

When you look at, I'm sorry, when you look at stents, however, it's a different family of CPT codes and APC family also. Here you'll see the supply cost is much higher in the, I'm sorry, the stent in this category is actually 3600 dollars.

The average cost for drug-eluting stents, around 1500 dollars and the only pass through that existed was on the inpatient side of it. Again, looking at Medicare guidelines, the reimbursement will be going down 8 percent

for the outpatient setting and the geometric mean cost is 11,700. So, what we want to look at really is what is the financial impact looking at primary patency, target lesion revascularization based on meta analysis. And the reinterventions are where the real cost

is going to come into effect. We also want to look at, when it doesn't work and we do bailout stenting, what is the cost going to happen there, which is not often looked at in most of these studies. So looking at a hypothetical situation,

you've got 100 patients, any office based practice, the payee will pay about 5145. There's a pass through payment which averages 1700 dollars per stent. Now, if you look at bailout stenting, 18.5 percent at one year,

this is the additional cost that would be associated with that from a payer standpoint. Targeted risk for revascularization was 12 percent of additional costs. So the total one year cost, we estimated, was almost a million dollars

and the cost per primary patency limb at one year was 13 four. In a similar fashion, for drug-eluting stents, you'll see that there's no pass through payment, but although there is a much higher payer expenditure. The reintervention rate was about 8.4 percent

at one year for the additional cost. And you'll see here, at the one year mark, the cost per patent limb is about 12,600 dollars. So how 'about the medical center, looking at Medicare claims data, you'll see the average cost for them is 745,000,

the medical center. Additional costs listed at another 1500. Bailout renting, as previously, with relate to a total cost at one year of 1.2 million or at 16,900 dollars per limb. Looking at the drug-eluting stents,

we didn't add any additional costs because the drug-eluting stents are cheaper than the current system that is in there but the reinterventions still exist for a cost per patent limb at one year of 14 six. So in essence, a few other studies have looked

at some model, both a European model and in the U.S. where the number of reinterventions at two to five years will actually offset the additional cost of drug-eluting stents and make it a financially advantageous process.

And in conclusion, drug-eluting stents do have a better primary patency and a decreased TLR than drug-coated balloons or even other, but they are more expensive than conventional treatment such as balloon angioplasty and bare-metal stents.

There is a decreased reintervention rate and the bailout stenting, which is not normally accounted for in a financial standpoint does have a dramatic impact and the loss of the pass through makes me make some of the drug-coated balloons

a little more prohibitive in process. Thank you.

- Good morning, thank you, Dr. Veith, for the invitation. My disclosures. So, renal artery anomalies, fairly rare. Renal ectopia and fusion, leading to horseshoe kidneys or pelvic kidneys, are fairly rare, in less than one percent of the population. Renal transplants, that is patients with existing

renal transplants who develop aneurysms, clearly these are patients who are 10 to 20 or more years beyond their initial transplantation, or maybe an increasing number of patients that are developing aneurysms and are treated. All of these involve a renal artery origin that is

near the aortic bifurcation or into the iliac arteries, making potential repair options limited. So this is a personal, clinical series, over an eight year span, when I was at the University of South Florida & Tampa, that's 18 patients, nine renal transplants, six congenital

pelvic kidneys, three horseshoe kidneys, with varied aorto-iliac aneurysmal pathologies, it leaves half of these patients have iliac artery pathologies on top of their aortic aneurysms, or in place of the making repair options fairly difficult. Over half of the patients had renal insufficiency

and renal protective maneuvers were used in all patients in this trial with those measures listed on the slide. All of these were elective cases, all were technically successful, with a fair amount of followup afterward. The reconstruction priorities or goals of the operation are to maintain blood flow to that atypical kidney,

except in circumstances where there were multiple renal arteries, and then a small accessory renal artery would be covered with a potential endovascular solution, and to exclude the aneurysms with adequate fixation lengths. So, in this experience, we were able, I was able to treat eight of the 18 patients with a fairly straightforward

endovascular solution, aorto-biiliac or aorto-aortic endografts. There were four patients all requiring open reconstructions without any obvious endovascular or hybrid options, but I'd like to focus on these hybrid options, several of these, an endohybrid approach using aorto-iliac

endografts, cross femoral bypass in some form of iliac embolization with an attempt to try to maintain flow to hypogastric arteries and maintain antegrade flow into that pelvic atypical renal artery, and a open hybrid approach where a renal artery can be transposed, and endografting a solution can be utilized.

The overall outcomes, fairly poor survival of these patients with a 50% survival at approximately two years, but there were no aortic related mortalities, all the renal artery reconstructions were patented last followup by Duplex or CT imaging. No aneurysms ruptures or aortic reinterventions or open

conversions were needed. So, focus specifically in a treatment algorithm, here in this complex group of patients, I think if the atypical renal artery comes off distal aorta, you have several treatment options. Most of these are going to be open, but if it is a small

accessory with multiple renal arteries, such as in certain cases of horseshoe kidneys, you may be able to get away with an endovascular approach with coverage of those small accessory arteries, an open hybrid approach which we utilized in a single case in the series with open transposition through a limited

incision from the distal aorta down to the distal iliac, and then actually a fenestrated endovascular repair of his complex aneurysm. Finally, an open approach, where direct aorto-ilio-femoral reconstruction with a bypass and reimplantation of that renal artery was done,

but in the patients with atypical renals off the iliac segment, I think you utilizing these endohybrid options can come up with some creative solutions, and utilize, if there is some common iliac occlusive disease or aneurysmal disease, you can maintain antegrade flow into these renal arteries from the pelvis

and utilize cross femoral bypass and contralateral occlusions. So, good options with AUIs, with an endohybrid approach in these difficult patients. Thank you.

- Thank you Mr. Chairman, good morning ladies and gentlemen. So that was a great setting of the stage for understanding that we need to prevent reinterventions of course. So we looked at the data from the DREAM trial. We're all aware that we can try

to predict secondary interventions using preoperative CT parameters of EVAR patients. This is from the EVAR one trial, from Thomas Wyss. We can look at the aortic neck, greater angulation and more calcification.

And the common iliac artery, thrombus or tortuosity, are all features that are associated with the likelihood of reinterventions. We also know that we can use postoperative CT scans to predict reinterventions. But, as a matter of fact, of course,

secondary sac growth is a reason for reintervention, so that is really too late to predict it. There are a lot of reinterventions. This is from our long term analysis from DREAM, and as you can see the freedom, survival freedom of reinterventions in the endovascular repair group

is around 62% at 12 years. So one in three patients do get confronted with some sort of reintervention. Now what can be predicted? We thought that the proximal neck reinterventions would possibly be predicted

by type 1a Endoleaks and migration and iliac thrombosis by configurational changes, stenosis and kinks. So the hypothesis was: The increase of the neck diameter predicts proximal type 1 Endoleak and migration, not farfetched.

And aneurysm shrinkage maybe predicts iliac limb occlusion. Now in the DREAM trial, we had a pretty solid follow-up and all patients had CT scans for the first 24 months, so the idea was really to use

those case record forms to try to predict the longer term reinterventions after four, five, six years. These are all the measurements that we had. For this little study, and it is preliminary analysis now,

but I will be presenting the maximal neck diameter at the proximal anastomosis. The aneurysm diameter, the sac diameter, and the length of the remaining sac after EVAR. Baseline characteristics. And these are the re-interventions.

For any indications, we had 143 secondary interventions. 99 of those were following EVAR in 54 patients. By further breaking it down, we found 18 reinterventions for proximal neck complications, and 19 reinterventions

for thrombo-occlusive limb complications. So those are the complications we are trying to predict. So when you put everything in a graph, like the graphs from the EVAR 1 trial, you get these curves,

and this is the neck diameter in patients without neck reintervention, zero, one month, six months, 12, 18, and 24 months. There's a general increase of the diameter that we know.

But notice it, there are a lot of patients that have an increase here, and never had any reintervention. We had a couple of reinterventions in the long run, and all of these spaces seem to be staying relatively stable,

so that's not helping much. This is the same information for the aortic length reinterventions. So statistical analysis of these amounts of data and longitudinal measures is not that easy. So here we are looking at

the neck diameters compared for all patients with 12 month full follow-up, 18 and 24. You see there's really nothing happening. The only thing is that we found the sac diameter after EVAR seems to be decreasing more for patients who have had reinterventions

at their iliac limbs for thrombo-occlusive disease. That is something we recognize from the literature, and especially from these stent grafts in the early 2000s. So conclusion, Mr. Chairman, ladies and gentlemen, CT changes in the first two months after EVAR

predict not a lot. Neck diameter was not predictive for neck-reinterventions. Sac diameter seems to be associated with iliac limb reinterventions, and aneurysm length was not predictive

of iliac limb reinterventions. Thank you very much.

- Thank you (mumbles) and thank you Dr. Veith for the kind invitation to participate in this amazing meeting. This is work from Hamburg mainly and we all know that TEVAR is the first endovascular treatment of choice but a third of our patients will fail to remodel and that's due to the consistent and persistent

flow in the false lumen over the re-entrance in the thoracoabdominal aorta. Therefore it makes sense to try to divide the compartments of the aorta and try to occlude flow in the false lumen and this can be tried by several means as coils, plug and glue

but also iliac occluders but they all have the disadvantage that they don't get over 24 mm which is usually not enough to occlude the false lumen. Therefore my colleague, Tilo Kolbel came up with this first idea with using

a pre-bulged stent graft at the midportion which after ballooning disrupts the dissection membrane and opposes the outer wall and therefore occludes backflow into the aneurysm sac in the thoracic segment, but the most convenient

and easy to use tool is the candy-plug which is a double tapered endograft with a midsegment that is 18 mm and once implanted in the false lumen at the level of the supraceliac aorta it occludes the backflow in the false lumen in the thoracic aorta

and we have seen very good remodeling with this approach. You see here a patient who completely regressed over three years and it also answers the question how it behaves with respect to true and false lumen. The true lumen always wins and because once

the false lumen thrombosis and the true lumen also has the arterial pressure it does prevail. These are the results from Hamburg with an experience of 33 patients and also the international experience with the CMD device that has been implanted in more than 20 cases worldwide

and we can see that the interprocedural technical success is extremely high, 100% with no irrelevant complications and also a complete false lumen that is very high, up to 95%. This is the evolvement of the candy-plug

over the years. It started as a surgeon modified graft just making a tie around one of the stents evolving to a CMD and then the last generation candy-plug II that came up 2017 and the difference, or the new aspect

of the candy-plug II is that it has a sleeve inside and therefore you can retrieve the dilator without having to put another central occluder or a plug in the central portion. Therefore when the dilator is outside of the sleeve the backflow occludes the sleeve

and you don't have to do anything else, but you have to be careful not to dislodge the whole stent graft while retrieving the dilator. This is a case of a patient with post (mumbles) dissection.

This is the technique of how we do it, access to the false lumen and deployment of the stent graft in the false lumen next to the true lumen stent graft being conscious of the fact that you don't go below the edge of the true lumen endograft

to avoid (mumbles) and the final angiography showing no backflow in the aneurysm. This is how we measure and it's quite simple. You just need about a centimeter in the supraceliac aorta where it's not massively dilated and then you just do an over-sizing

in the false lumen according to the Croissant technique as Ste-phan He-lo-sa has described by 10 to 30% and what is very important is that in these cases you don't burn any bridges. You can still have a good treatment

of the thoracic component and come back and do the fenestrated branch repair for the thoracoabdominal aorta if you have to. Thank you very much for your attention. (applause)

- Thanks (mumbles) I have no disclosures. So when were talking about treating thoracoabdominal aortic aneurysms in patients with chronic aortic dissections, these are some of the most difficult patients to treat. I thought it would be interesting

to just show you a case that we did. This is a patient, you can see the CT scrolling through, Type B dissection starts pretty much at the left subclavian, aneurysmal. It's extensive dissection that involves the thoracic aorta, abdominal aorta,

basically goes down to the iliac arteries. You can see the celiac, SMA, renals at least partially coming off the true and continues all the way down. It's just an M2S reconstruction. You can see again the extent of this disease and what makes this so difficult in that it extends

from the entire aorta, up proximally and distally. So what we do for this patient, we did a left carotid subclavian bypass, a left external to internal iliac artery bypass. We use a bunch of thoracic stent grafts and extended that distally.

You can see we tapered down more distally. We used an EVAR device to come from below. And then a bunch of parallel grafts to perfuse our renals and SMA. I think a couple take-home messages from this is that clearly you want to preserve the branches

up in the arch. The internal iliac arteries are, I think, very critical for perfusing the spinal cord, especially when you are going to cover this much. And when you are dealing with these dissections, you have to realize that the true lumens

can become quite small and sometimes you have to accommodate for that by using smaller thoracic endografts. So this is just what it looks like in completion. You can see how much metal we have in here. It's a full metal jacket of the aorta, oops.

We, uh, it's not advancing. Oops, is it 'cause I'm pressing in it or? All right, here we go. And then two years post-op, two years post-op, you can see what this looks like. The false lumen is completely thrombosed and excluded.

You can see the parallel grafts are all open. The aneurysm sac is regressing and this patient was successfully treated. So what are some of the tips and tricks of doing these types of procedures. Well we like to come in from the axillary artery.

We don't perform any conduits. We just stick the axillary artery separately in an offset manner and place purse-string sutures. You have to be weary of manipulating around the aortic arch, especially if its a more difficult arch, as well as any thoracic aortic tortuosity.

Cannulating of vessels, SMA is usually pretty easy, as you heard earlier. The renals and celiac can be more difficult, depending upon the angles, how they come off, and the projection. You want to make sure you maintain a stiff wire,

when you do get into these vessels. Using a Coda balloon can be helpful, as sometimes when you're coming from above, the wires and catheters will want to reflux into that infrarenal aorta. And the Coda balloon can help bounce that up.

What we do in situations where the Coda doesn't work is we will come in from below and a place a small balloon in the distal renal artery to pin the catheters, wires and then be able to get the stents in subsequently. In terms of the celiac artery,

if you're going to stent it, you want to make sure, your wire is in the common hepatic artery, so you don't exclude that by accident. I find that it is just simpler to cover, if the collaterals are intact. If there is a patent GDA on CT scan,

we will almost always cover it. You can see here that robust collateral pathway through the GDA. One thing to be aware of is that you are going to, if you're not going to revascularize the celiac artery you may need to embolize it.

If its, if the endograft is not going to oppose the origin of the celiac artery in the aorta because its aneurysmal in that segment. In terms of the snorkel extent, you want to make sure, you get enough distal purchase. This is a patient intra-procedurally.

We didn't get far enough and it pulled out and you can see we're perfusing the sac. It's critical that the snorkel or parallel grafts extend above the most proximal extent of your aortic endograft or going to go down. And so we take a lot of care looking at high resolution

pictures to make sure that our snorkel and parallel grafts are above the aortic endograft. This is just a patient just about a year or two out. You can see that the SMA stent is pulling out into the sac. She developed a endoleak from the SMA,

so we had to come in and re-extend it more distally. Just some other things I mentioned a little earlier, you want to consider true lumen space preserve the internals, and then need to sandwich technique to shorten the parallel grafts. Looking at a little bit of literature,

you can see this is the PERCLES Registry. There is a number of type four thoracos that are performed here with good results. This is a paper looking at parallel grafting and 31 thoracoabdominal repairs. And you can see freedom from endoleaks,

chimney graft patency, as well as survival is excellent. This was one looking purely at thoracoabdominal aneurysm repairs. There are 32 altogether and the success rates and results were good as well. And this was one looking at ruptures,

where they found that there was a mean 20% sac shrinkage rate and all endografts remained patent. So conclusion I think that these are quite difficult to do, but with good techniques, they can be done successfully. Thank you.

- Well, thank you Frank and Enrico for the privilege of the podium and it's the diehards here right now. (laughs) So my only disclosure, this is based on start up biotech company that we have formed and novel technology really it's just a year old

but I'm going to take you very briefly through history very quickly. Hippocrates in 420 B.C. described stroke for the first time as apoplexy, someone be struck down by violence. And if you look at the history of stroke,

and trying to advance here. Let me see if there's a keyboard. - [Woman] Wait, wait, wait, wait. - [Man] No, there's no keyboard. - [Woman] It has to be opposite you. - [Man] Left, left now.

- Yeah, thank you. Are we good? (laughs) So it's not until the 80s that really risk factors for stroke therapy were identified, particularly hypertension, blood pressure control,

and so on and so forth. And as we go, could you advance for me please? Thank you, it's not until the 90s that we know about the randomized carotid trials, and advance next slide please, really '96 the era of tPA that was

revolutionary for acute stroke therapy. In the early 2000s, stroke centers, like the one that we have in the South East Louisiana and New Orleans really help to coordinate specialists treating stroke. Next slide please.

In 2015, the very famous HERMES trial, the compilation of five trials for mechanical thrombectomy of intracranial middle and anterior cerebral described the patients that could benefit and we will go on into details, but the great benefit, the number needed to treat

was really five to get an effect. Next slide. This year, "wake up" strokes, the extension of the timeline was extended to 24 hours, increase in potentially the number of patients that could be treated with this technology.

Next please. And the question is really how can one preserve the penumbra further to treat the many many patients that are still not offered mechanical thrombectomy and even the ones that are, to get a much better outcome because not everyone

returns to a normal function. Next, so the future I think is going to be delivery of a potent neuroprotection strategy to the penumbra through the stroke to be able to preserve function and recover the penumbra from ongoing death.

Next slide. So that's really the history of stroke. Advance to the next please. Here what you can see, this is a patient of mine that came in with an acute carotid occlusion that we did an emergency carotid endarterectomy

with an neuro interventionalist after passage of aspiration catheter, you can see opening of the middle cerebral M1 and M2 branches. The difference now compared to five, eight, 10 years ago is that now we have catheters in the middle cerebral artery,

the anterior cerebral artery. After tPA and thrombectomy for the super-selective, delivery of a potent neuroprotective agent and by being able to deliver it super-selectively, bioavailability issues can be resolved, systemic side effects could be minimized.

Of course, it's important to remember that penumbra is really tissue at risk, that's progression towards infarction. And everybody is really different as to when this occurs. And it's truly all based on collaterals.

So "Time is brain" that we hear over and over again, at this meeting there were a lot of talks about "Time is brain" is really incorrect. It's really "Collaterals are brain" and the penumbra is really completely based on what God gives us when we're born, which is really

how good are the collaterals. So the question is how can the penumbra be preserved after further mechanical thrombectomy? And I think that the solution is going to be with potent neuroprotection delivery to the penumbra. These are two papers that we published in late 2017

in Nature, in science journals Scientific Reports and Science Advances by our group demonstrating a novel class of molecules that are potent neuroprotective molecules, and we will go into details, but we can discuss it if there's interest, but that's just one candidate.

Because after all, when we imaged the penumbra in acute stroke centers, again, it's all about collaterals and I'll give you an example. The top panel is a patient that comes in with a good collaterals, this is a M1 branch occlusion. In these three phases which are taken at

five second intervals, this patient is probably going to be offered therapy. The patients that come in with intermediate or poor collaterals may or may not receive therapy, or this patient may be a no-go. And you could think that if neuroprotection delivery

to the penumbra is able to be done, that these patients may be offered therapy which they currently are not. And even this patient that's offered therapy, might then leave with a moderate disability, may have a much better functional

independence upon discharge. When one queries active clinical trials, there's nothing on intra arterial delivery of a potent neuroprotection following thrombectomy. These are two trials, an IV infusion, peripheral infusion, and one on just verapamil to prevent vasospasm.

So there's a large large need for delivery of a potent neuroprotection following thrombectomy. In conclusion, we're in the door now where we can do mechanical thrombectomy for intracranial thrombus, obviously concomitant to what we do in the carotid bifurcation is rare,

but those patients do present. There's still a large number of patients that are still not actively treated, some estimate 50 to 60% with typical mechanical thrombectomy. And one can speculate how ideally delivery of a potent neuroprotection to this area could

help treat 50, 60% of patients that are being denied currently, and even those that are being treated could have a much better recovery. I'd like to thank you, Frank for the meeting, and to Jackie for the great organization.

- Thank you. Historically, common femoral endarterectomy is a safe procedure. In this quick publication that we did several years ago, showed a 1.5% 30 day mortality rate. Morbidity included 6.3% superficial surgical site infection.

Other major morbidity was pretty low. High-risk patients we identified as those that were functionally dependent, dyspnea, obesity, steroid use, and diabetes. A study from Massachusetts General Hospital their experience showed 100% technical success.

Length of stay was three days. Primary patency of five years at 91% and assisted primary patency at five years 100%. Very little perioperative morbidity and mortality. As you know, open treatment has been the standard of care

over time the goal standard for a common femoral disease, traditionally it's been thought of as a no stent zone. However, there are increased interventions of the common femoral and deep femoral arteries. This is a picture that shows inflection point there.

Why people are concerned about placing stents there. Here's a picture of atherectomy. Irritational atherectomy, the common femoral artery. Here's another image example of a rotational atherectomy, of the common femoral artery.

And here's an image of a stent there, going across the stent there. This is a case I had of potential option for stenting the common femoral artery large (mumbles) of the hematoma from the cardiologist. It was easily fixed

with a 2.5 length BioBond. Which I thought would have very little deformability. (mumbles) was so short in the area there. This is another example of a complete blow out of the common femoral artery. Something that was much better

treated with a stent that I thought over here. What's the data on the stenting of the endovascular of the common femoral arteries interventions? So, there mostly small single centers. What is the retrospective view of 40 cases?

That shows a restenosis rate of 19.5% at 12 months. Revascularization 14.1 % at 12 months. Another one by Dr. Mehta shows restenosis was observed in 20% of the patients and 10% underwent open revision. A case from Dr. Calligaro using cover stents

shows very good primary patency. We sought to use Vascular Quality Initiative to look at endovascular intervention of the common femoral artery. As you can see here, we've identified a thousand patients that have common femoral interventions, with or without,

deep femoral artery interventions. Indications were mostly for claudication. Interventions include three-quarters having angioplasty, 35% having a stent, and 20% almost having atherectomy. Overall technical success was high, a 91%.

Thirty day mortality was exactly the same as in this clip data for open repair 1.6%. Complications were mostly access site hematoma with a low amount distal embolization had previously reported. Single center was up to 4%.

Overall, our freedom for patency or loss or death was 83% at one year. Predicted mostly by tissue loss and case urgency. Re-intervention free survival was 85% at one year, which does notably include stent as independent risk factor for this.

Amputation free survival was 93% at one year, which factors here, but also stent was predictive of amputation. Overall, we concluded that patency is lower than historical common femoral interventions. Mortality was pretty much exactly the same

that has been reported previously. And long term analysis is needed to access durability. There's also a study from France looking at randomizing stenting versus open repair of the common femoral artery. And who needs to get through it quickly?

More or less it showed no difference in outcomes. No different in AVIs. Higher morbidity in the open group most (mumbles) superficial surgical wound infections and (mumbles). The one thing that has hit in the text of the article

a group of mostly (mumbles) was one patient had a major amputation despite having a patent common femoral artery stent. There's no real follow up this, no details of this, I would just caution of both this and VQI paper showing increased risk amputation with stenting.

Thank you.

- Like to thank Dr. Veith and the committee for asking me to speak. I have no conflicts related to this presentation. Labial and vulvar varicosities occur in up to 10% of pregnant women, with the worst symptoms being manifested in the second half of the pregnancy.

Symptoms include genital pressure and fullness, pruritus, and a sensation of prolapse. These generally worsen with standing. Management is usually conservative. Between compression hose, cooling packs, and exercise, most women can make it through to the end of the pregnancy.

When should we do more than just reassure these women? An ultrasound should be performed when there's an early presentation, meaning in the first trimester, as this can be an unmasking of a venous malformation. If there are unilateral varicosities,

an ultrasound should be performed to make sure that these aren't due to iliac vein thrombosis. If there's superficial thrombosis or phlebitis, you may need to rule out deep venous extension with an ultrasound. When should we intervene?

You may need to intervene to release trapped blood in phlebitis, or to give low molecular weight heparin for comfort. When should a local phlebectomy or sclerotherapy be performed? Should sclerotherapy be performed during pregnancy?

We know very little. Occasionally, this is performed in a patient who is unknowingly pregnant, and there have been no clear complications from this in the literature. The effectiveness of sclero may also

be diminished in pregnancy, due to hormones and increased venous volume. Both polidocanol and sodium tetradecyl sulfate say that there is no support for use during pregnancies, and they advise against it. So what should you do?

This following case is a 24 year old G2P1, who was referred to me at 24 weeks for disabling vaginal and pelvic discomfort. She couldn't go to work, she couldn't take care of her toddler, she had some left leg complaints, but it was mostly genital discomfort and fullness,

and her OB said that he was going to do a pre-term C-section because he was worried about the risk of hemorrhage with the delivery. So this is her laying supine pre-op, and this is her left leg with varicosities visible in the anterior and posterior aspects.

Her ultrasound showed open iliac veins and large refluxing varicosities in the left vulvar area. She had no venous malformation or clot, and she had reflux in the saphenofemoral junction and down the GSV. I performed a phlebectomy on her,

and started with an ultrasound mapping of her superficial veins and perforators in the labial region. I made small incision with dissection and tie ligation of all the varicosities and perforators, and this was done under local anesthesia

with minimal sedation in the operating room. This resulted in vastly improved comfort, and her anxiety, and her OB's anxiety were both decreased, and she went on to a successful delivery. So this diagram shows the usual location of the labial perforators.

Here she is pre-op, and then here she is a week post-op. Well, what about postpartum varicosities? These can be associated with pelvic congestion, and the complaints can often be split into local, meaning surface complaints, versus pelvic complaints.

And this leads into a debate between a top down treatment approach, where you go in and do a venogram and internal coiling, versus a bottom up approach, where you start with local therapy, such as phlebectomy or sclero.

Pelvic symptoms include aching and pressure in the pelvis. These are usually worse with menstruation, and dyspareunia is most pronounced after intercourse, approximately an hour to several hours later. Surface complaints include vulvar itching, tenderness, recurrent thrombophlebitis, or bleeding.

Dyspareunia is present during or at initiation of sexual intercourse. I refer to this as the Gibson Algorithm, as Kathy Gibson and I have talked about this problem a lot, and this is how we both feel that these problems should be addressed.

If you have an asymptomatic or minimally symptomatic patient who's referred for varicosities that are seen incidentally, such as during a laparoscopy, those I don't treat. If you have a symptomatic patient who has pelvic symptoms, then these people get a venogram with coils and sclerotherapy as appropriate.

If they are not pregnant, and have no pelvic symptoms, these patients get sclero. If they are pregnant, and have no pelvic symptoms, they get a phlebectomy. In conclusion, vulvar varicosities are a common problem, and usually conservative management is adequate.

With extreme symptoms, phlebectomy has been successful. Pregnancy-related varicosities typically resolve post-delivery, and these can then be treated with local sclerotherapy if they persist. Central imaging and treatment is successful for primarily pelvic complaints or persistent symptoms.

Thank you.

- [Audience Member 1] So I have a question for Dr. Jackson, but maybe everybody else on the panel can chip in, and it just has to do with what your first intervention is going to be for a focal stenosis in a vein graft, and I guess, Ben, my question is, in general, is your first time you intervene going to be a drug-eluding stent?

Our strategy generally has been, to start with, a cutting balloon based on a series, I think it was from Schneider, who compared it and saw pretty good results. Nowadays, I think maybe I'd do that, and at the same time then put a drug-coated balloon in, and that's

increasing the cost, there's no good data to say that's better than just a cutting balloon, but I think I might do that and reserve the drug-eluding stent for the second time or third time. So my question is, what's your intervention the first time you intervene endovascularly

for a focal vein graft stenosis? - [Dr. Benjamin Jackson] So if you're not going to do an open revision, right, we'll preface with that, I'll use a coronary drug-eluding stent first. - [Audience Member 1] Okay. - [Speaker 1] Okay, so, are you happy with that?

- [Audience Member 1] Well, I was hoping to get other opinions, but if you want to move on, that's fine. - [Speaker 1] Alright, so I'll give you my opinion. I don't think there's anything wrong with putting a stent. The idea that the stent is going to be occupying space and is going to mess up your next procedure, I think

that's more out of fear than actually the reality. We have patients that in the SFA popliteal segmentary, we're on the fifth round of stents, and you'd be surprised how you can distend the fifth stent inside the SFA. I never thought it was possible, actually.

We have some IBIS documentation showing at least a five millimeter lumen after you do that thing. So I'm not so concerned about that. The problem with this, and I agree with putting a stent because there's a very rigid lesion sometimes. It's not easy to balloon them, it's not easy to

because usually the cutting balloon probably already got the lumen that you want, but then definitely it increases the cost that way. Again, who knows the other answer. Anybody else? - [Dr. Chris Metzger] Yeah, a brief comment.

I don't think all vein graft lesions are alike, so it depends if it's diffused or focal. The other thing is, I think your response to initial therapy is important, so if you do your balloon, cutting balloon, then it's going to tell you recoil, not recoil,

and the other thing I would say is intravascular ultrasound, if you're in doubt on how large that is, I think helps a lot. So, you know, if it's very focal, very high grade, I think drug-eluding stent is perfect, the question is what size, IBIS helps with that.

Otherwise, I think your strategy for longer disease might be a reasonable strategy as well. - [Dr. George Adams] And the only other comment I'd make is if there is a thrombotic component like Chris was saying, depending on the client morphology I might use laser atherectomy followed by a

biologic therapy such as a drug-coated balloon. - [Speaker 1] Yes, sir? - [Audience Member 2] About that last presentation, are you using any type of anticoagulation when you do these PTFE tibial bypasses, or were the groups comparable where there's only antiplatelet

therapy in the vein grafts and in the prosthetic grafts, or are you putting all of them on factor 10A inhibitor coumadin? - [Dr. Peter Lin] So our patient, we typically put them on aspirin, and for the Propaten we don't add any distal antiplatelet agents.

- [Audience Member 2] Because that's a lot better than historical reports, probably. I wondered, why do you think it shows so much better, even with previous vein cusp patches? - [Dr. Peter Lin] So I think the patch matters, and I also think that over the years, we also learned

a whole lot about the distal anastomotic patch, because time won't let me tell you something and go into great detail. So the patch, you know, we make, is about two to two and a half centimeter long, so that length of the patch is almost twice the length of

the diameter of the graft itself, so I think that's also a significant factor. So it's something that previous literature has not really emphasized on, and the PTFE ideally should be connected to the proximal one-third, instead of distal one-third, so that also may make

some of the same area boost configuration. So the whole idea is you want to make the patch as long distally as possible. So some of the variations, I think, have in part helped, and ideally is that the vein is available, that would be great, if not we also have used a lot

of bovine patch as our patch material, so that thing I think made a lot of difference. So I don't think, all things considered, antiplatelet agents played a huge role, but I think the distal anastomotic compliance mismatch, if we can alleviate that, it will help your outcome.

- [Speaker 1] So Peter, you believe that those grafts have a thrombotic threshold, or you think there's no thrombotic threshold for PTFE? - [Dr. Peter Lin] Oh, I think so. - [Speaker 1] Let me just continue my thought process. So if there is a thrombotic threshold, it doesn't matter

how long you're going to put the vein patch. You can put a 16 millimeter vein patch, it's not going to make any difference, if you reach that thrombotic threshold. So then we come to the criticism that maybe you're selecting the cases

with good runoff, and in the good runoff, it's hard to show a difference between vein and (unintelligible) bonded with the patch, maybe. But if you are to do those terrible cases that have an isolated TPO segment, or they're all the way on the foot or the plantar arteries, that maybe the

saphenous vein will come up much better than this. What do you think? - [Dr. Peter Lin] Well, these are all great points. It's hard to discern based on a single yes or no answer. Saphenous vein has certain limitations, although I believe there's still a standard of care

in terms of conduit choice. Often times the veins are sclerotic, we're limited by vein length, so again, I brought up some points that in some patients we can only connect it to a superficial femoral, even a popliteal bypass because the vein is not long enough.

So PTFE, while it's not perfect in some scenarios, it does have advantages, because I can connect it even to the external iliac artery, I can connect at the common femoral artery, so that's that benefit. I did mention very briefly in our multi-vein analysis, the single vessel runoff is the (unintelligible) runoff.

So in those cases, you're going to have bad outcome no matter what kind of conduit you use, I do believe that, but in general we'd just use aspirin for that patient. But I believe that if we do believe there's an underlying prothrombotic condition, we would add additional anticoagulants, but that's not typical routine practice.

- [Speaker 1] Alright, I just want to add that in poor runoff situations, the vein clearly does better, and it works for a long time. We had published three years ago, on plantar arteries in branches of tibial vessels in the foot, and they did work, only with vein.

Everything else kind of failed, even with the fistulas. Yes, sir? - [Audience Member 3] I have just a quick question about the Phoenix device, a two part question. A, do you use it with a filter, or can you use it with a filter, and two, do you use it as a standalone therapy

or adjunct to a drug-eluding balloon or anything else? - [Dr. George Adams] So, in general, atherectomy is always with adjunct balloon angioplasty. In regards to the filter, especially with the Phoenix device, you have to be careful and very selective with the wire that you use,

you want to use a nitinol wire. So for a filter usually I use a free-floating filter, the NAV-6, and you can't use it over that nitinol wire, you have to use a graduated tip wire, usually a Viper or a Viper Flex. So I would select cases where you would not use

a filter specifically with this device, so if you have a long lesion or if there's any thrombotic component to it, I'd be very conscientious of using this device with that. - [Speaker 1] Thank you. Any questions from the panel?

Because I have a few questions. - [Dr. George Adams] Actually, it was I think very stimulating as to the conversation we just had, in regards to thrombotic or anticoagulants with antiplatelets, you know. Recently the COMPASS trial just came out, as well

as an E-PAD which was more or less a pilot study, showing that just taking peripheral arterial disease regardless of grafts, there seems to be a thrombotic component, and factor 10A inhibitors may have benefit in addition to antiplatelet therapy in regards to all PAD patients.

I think it's a very interesting discussion. - [Speaker 1] I have a question, Dr. Dorigo. Once you identify the high risk group of patients, is there any strategy to modify them to improve them and get them to another category? - [Dr. Walter Dorigo] Most of the perimeters we

examined were not modifiable. Age, extension of disease, coronary artery disease. Maybe one possibility is to improve the runoff status but, in concomitance with the intervention, one can try to improve the runoff score. But four out of five factors were not modifiable.

- [Speaker 1] Thank you, okay. I have one more question. So, do you do distal bypasses? - [Speaker 2] We do distal bypasses, I personally don't. I have a big group, I have three people in my group that only do distal bypasses.

- [Speaker 1] So, it says a patient in your group does not have a saphenous vein, and has a limited runoff. How will you approach there? - [Speaker 2] Well, that was a question I would want to ask both Walter and Peter.

Is there a role for composite bypasses? Because we do it quite a lot where we only have shorter parts of vein available, shorter lengths of vein available, we would do the above-knee PTFE, and then cross the knee with the vein. But I remember that last year at this meeting,

the Americans said that it's worse results, but we still do it. - [Dr. Walter Dorigo] Yes, in the registry are a crude amount, so about one, 150 composite bypasses with the short or long segmental vein and the part of PTFE graft, we use it.

And the results are not particularly better than those with the grafts, but it's likely better. - [Speaker 1] Right, I want to ask the panel, if you have the use the common femoral artery as an in-flow, and this vessel has been used

a few times before, what do you prefer to use? The external iliac, redo the groin again, or use the deep femoral as an in-flow? We'll start with Peter Lin. - [Dr. Peter Lin] I would probably go to external iliac,

because higher, it's got proximal better vessels, and it's greater diameter, all things considered. If you go deep femoral, you still got to navigate across a stenotic plaque common femoral artery. - [Speaker 1] No, it's not stenotic, it's a normal vessel. - [Dr. Peter Lin] So, I would, if all had been equal,

obviously common femoral might be better, but if common femoral's highly disease, stented and treated, and so there's a lot of scar tissue, I'd probably go with external iliac. - [Speaker 1] Okay, anybody else want to make a comment on what they preferentially use for in-flow?

- [Speaker 2] It depends what material you're going to use. If we use the vein, we go back to the common femoral, if we use prosthetic material, we would prefer to have a site where it's easier to go in and lower the risk of infection. - [Speaker 1] Right. I'll say that it depends on

the length, if I have enough length just to go deep femoral, I'll go deep femoral preferentially, but I have gone to the external iliac with a vein and have had no problem with kinking or anything, it would just make a tunnel lateral to the artery. We don't go medially because there are too many

branches there, but laterally, and you can do the anastomosis vein, and it only adds about two, three centimeters of length when you get it just above the inguinal ligament. With that, I'm going to thank the speakers, it was a great conference, and call the next moderators, please.

- Great, thank-you very much, a pleasure to be here. My disclosures. So, we've talked a little bit about obviously percutaneous and thrombectomy techniques. Obviously we have catheter-directed thrombolysis with TPA, but what happens when we can't use TPA

mechanical techniques? We've discussed several of them already in this session, I'm going to try to kind of bring them together and note the differences and how they evolved. And really look at fragmentation, rheolytic therapy, vacuum assisted devices, and vacuum and suction devices.

So when do we need these? Patients that can't tolerate thrombolysis, can't get TPA, that have a high risk of TPA, or maybe there is a situation we need a rapid response. We're trying to create flow and establish flow as much as possible and a lot of times we use this

in combination therapy if we've already hurt. What's the ideal device? I think there are multiple different characteristic's that could define the ideal device. Obviously we want it simple to use, We want it to be reproducible,

we want it to remove a lot of thrombus, but minimize blood loss and trauma to the vessels and to the blood cell. These are just some of them. There's a lot of mechanical thrombectomy devices right now on the market continuing to grow,

both in the arterial and venous system so I think this is going to be an evolution. We started really using mechanical fragmentation with a pig tail and spinning a pig tail. We used that. A lot of times the patient with severe massive pulmonary embolism.

These we're really small antidotes, small case reports. Will Kuo, looked at these in the 2009 and basically saw over all clinical success, about 86% using these mechanical devices. Then we had some that were even more automated.

All these did was break up the clot. So you have the Trerotola Device , Cleaner Device, really almost in the dialysis space. Rheolytic Throbectomy, we've already heard about. Some of how it works and the advantages. Really I think this is the first time we've saw

a system which would try to aspirate and remove some of that thrombus as it got broken up. The PEARL registry really showed for the first time, maybe we can get this done within 24 hours, can we get this done in one session? Unfortunately in this registry only about three or

four percent of patients actually had just rheolytic therapy alone without any TPA. We've discussed a little bit about the use of Ango and this type of device in terms of bradyarrhythmia's and that may be a limitation. But I think we can still use it particularly

outside of the chest. So What about suction devices? You can have a catheter, I think a catheter suction device is very limited. We use that in the arterial tree when there is a small thrombus, a small embolus, I think

we're very limited, not only in the amount of thrombus we can remove but the amount of suction we can apply. Other types like almost mechanical, very simple to use systems is the aspire device. Well you can basically create and suction a

limited area and then help you aspirate the thrombus. And then to the other extreme. We're going to hear my next speaker talk about Angiovac, again a different system, a different system requires a patient on bypass large 26 french devices.

Where we can actually go in and deal with a large amount of thrombus, like this patient had a thrombus cave on both iliac veins. And to be able to basically come with this vacuum aspiration system over wires and kind of pulling them out and you get these little canisters,

seeing what you've actually removed. Very gratifying. But takes a lot of work to get it going. We've heard a little bit about vacuum assisted with the Indigo system. With a system of creating a constant continuous vacuum.

We now have eight french catheters with incredible aspiration volume, almost 20cc's, I'm sorry you can get up to 140cc's of thrombus in a minute can be aspirated quickly. Here is a patient, 80 years old, colorectal CA. You can see the thrombus in the right leg.

There was actually a mass invading this vein. That is where we wanted to use thrombolysis, really went a head and you can see the amount of thrombus. Cleared this out with some passage. You can see this here, the separator. You started seeing thrombus especially when

its acute it kind of looks like this. It's kind of gelatinous, things that we've already seen, and then went ahead and placed a stent, dilated that stent. Had to clean up some more with the device

on top of the stent, but with a good result without needing any TPA. Other types of extraction devices we've seen the Inari device, again this is like a stent Triever device, a nitinol ring we can use this in the pulmonary arteries.

And we've already seen previous and talked about the ClotTriever device Again remove that thrombus, put it into a bag and remove it. So again, capture and removal of thrombus. And this is a solution without the need of TPA. New kid in the block the JETi device

Again very similar to aspiration Indego device, but at the same time it has a jet to macerate the clot and kind of break up the clot a little to smaller areas so we can able to thromb and take more out. I think really here what I've seen and Dr. Razavi

showed me this case. Being able to treat a patient quickly, treat that patient very quickly you can see the amount of thrombus being able to, within about an hour and 15 minutes, get all that thrombus, then create patency in that vein and he showed

some early initial good data. Over the last year we did have a paper that was presented here and published this year in the Journal of Vascular Surgery, venous and lymphatic disorders and again pulled multiple patient's, again showing that

it affective and safe. We still need better data. We need to figure out which patients are best treated with which devices and which again will be affective. Thank-you very much.

- The only disclosure is the device I'm about to talk to you about this morning, is investigation in the United States. What we can say about Arch Branch Technology is it is not novel or particularly new. Hundreds of these procedures have been performed worldwide, most of the experiences have been dominated by a cook device

and the Terumo-Aortic formerly known as Bolton Medical devices. There is mattering of other experience through Medtronic and Gore devices. As of July of 2018 over 340 device implants have been performed,

and this series has been dominated by the dual branch device but actually three branch constructions have been performed in 25 cases. For the Terumo-Aortic Arch Branch device the experience is slightly less but still significant over 160 device implants have been performed as of November of this year.

A small number of single branch and large majority of 150 cases of the double branch repairs and only two cases of the three branch repairs both of them, I will discuss today and I performed. The Aortic 3-branch Arch Devices is based on the relay MBS platform with two antegrade branches and

a third retrograde branch which is not illustrated here, pointing downwards towards descending thoracic Aorta. The first case is a 59 year old intensivist who presented to me in 2009 with uncomplicated type B aortic dissection. This was being medically managed until 2014 when he sustained a second dissection at this time.

An acute ruptured type A dissection and sustaining emergent repair with an ascending graft. Serial imaging shortly thereafter demonstrated a very rapid growth of the Distal arch to 5.7 cm. This is side by side comparison of the pre type A dissection and the post type A repair dissection.

What you can see is the enlargement of the distal arch and especially the complex septal anatomy that has transformed as initial type B dissection after the type A repair. So, under FDA Compassion Use provision, as well as other other regulatory conditions

that had to be met. A Terumo or formerly Bolton, Aortic 3-branch Arch Branch device was constructed and in December 2014 this was performed. As you can see in this illustration, the two antegrade branches and a third branch

pointing this way for the for the left subclavian artery. And this is the images, the pre-deployment, post-deployment, and the three branches being inserted. At the one month follow up you can see the three arch branches widely patent and complete thrombosis of the

proximal dissection. Approximately a year later he presented with some symptoms of mild claudication and significant left and right arm gradient. What we noted on the CT Angiogram was there was a kink in the participially

supported segment of the mid portion of this 3-branch graft. There was also progressive enlargement of the distal thoracoabdominal segment. Our plan was to perform the, to repair the proximal segment with a custom made cuff as well as repair the thoracoabdominal segment

with this cook CMD thoracoabdominal device. As a 4 year follow up he's working full time. He's arm pressures are symmetric. Serum creatinine is normal. Complete false lumen thrombosis. All arch branches patent.

The second case I'll go over really quickly. 68 year old man, again with acute type A dissection. 6.1 cm aortic arch. Initial plan was a left carotid-subclavian bypass with a TEVAR using a chimney technique. We changed that plan to employ a 3-branch branch repair.

Can you advance this? And you can see this photo. In this particular case because the pre-operative left carotid-subclavian bypass and the extension of the dissection in to the innominate artery we elected to...

utilize the two antegrade branches for the bi-lateral carotid branches and actually utilize the downgoing branch through the- for the right subclavian artery for later access to the thoracoabdominal aorta. On post op day one once again he presented with

an affective co arctation secondary to a kink within the previous surgical graft, sustaining a secondary intervention and a placement of a balloon expandable stent. Current status. On Unfortunately the result is not as fortunate

as the first case. In 15 months he presented with recurrent fevers, multi-focal CVAs from septic emboli. Essentially bacteria endocarditis and he was deemed inoperable and he died. So in conclusion.

Repair of complex arch pathologies is feasible with the 3-branch Relay arch branch device. Experience obviously is very limited. Proper patient selection important. And the third antegrade branch is useful for later thoracoabdominal access.

Thank you.

- Thank you, Ulrich. Before I begin my presentation, I'd like to thank Dr. Veith so kindly, for this invitation. These are my disclosures and my friends. I think everyone knows that the Zenith stent graft has a safe and durable results update 14 years. And I think it's also known that the Zenith stent graft

had such good shrinkage, compared to the other stent grafts. However, when we ask Japanese physicians about the image of Zenith stent graft, we always think of the demo version. This is because we had the original Zenith in for a long time. It was associated with frequent limb occlusion due to

the kinking of Z stent. That's why the Spiral Z stent graft came out with the helical configuration. When you compare the inner lumen of the stent graft, it's smooth, it doesn't have kink. However, when we look at the evidence, we don't see much positive studies in literature.

The only study we found was done by Stephan Haulon. He did the study inviting 50 consecutive triple A patients treated with Zenith LP and Spiral Z stent graft. And he did two cases using a two iliac stent and in six months, all Spiral Z limb were patent. On the other hand, when you look at the iliac arteries

in Asians, you probably have the toughest anatomy to perform EVARs and TEVARs because of the small diameter, calcification, and tortuosity. So this is the critical question that we had. How will a Spiral Z stent graft perform in Japanese EIA landing cases, which are probably the toughest cases?

And this is what we did. We did a multi-institutional prospective observational study for Zenith Spiral Z stent graft, deployed in EIA. We enrolled patients from June 2017 to November 2017. We targeted 50 cases. This was not an industry-sponsored study.

So we asked for friends to participate, and in the end, we had 24 hospitals from all over Japan participate in this trial. And the board collected 65 patients, a total of 74 limbs, and these are the results. This slide shows patient demographics. Mean age of 77,

80 percent were male, and mean triple A diameter was 52. And all these qualities are similar to other's reporting in these kinds of trials. And these are the operative details. The reason for EIA landing was, 60 percent had Common Iliac Artery Aneurysm.

12 percent had Hypogastric Artery Aneurysm. And 24 percent had inadequate CIA, meaning short CIA or CIA with thrombosis. Outside IFU was observed in 24.6 percent of patients. And because we did fermoral cutdowns, mean operative time was long, around three hours.

One thing to note is that we Japanese have high instance of Type IV at the final angio, and in our study we had 43 percent of Type IV endoleaks at the final angio. Other things to notice is that, out of 74 limbs, 11 limbs had bare metal stents placed at the end of the procedure.

All patients finished a six month follow-up. And this is the result. Only one stenosis required PTA, so the six months limb potency was 98.6 percent. Excellent. And this is the six month result again. Again the primary patency was excellent with 98.6 percent. We had two major adverse events.

One was a renal artery stenosis that required PTRS and one was renal stenosis that required PTA. For the Type IV index we also have a final angio. They all disappeared without any clinical effect. Also, the buttock claudication was absorbed in 24 percent of patients at one month, but decreased

to 9.5 percent at six months. There was no aneurysm sac growth and there was no mortality during the study period. So, this is my take home message, ladies and gentlemen. At six months, Zenith Spiral Z stent graft deployed in EIA was associated with excellent primary patency

and low rate of buttock claudication. So we have most of the patients finish a 12 month follow-up and we are expecting excellent results. And we are hoping to present this later this year. - [Host] Thank you.

- Thank you for the opportunity to present this arch device. This is a two module arch device. The main model comes from the innominated to the descending thoracic aorta and has a large fenestration for the ascending model that is fixed with hooks and three centimeters overlapping with the main one.

The beginning fenestration for the left carotid artery was projected but was abandoned for technical issue. The delivery system is precurved, preshaped and this allows an easy positioning of the graft that runs on a through-and-through wire from the

brachial to the femoral axis and you see here how the graft, the main model is deployed with the blood that supported the supraortic vessels. The ascending model is deployed after under rapid pacing.

And this is the compilation angiogram. This is a case from our experience is 6.6 centimeters arch and descending aneurysm. This is the planning we had with the Gore Tag. at the bottom of the implantation and these are the measures.

The plan was a two-stage procedure. First the hemiarch the branching, and then the endovascular procedure. Here the main measure for the graph, the BCT origin, 21 millimeters, the BCT bifurcation, 20 millimeters,

length, 30 millimeters, and the distal landing zone was 35 millimeters. And these are the measures that we choose, because this is supposed to be an off-the-shelf device. Then the measure for the ascending, distal ascending, 35 millimeters,

proximal ascending, 36, length of the outer curve of 9 centimeters, on the inner curve of 5 centimeters, and the ascending model is precurved and we choose a length between the two I cited before. This is the implantation of the graft you see,

the graft in the BCT. Here, the angiography to visualize the bifurcation of the BCT, and the release of the first part of the graft in the BCT. Then the angiography to check the position. And the release of the graft by pushing the graft

to well open the fenestration for the ascending and the ascending model that is released under cardiac pacing. After the orientation of the beat marker. And finally, a kissing angioplasty and this is the completion and geography.

Generally we perform a percutaneous access at auxiliary level and we close it with a progolide checking the closure with sheet that comes from the groin to verify the good occlusion of the auxiliary artery. And this is the completion, the CT post-operative.

Okay. Seven arch aneurysm patients. These are the co-morbidities. We had only one minor stroke in the only patient we treated with the fenestration for the left carotid and symptomology regressed completely.

In the global study, we had 46 implantations, 37 single branch device in the BCT, 18 in the first in men, 19 compassionate. These are the co-morbidities and indications for treatment. All the procedures were successful.

All the patients survived the procedure. 10 patients had a periscope performed to perfuse the left auxiliary artery after a carotid to subclavian bypass instead of a hemiarch, the branching. The mean follow up for 25 patients is now 12 months.

Good technical success and patency. We had two cases of aneurysmal growth and nine re-interventions, mainly for type II and the leak for the LSA and from gutters. The capilomiar shows a survival of 88% at three years.

There were three non-disabling stroke and one major stroke during follow up, and three patients died for unrelated reasons. The re-intervention were mainly due to endo leak, so the first experience was quite good in our experience and thanks a lot.

- This is from some work in collaboration with my good friend, Mike Dake. And, a couple of years of experience at Stanford now. First described by Kazy? years ago. This technical note of using multiple main-body endographs in a sandwich formation.

Up at the top but, then yielding multiple branches to get out to the visceral vessels and leaving one branch for a bifurcated graft. We've sort of modified it a little bit and generally either use multiple

grafts in order to create a branch the celiac and SMA. Left the celiac sometimes for a chimney, but the strategy really has been in one of the limbs to share both renals and the limb that goes down to the legs. We noticed early on that this really was not for

non-operative candidates, only for urgent cases and we recognize that the visceral branches were the most important to be in their own limb. I'll just walk you through a case. 6.8 centimeter stent for foraco above

the prior opened repair. The plan drawn out here with multiple main bodies and a second main body inside in order to create the multiple branches. The first piece goes in. It's balloon molded at the level of pulmonary

vein with enough length so that the ipsalateral limb is right next to the celiac. And we then, from above get into that limb and down into the celiac vessel and extend with either a limb or a viabahn. Next, we deploy a second main body inside

of the gate, thus creating now another two limbs to work through. And then through that, extend in its own branch a limb to the SMA. This was an eight by 79 vbx. Then we've got a third limb to go through.

We put a cuff that measures about 14. This is the math so that the double renal snorkle plus the main body fills up this hole. Now, double sheath access from above, looking for both renals. Sheaths out into both renals with viabahns

inside of that. Deployment of the bottom device and then a final angiogram with a little bit of a gutter that we often see when we have any kind of parallel graft configuration. Here's the post-op CT scan wherein

that limb is the two shared renals with the leg. This is the one year post-op with no endo leaks, successful exclusion of this. Here's another example of one of an eight and a half centimeter stent three thorico similar strategy, already with an occluded

celiac. Makes it a little bit easier. One limb goes down to the superior mesenteric artery and then the other limb then is shared again bilateral renals in the lower main body. Notice in this configuration you can get all the way up to the top then by putting a thoracic component

inside of the bifurcated subabdominal component. There's the final CT scan for that. We've spent some time looking at the different combinations of how these things will fill up to minimize the gutters through some more work. In collaboration with some friends in Kampala.

So we've treated 21 patients over the last couple of years. 73 years of age, 48 percent female usual comorbid factors. Oh, I thought I had more data there to show you. O.K. I thought this was a four minute talk.

Look at that. I'm on time. Octopus endovascular strategy is a feasible off the shelf solution for high risk patients that can't undergo open repair. You know obviously, sort of in this forum and coming to this meeting we see what's

available outside of the U.S. and I certainly am awaiting clinical trial devices that will have purpose specific teacher bi-graphs. The end hospital morbidity has still been high, at four percent. The one year survival of 71 percent in this select

group of 21 patients is acceptable. Paraplegia is still an issue even when we stage them and in this strategy you can stage them by just doing the top part plus the viscerals first and leaving the renals for another day. And branch patency thus far has been

in the short term similar to the purpose specific graft as well as with the parallel graft data. Thank you.

- Good afternoon, Dr. Veith, organizer. Thank you very much for the kind invitation. I have nothing to disclose. In the United States, the most common cause of mortality after one year of age is trauma. So, thankfully the pediatric vascular trauma

is only a very small minority, and it happens in less that 1% of all the pediatric traumas. But, when it happens it contributes significantly to the mortality. In most developed countries, the iatrogenic

arterial injuries are the most common type of vascular injuries that you have in non-iatrogenic arterial injuries, however are more common in war zone area. And it's very complex injuries that these children suffer from.

In a recent study that we published using the national trauma data bank, the mortality rate was about 7.9% of the children who suffer from vascular injuries. And the most common mechanism of injury were firearm and motor vehicle accidents. In the US, the most common type of injury is the blunt type

of injury. As far as the risk factors for mortality, you can see some of them that are significantly affecting mortality, but one of them is the mechanism of injury, blunt versus penetrating and the penetrating is the risk factor for

mortality. As far as the anatomical and physiological consideration for treatment, they are very similar to adults. Their injury can cause disruption all the way to a spasm, or obstruction of the vessel and for vasiospasm and minimal disruption, conservative therapy is usually adequate.

Sometimes you can use papevrin or nitroglycerin. Of significant concern in children is traumatic AV fissure that needs to be repaired as soon as possible. For hard signs, when you diagnose these things, of course when there is a bleeding, there is no question that you need to go repair.

When there are no hard signs, especially in the blunt type of injuries, we depend both on physical exams and diagnostic tools. AVI in children is actually not very useful, so instead of that investigators are just using what is called an Injured Extremity Index, which you measure one leg

versus the other, and if there is also less than 0.88 or less than 0.90, depending on the age of the children, is considered abnormal. Pulse Oximetry, the Duplex Ultrasound, CTA are all very helpful. Angiography is actually quite risky in these children,

and should be avoided. Surgical exploration, of course, when it's needed can give very good results. As far as the management, well they are very similar to adults, in the sense that you need to expose the artery, control the bleeding, an then restore circulation to the

end organ. And some of the adjuncts that are using in adult trauma can be useful, such as use of temporary shunts, that you can use a pediatric feeding tube, heparin, if there are no contraindications, liberal use of fasciotomy and in the vascular technique that my partner, Dr. Singh will be

talking about. Perhaps the most common cause of PVI in young children in developed countries are iatrogenic injuries and most of the time they are minimal injuries. But in ECMO cannulation, 20-50% are injuries due to

ECMO have been reported in both femoral or carotid injuries. So, in the centers are they are doing it because of the concern about limb ischemia, as well as cognitive issues. They routinely repair the ECMO cannulation site.

For non-iatrogenic types, if is very common in the children that are above six years of age. Again, you follow the same principal as adult, except that these arteries are severely spastic and interposition graft must accommodate both axial and radial growths of these arteries, as well as the limb that it's been

repaired in. Primary repair sometimes requires interrupted sutures and Dr. Bismuth is going to be talking about some of that. Contralateral greater saphenous vein is a reasonable option, but this patient needs to be followed very, very closely.

The most common type of injury is upper extremity and Dr. McCurdy is going to be talking about this. Blunt arterial injury to the brachial artery is very common. It can cause ischemic contracture and sometimes amputation.

In the children that they have no pulse, is if there are signs of neurosensory deficit and extremity is cold, exploration is indicated, but if the extremity is pulseless, pink hand expectant treatment is reasonable. As far as the injuries, the most common, the deadliest injuries are related to the truncal injuries and the

mechanism severity of this injury dictates the treatment. Blunt aortic injuries are actually quite uncommon and endovascular options are limited. This is an example of one that was done by Dr Veith and you can see the arrow when the stent was placed and then moved.

So these children, the long-term results of endovascular option is unknown. So in summary, you basically follow many tenets of adult vascular trauma. Special consideration for repair has to do with the fact that you need to accommodate longitudinal

and radial growth and also endovascular options are limited. Ultimately, you need a collaborative effort of many specialists in taking care of these children. Thank you.

- Thank you (mumbles). The purpose of deep venous valve repair is to correct the reflux. And we have different type of reflux. We know we have primary, secondary, the much more frequent and the rear valve agenesia. In primary deep venous incompetence,

valves are usually present but they are malfunctioning and the internal valvuloplasty is undoubtedly the best option. If we have a valve we can repair it and the results are undoubtedly the better of all deep vein surgery reconstruction

but when we are in the congenital absence of valve which is probably the worst situation or we are in post-thrombotic syndrome where cusps are fully destroyed, the situation is totally different. In this situation, we need alternative technique

to provide a reflux correction that may be transposition, new valve or valve transplants. The mono cuspid valve is an option between those and we can obtain it by parietal dissection. We use the fibrotic tissue determined by the

sickening of the PTS event obtaining a kind of flap that we call valve but as you can realize is absolutely something different from a native valve. The morphology may change depending on the wall feature and the wall thickness

but we have to manage the failure of the mono cuspid valve which is mainly due to the readhesion of the flap which is caused by the fact that if we have only a mono cuspid valve, we need a deeper pocket to reach the contralateral wall so bicuspid valve we have

smaller cusps in mono cuspid we have a larger one. And how can we prevent readhesion? In our first moment we can apply a technical element which is to stabilize the valve in the semi-open position in order not to have the collapse of the valve with itself and then we had decide to apply an hemodynamic element.

Whenever possible, the valve is created in front of a vein confluence. In this way we can obtain a kind of competing flow, a better washout and a more mobile flap. This is undoubtedly a situation that is not present in nature but helps in providing non-collapse

and non-thrombotic events in the cusp itself. In fact, if we look at the mathematical modeling in the flow on valve you can see how it does work in a bicuspid but when we are in a mono cuspid, you see that in the bottom of the flap

we have no flow and here there is the risk of thrombosis and here there is the risk of collapse. If we go to a competing flow pattern, the flap is washed out alternatively from one side to the other side and this suggest us the idea to go through a mono cuspid

valve which is not just opens forward during but is endovascular and in fact that's what we are working on. Undoubtedly open surgery at the present is the only available solution but we realized that obviously to have the possibility

to have an endovascular approach may be totally different. As you can understand we move out from the concept to mimic nature. We are not able to provide the same anatomy, the same structure of a valve and we have to put

in the field the possibility to have no thrombosis and much more mobile flap. This is the lesson we learn from many years of surgery. The problem is the mobile flap and the thrombosis inside the flap itself. The final result of a valve reconstruction

disregarding the type of method we apply is to obtain an anti-reflux mechanism. It is not a valve, it is just an anti-reflux mechanism but it can be a great opportunity for patient presenting a deep vein reflux that strongly affected their quality of life.

Thank you.

- Thank you very much and thank you Dr. Veith for the kind invite. Here's my disclosures, clearly relevant to this talk. So we know that after EVAR, it's around the 20% aortic complication rate after five years in treating type one and three Endoleaks prevents subsequent

secondary aortic rupture. Surveillance after EVAR is therefore mandatory. But it's possible that device-specific outcomes and surveillance protocols may improve the durability of EVAR over time. You're all familiar with this graph for 15 year results

in terms of re-intervention from the EVAR-1 trials. Whether you look at all cause and all re-interventions or life threatening re-interventions, at any time point, EVAR fares worse than open repair. But we know that the risk of re-intervention is different

in different patients. And if you combine pre-operative risk factors in terms of demographics and morphology, things are happening during the operations such as the use of adjuncts,

or having to treat intro-operative endoleak, and what happens to the aortic sac post-operatively, you can come up with a risk-prediction tool for how patients fare in the longer term. So the LEAR model was developed on the Engage Registry and validated on some post-market registries,

PAS, IDE, and the trials in France. And this gives a predictive risk model. Essentially, this combines patients into a low risk group that would have standard surveillance, and a higher risk group, that would have a surveillance plus

or enhanced surveillanced model. And you get individual patient-specific risk profiles. This is a patient with around a seven centimeter aneurysm at the time of repair that shows sac shrinkage over the first year and a half, post-operatively. And you can see that there's really a very low risk

of re-intervention out to five years. These little arrow bars up here. For a patient that has good pre-operative morphology and whose aneurysm shrinks out to a year, they're going to have a very low risk of re-intervention. This patient, conversely, had a smaller aneurysm,

but it grew from the time of the operation, and out to two and a half years, it's about a centimeter increase in the sac. And they're going to have a much higher risk of re-intervention and probably don't need the same level of surveillance as the first patient.

and probably need a much higher rate of surveillance. So not only can we have individualized predictors of risk for patients, but this is the regulatory aspect to it as well.

Multiple scenario testing can be undertaken. And these are improved not only with the pre-operative data, but as you've seen with one-year data, and this can tie in with IFU development and also for advising policy such as NICE, which you'll have heard a lot about during the conference.

So this is just one example. If you take a patient with a sixty-five millimeter aneurysm, eighteen millimeter iliac, and the suprarenal angle at sixty degrees. If you breach two or more of these factors in red, we have the pre-operative prediction.

Around 20% of cases will be in the high risk group. The high risk patients have about a 50-55% freedom from device for related problems at five years. And the low risk group, so if you don't breach those groups, 75% chance of freedom from intervention.

In the green, if you then add in a stent at one year, you can see that still around 20% of patients remain in the high risk group. But in the low risk group, you now have 85% of patients won't need a re-intervention at five years,

and less of a movement in the high risk group. So this can clearly inform IFU. And here you see the Kaplan-Meier curves, those same groups based pre-operatively, and at one year. In conclusion, LEAR can provide

a device specific estimation of EVAR outcome out to five years. It can be based on pre-operative variables alone by one year. Duplex surveillance helps predict risk. It's clearly of regulatory interest in the outcomes of EVAR.

And an E-portal is being developed for dissemination. Thank you very much.

- I'd like to thank Larry and John for the opportunity to speak today. This really is kind of an exciting time in Vascular Access 'cause you know this whole session's devoted to all the new tools and technologies, and they're really a lot of different options

that are available to us now to create functioning fistulas in patients. Those are my disclosures. I just want to mention one thing, when I was asked to give this talk, the name of the device was the Everlink device then,

and that was first developed by TBA Medical at Austin, Texas. Eventually the company was bought by Bard, and then Beckett Dickinson bought Bard, and then they changed the name of the device to the WaveLinq device,

just so that we're all on the same page here. The basic gyst of this system basically it's a two-catheter system, it involves punctures in the brachial artery and brachial vein above the elbow over wires, the catheters are then aligned

in the ulnar artery and ulnar vein. The venous catheter has an RF electrode on it, the arterial component has a ceramic foot plate, and there's rare earth magnets in the catheters that help them align in the artery and vein. They'll coapt, you deploy the foot plate,

and then you fire the RF energy from the RF generator, and the RF energy then creates a four millimeter hole between the artery and vein. This is just what it looks like under fluoroscopy, this is the arterial catheter going in here's the footplate here

this is the venous catheter then being directed and you can see the magnets on these they look like Lincoln Logs they'll kind of line up. You rotate the catheters 'til the foot plate aligns, you do some flyovers with the II make sure everything's lined up,

and then you create the fistula with the RF energy. Then this is just what Fistulagram looks like once the fistula's created. At the completion of that, for this device we then place coils, occluding coils, in the deep vein which was just beyond the sheath

where we accessed the brachial vein. And by putting those plugs in there, coils in there, It helps to direct the flow up to through the superficial veins which we cannulated for dialysis, and much like the other device

that Dr. Malia was talking before, this creates essentially a split vein fistula, it's going to mature both the cephalic and basilic if those veins are available through that from the perforator coming on out. This is just what it looks like you know,

this was in some early studies in the animal model, you can see that it creates exactly a four millimeter hole between the artery and vein. Eventually this will re-endothelialize they had endothelialization at 30 days. So really the nice thing about it is

it standardizes the size of the arteriotomy because it makes exactly a four millimeter fistula. Now, as I mention this is created at the level of the ulnar artery and ulnar vein, so the requirements basically to do this you need a adequate size obviously ulnar artery and vein,

but the big component is to have that adequate perforator vein that's going to help feed the superficial veins to mature that fistula. And then it's just creating a side to side fistula between the ulnar artery and vein.

This is just a composite of all the data that's been collected on the device so far so this is what the global registry looks like. The FLEX study was kind of the first studies in man. The NEAT trial was run in the Canada and the UK, that was one of the earlier trials.

Then there's a post-market registry, uh, in Europe that's being run now. The EASE trial is the trial with the Four French device and I'll share a little bit about that at one of the slides at the end. But basically pull all the data from this

there's almost 157 patients that they collected data on. And, you can see that with this the primary patency, or the primary patency's on at 75 percent, and the accumulative patency's almost 80 percent, and then the number of fistulas that were cannulated at six months successfully with two needles was 75 percent.

If you look at some of the interventions that've had to be done it really seems to be a lower number of interventions that have to be done to get a mature functioning fistula, uh, using this device. I just want to point out a couple things on this slide,

there was never any requirement for angioplasty at the uh, the ulnar artery the ulnar vein anastomosis, and there was, you know, with these embolizations that were performed, 12 of these were performed on patients prior to incorporating that into the procedure itself,

so right now in the IFU it says that the deep veins should be coiled to help direct that flow up into the superficial veins. Now as, uh, was alluded to earlier with the Ellipsys device this kind of falls somewhere between, uh, the radiocephalic fistula and a brachiocephalic fistula,

and again comparing these two devices basically you're creating, this is the Ellipsys device is radial-radial, and this device is really ulnar-ulnar, but again you're creating that split-flow fistula it's going to allow flow both up

into the basilic and cephalic veins. So, where can this be used? It can be used for primary access creation so that's the first option to provide a patient with a functioning fistula. It can be a secondary option to radiocephalic fistula,

or those that have failed the radiocephalic fistula, and it also is an alternative to surgery so there are patients that may not want to have open surgery to have a fistula created, and this obviously provides an option for those patients. In the UK now they're using it to condition veins,

so they'll create the fistula hoping to condition the cephalic and basilic veins to allow them to become usable for dialysis, and they're also using it in patients that have no superficial veins actually using it to mature the brachial vein

or the deeper veins, uh, and then superficializing the brachial vein to create a native fistula for patients who don't have adequate superficial veins. Now I mentioned the Four French device and what the Four French device allows is basically access

from a lot of different points. So now because it's a smaller device, we can place it, if the vein and artery are large enough, it can be placed at the wrists, so radial-radial fistula, so you come in from the wrist, put both catheters up, create the fistula at the radial-radial,

you can do it from the ulnar-ulnar, so it's just two catheters up from the wrist. And these cases are nice, the other option is you can come arterial from the wrist and you can come from the vein at the top, match up the catheters in a parallel

and create that fistula at the ulnar-ulnar level. And the nice thing about this is it really makes managing the puncture very easy you just put a TR band on 'em, and then you're good to go. So it really kind of opens up a lot of different options for creating fistulas.

So in summary this device seems to create a functional fistula without the need for open surgery. It has very good primary and cumulative patencies and seems to take fewer interventions to maintain and mature the functioning fistula, and this may add another tool that we have to create

functioning fistulas in patients who are on dialysis. So thank you very much.

- Thank you Mr Chairman, ladies and gentlemen. These are my disclosure. Open repair is the gold standard for patient with arch disease, and the gupta perioperative risk called the mortality and major morbidity remain not negligible.

Hybrid approach has only slightly improved these outcomes, while other off-the-shelf solution need to be tested on larger samples and over the long run. In this scenario, the vascular repair would double in the branch devices as emerging, as a tentative option with promising results,

despite addressing a more complex patient population. The aim of this multi-center retrospective registry is to assess early and midterm results after endovascular aortic arch repair. using the single model of doubling the branch stent graft in patient to fit for open surgery.

All patient are treated in Italy, with this technique. We're included in this registry for a total of 24 male patient, fit for open surgery. And meeting morphological criteria for double branch devices.

This was the indication for treatment and break-down by center, and these were the main end points. You can see here some operative details. Actually, this was theo only patient that did not require the LSA

re-revascularization before the endovascular procedure, because the left tibial artery rising directly from the aortic arch was reattached on the left common carotid artery. You can see here the large window in the superior aspect of the stent graft

accepting the two 13 millimeter in the branches, that are catheterized from right common carotid artery and left common carotid artery respectively. Other important feature of this kind of stent graft is the lock stent system, as you can see, with rounded barbs inside

the tunnels to prevent limb disconnection. All but one patient achieved technical success. And two of the three major strokes, and two retrograde dissection were the cause of the four early death.

No patient had any type one or three endoleak. One patient required transient dialysis and four early secondary procedure were needed for ascending aorta replacement and cervical bleeding. At the mean follow-up of 18 months,

one patient died from non-aortic cause and one patient had non-arch related major stroke. No new onset type one or three endoleak was detected, and those on standard vessel remained patent. No patient had the renal function iteration or secondary procedure,

while the majority of patients reported significant sac shrinkage. Excluding from the analysis the first six patients as part of a learning curve, in-hospital mortality, major stroke and retrograde dissection rate significant decrease to 11%, 11% and 5.67%.

Operative techniques significantly evolve during study period, as confirmed by the higher use of custom-made limb for super-aortic stenting and the higher use of common carotid arteries

as the access vessels for this extension. In addition, fluoroscopy time, and contrast median's significantly decrease during study period. We learned that stroke and retrograde dissection are the main causes of operative mortality.

Of course, we can reduce stroke rate by patient selection excluding from this technique all those patient with the Shaggy Aorta Supra or diseased aortic vessel, and also by the introduction and more recent experience of some technical points like sequentIal clamping of common carotid arteries

or the gas flushing with the CO2. We can also prevent the retrograde dissection, again with patient selection, according to the availability of a healthy sealing zone, but in our series, 6 of the 24 patients

presented an ascending aorta larger than 40 millimeter. And on of this required 48-millimeter proximal size custom-made stent graft. This resulted in two retrograde dissection, but on the other hand, the availability on this platform of a so large proximal-sized,

customized stent graft able to seal often so large ascending aorta may decrease the incidence of type I endoleak up to zero, and this may make sense in order to give a chance of repair to patients that we otherwise rejected for clinical or morphological reasons.

So in conclusion, endovascular arch repair with double branch devices is a feasible approach that enrich the armamentarium for vascular research. And there are many aspects that may limit or preclude the widespread use of this technology

with subsequent difficulty in drawing strong conclusion. Operative mortality and major complication rates suffer the effect of a learning curve, while mid-term results of survival are more than promising. I thank you for your attention.

Disclaimer: Content and materials on Medlantis are provided for educational purposes only, and are intended for use by medical professionals, not to be used self-diagnosis or self-treatment. It is not intended as, nor should it be, a substitute for independent professional medical care. Medical practitioners must make their own independent assessment before suggesting a diagnosis or recommending or instituting a course of treatment. The content and materials on Medlantis should not in any way be seen as a replacement for consultation with colleagues or other sources, or as a substitute for conventional training and study.